• 제목/요약/키워드: surge

Search Result 1,831, Processing Time 0.025 seconds

The Performance Characteristics of Anti-Surge Devices for High Head Cooling Water Systems in 1,000 MW Thermal Power plants (고수두 1,000 MW 석탄화력발전소 냉각수계통 수격방지장치의 성능특성)

  • Kim, Keun-Pil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.36-42
    • /
    • 2019
  • In recent, according to the tightening of environment regulation policy, the height of the site of the power plant is increased and the length of the cooling water pipe is increased. This has a serious impact on the stability of the plant. This study analyzes the transient phenomenon using LIQT 7.2, an unsteady state one-dimensional analysis software, to secure the stability of 1,000 MW high-capacity coal-fired power plant cooling water system with high head. To prevent water hammer, The effects on performance characteristics were predicted by individual and combination application. The surge pressure of the cooling water which occurs when the pump was stopped without installing the anti-surge devices was the largest at the pump outlet side. The most effective and simple way to reduce surge pressure in these cooling water systems is to combine a vacuum breaker with a hydraulic non-return valve, which is an essential device for pump protection.

Surge Control of Turbofan Engine Compressor with the Variable Inlet Guide Vane (가변 안내익을 이용한 터보팬 엔진 압축기의 서지 제어)

  • Bae, Kyoungwook;Kim, Sangjo;Han, Dongin;Min, Chanoh;Lee, Daewoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.7
    • /
    • pp.539-546
    • /
    • 2013
  • Surge phenomenon can be occurred in a compressor when compressor performance of turbofan engine for an aircraft is changed considerably in a short time on the cases like take-off phase and changing of RPM from idle to maximum, because performance of aircraft engine is changed suddenly. This study is aimed to avoid surge in a compressor. Dynamic simulation in a compressor is modeled by simulink in specific condition. Fuel flow is control input, rpm and air mass flow are expressed in terms of transfer function. Surge margin is obtained by using compressor performance map from NPSS. VIGV(Variable Inlet Guide Vane) is controlled by PD controller with difference between surge margin and reference. Finally this paper verifies IGV can prevent surge phenomenon in a compressor.

Web Service System for GIS-based Storm-surge Visualization (GIS기반 폭풍해일 시각화를 통한 웹 서비스 시스템 구축)

  • Kim, Jin-Ah;Park, K.S.;Kwon, Jae-Il
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.611-614
    • /
    • 2009
  • Understanding the severity of the typhoon-induced storm-surge helps in planning reaction and in preventing further disaster. Natural disasters due to the storm-surge are predictable from accurate observations and forecasts from numerical simulations. What we can do is to make intelligent effort to minimize the loss due to the disaster to the most extent with the technology of early warning, forecast and prevention activity. In this paper, we propose the design of GIS-based Web Service System to visualize the time-varying storm-surge's height and wind field data effectively with 3 different kinds of resolution for predict and prevent storm-surge disasters. This system is one of the efforts to provide the storm-surge forecast service to general public and share two-way more helpful information to coastal resident through the Internet.

  • PDF

Electrical Properties of 18[kV] ZnO Surge Arrester Stressed by the Mixed DC and 60[Hz] AC Voltages (직류+60[Hz]교류 중첩전압에 대한 18[kV] ZnO 피뢰기의 전기적 특성)

  • Lee, Su-Bong;Lee, Seung-Ju;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.66-72
    • /
    • 2007
  • This paper describes the characteristics of power loss and leakage currents flowing through new and used 18[kV] zinc oxide(ZnO) surge arrester under the mixed DC and AC voltages. The mixed DC and AC voltage generator of 50[kV] peak was designed and fabricated. The I-V curves of ZnO surge arrester were measured as a function of the voltage ratio K. The I-V curves under the mixed DC and AC voltages lay between the pure DC and AC characteristics, and the cross-over phenomenon in both I-V curves and R-V curves was observed at the low current region. As a result, the increase of DC component in the mixed voltages causes the increase of resistive component of total leakage current of ZnO surge arrester. Also, in the case of same applied voltage, the leakage current flowing through the used ZnO surge arrester was higher than that of the new ZnO surge arrester.

Transient Overvoltages of Communication Equipment Depending on the Grounding Method of SPD (SPD 접지방식에 따른 통신기기의 과도위험전압)

  • Eom, Ju-Hong;Lee, Tae-Hyung;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.130-138
    • /
    • 2008
  • The tendency of lightning surge to propagate is a eared variously depend on the power system and subject equipment of protection. However, looking into the subject equipment with the lightning surge, the invasion route of lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the route of lightning surge incoming from between the communication lines, the communication line and the ground in addition to the power lines. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground and bypass arrester ground for safety improvement in power lines.

Investigation of Feline Ovulation Time after LH Surge Induced by hCG Injection in Superovulation

  • Jeon, Kyo-Hee;Kim, Seung-Hwan;Lee, Jin-Goo;Kim, Ghang-Yong;Oh, Seung-Kyu;Malaweera, Don Buddika Oshadi;Ramachandra, Sisitha;Yoon, Ki-Young;Shin, Sang-Tae;Cho, Jong-Ki
    • Journal of Embryo Transfer
    • /
    • v.29 no.2
    • /
    • pp.177-182
    • /
    • 2014
  • Feline ovulation time after LH surge have not been defined because its LH surge is occurred by several times of coital vaginal induction and cat has relatively longer time between LH surge and ovulation compared with other mammalian species. This study was performed to investigate the feline ovulation time after LH surge that was induced by hCG injection for superovulation with PMSG. For superovulation, all cats were received an initial injection of PMSG (200 IU, i.m.) followed 80 hrs later with an injection of hCG (200 IU, i.m.). And then, sampling of both ovaries was surgically performed at each 6 different times (10, 18, 22, 26, 29, and 32 hrs) after hCG injection. Cumulus-oocyte-complexes (COCs) were collected from 2 sides of oviducts and ovaries were fixed for ovarian histology. Total 38 COCs were collected only at hCG 32 hrs and no COCs were shown at earlier 5 times. However, in the ovarian histology, corpus haemorrhagicum or corpus luteum was not shown in all groups including ovary at hCG 32 hrs that COCs were collected. In conclusion, it was suggested that feline ovulation was occurred at 29~32 hrs after LH surge and taken relatively long time for CL formation after ovulation.

Choked Surge in a Cavitating Turbopump Inducer

  • Watanabe, Toshifumi;Kang, Dong-Hyuk;Cervone, Angelo;Kawata, Yutaka;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.64-75
    • /
    • 2008
  • During an experimental investigation on a 3-bladed and a 4-bladed axial inducer, a severe surge instability was observed in a range of cavitation number where the blade passage is choked and the inducer head is decreased from noncavitating value. The surge was stronger for the 4-bladed inducer as compared with a 3-bladed inducer with the same inlet and outlet blade angles. For the 4-bladed inducer, the head decreases suddenly as the cavitation number is decreased. The surge was observed after the sudden drop of head. This head drop was found to be associated with a rapid extension of tip cavity into the blade passage. The cause of surge is attributed to the decrease of the negative slope of the head-flow rate performance curve due to choke. Assuming that the difference between the 3 and 4-bladed inducers is caused by the difference of the blockage effects of the blade, a test was carried out by thickening the blades of the 3-bladed inducer. However, opposite to the expectations, the head drop became smoother and the instability disappeared on the thickened blade inducer. Examination of the pressure distribution on both inducers could not explain the difference. It was pointed out that two-dimensional cavitating flow analyses predict smaller breakdown cavitation number at higher flow rates, if the incidence angle is smaller than half of the blade angle. This causes the positive slope of the performance curve and suggests that the choked surge as observed in the present study might occur in more general cases.

Characteristics of Atmospheric Circulation and Heat Source related to Winter Cold Surge in Korea (한반도 겨울철 한파와 관련된 대기 순환과 열원의 특성)

  • Kim Maeng-Ki;Shin Sung-Chul;Lee Woo-Seop
    • Journal of the Korean earth science society
    • /
    • v.26 no.6
    • /
    • pp.560-572
    • /
    • 2005
  • This study investigates the characteristics of atmospheric circulation and the heat source $(Q_1)$ related to the winter cold surge in Korea from 1979 to 1999. The occurrence frequency of cold surge is about one event per year and $60\%$ of the total events occurred during the former period, before 1989. During the cold surge, the pressure pattern shows more dominant east-west dipole circulation pattern in the lower troposphere and the effect of upper level trough is stronger than normal cases. Temperature falling pattern over Korea shows that the pattern opposite to the temperature structure over Lake Baikal and temperature change has opposite signs between the low-middle level and upper level, with the boundary at 400 hPa. The analysis of heat source shows that atmospheric cooling by cold advection during the cold surge is balanced by adiabatic warming due to downward motion, indicating that the movement path of cold core is associated with that of heat sink. Therefore, the movement mechanism of the heat source and sink should be well known for understanding the maintenance mechanism of cold surge and predicting cold surges.

Patterns of Ovarian Changes Associated with Surge Mode Secretion of Gonadotropin in Dairy Cows with Cyclic Estrous Cycle

  • Kim, Seung-Joon
    • Journal of Embryo Transfer
    • /
    • v.33 no.4
    • /
    • pp.297-304
    • /
    • 2018
  • The purpose of the present study was to determine the elaborate characteristics of ovarian changes including follicles and corpus luteum, and hormonal patterns of gonadotropin surge mode secretions during the normal consecutive estrous cycle in three dairy cows. Non-lactating and multiparous Holstein cows (n=3) used as experimental animals. The cows were assigned to examine the relationship among ovarian changes (follicle, corpus luteum), ovarian steroids (estradiol, progesterone) and gonadotropin (LH, FSH) surge mode secretion during the successive estrous cycles by rectal palpation, ultrasonography and hormonal assay. The mean length of the estrous cycle for the three cows was $23.1{\pm}1.44days$ (${\pm}SEM$), with a range of 20-28 days. In six estrous cycles, the number of two follicular waves, three follicular waves and four follicular waves was 2, 3 and 1, respectively. The sequential ultrasonographic monitoring showed that the corpus luteum with ${\geq}10mm$ in diameter detected from Day 2 (Day 0 is ovulation) in six estrous cycles of all cows. Preovulatory increases in estradiol concentration reached $10.36{\pm}1.10pg/ml$ on the 2 days before ovulation of the last dominant follicle. All cows exhibited a preovulatory rise in estradiol concentration followed by a typical preovulatory LH and FSH surge. The mean interval from the peak of LH/FSH surge to ovulation of the last dominant follicle was $31.3{\pm}1.76h$ (${\pm}SEM$). In these results, each dairy cow showed that ovarian morphological changes and gonadotropin surge mode secretion will be regulated by various environmental factors including age, breeds, nutrition, breeding conditions, etc.

A Comparative Analysis of Blood and Urine Luteinizing Hormone Surge According to Different Regimens of Induced Ovulatory Agens in Superovulated Menstrual Cycles (배란유도방법에 의한 과배란주기에서 혈중및 요중 황체화호르몬 Surge에 관한 연구)

  • Park, Won-Jong;Suh, Byung-Hee;Lee, Jae-Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.15 no.2
    • /
    • pp.103-117
    • /
    • 1988
  • Ovulation induction was done with 3 different regimens as clomid combined with HMG, HMG only, and FSH combined with HMG in 28 menstrual cycles for IVF-ET and GIFT program. The appearance of endogenous LH surge, estradiol plateau, atypical LH surge, and time from initiation to peak of LH surge in serum and urine were observed and compared in 3 groups. 1. The estradiol concentration of serum LH surge day was similar in three groups but 1st group (Clomiphene Citrate+Sequential HMG) was slightly higher at $1924.0{\pm}865.1\;pg/ml$. In regards to the existence of serum estradiol plateau, 3rd group (FSH+Sequential HMG) was highest at 60%, and 1st group and 2nd group (HMG only) were similar at 33% and 44% respectively. 2. The number of ovarian of ovarian follicle which was more than 18mm in diameter was $4.1{\pm}2.0$, $4.2{\pm}2.1$ respectibely for 2nd group and 3rd group. Although the numbers were slightly higher thean 1st group for each ovarian follicle, serum estradiol value per follicle was higher for 1st group at $583.0{\pm}261.2pg/ml$. 3. When measuring the urine LH surge according to Hi-Gonavi and according to the standard set by three different types of surge, simultameous satisfaction for 1st group, 2nd group, 3rd group was two cases, five cases, four cases respectively at 40%, and the remained cases were composed of numorous type combination which satisfied the two definition, simultaneously in this study, the LH surge starting time was determined only in the cases tow combination were satisfied simultaneously at first, but there are something to study more. In one case of the 3rd group. 4. The concentration of LH surge start in urine and serum of 2nd group was highest at306. $0{\pm}287.2IU/l$ and $34.0{\pm}9.9mIU/ml$ and 1st group was low at $116.6{\pm}66.1IU/l$ and 7.4mIU/ml. The urine and serum value of LH was highest at $1644.4{\pm}988.8IU/l$, $65.9{\pm}15.0mIU/ml$ for 2nd group, 1st group was low at urine, and 3rd group was low of serum. With pregnancy established, the LH concentration of urine was relatively high but on the contrary the LH concentration of serum was low compared to urine concentration. 5. Time from LH surge start to the maximun of urine and serum value was highest at 15. $7{\pm}9.1$ hrs and $10.8{\pm}4.9$ hrs for 1st group and 3rd group. With pregnancy established, time was shortened for urine but on the contrary serum showed an increase in time. 6. The concentration of LH which increases with time on urine was highest at 2nd group ($194.6{\pm}76.8\;IU/hour$). The lowest increase for serum was at 3rd group (2.1mIU/hour). With pregnancy established, urine showed more increase than control group ($266.5{\pm}47.4\;IU/hour$) and for serum there was similar increase ($3.4{\pm}0.8\;mIU/hour$). 7. There were two examples of non-typical surge from 1st group and 3rd group each. Among these three cases showed a reestablishment of LH surge after 10-24 hours. 8. Endogenous spontaneous Lh surge occurs once for each 2nd group and 3rd group.

  • PDF