• Title/Summary/Keyword: surface water quality

Search Result 1,368, Processing Time 0.029 seconds

Selection of the Optimum Organic Matter Index for Surface Water Quality Management (지표수 수질관리를 위한 적정 유기물질지표 선정)

  • Han, Dae Ho;Choi, Ji-Yong
    • Journal of Environmental Policy
    • /
    • v.10 no.4
    • /
    • pp.61-80
    • /
    • 2011
  • Through concentrated investments in environmental regulations centered around BOD, which is a biodegradable matter index, and basic environmental infrastructures, national BOD pollution level has continuously improved. Nonetheless, limitations of BOD management system has become evident through nation-wide stagnation and/or increases of refractory organic matters, such as COD, at main drinking water sources, and the need for a new index, which can easily indicate different environmental conditions, has increased. Therefore, this study suggests a new organic management index for a proper management of surface water. $COD_{Cr}$ and TOC were examined as candidates for surface water quality management index, and it was found that TOC was more appropriate than $COD_{Cr}$ as an organic matter management index. Through this study, it was found that TOC possesses following qualities: a more representative index; international acceptability; monitoring program is easier; better availability of analysis techniques; better accuracy and precision of analysis; less time required for analysis; ease of operation; management of disinfection byproducts; connection with present policies; existence of foreign and domestic application case studies; and correlation with water ecosystem.

  • PDF

A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials (단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구)

  • Jung, Young In;Choi, Sang Min
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

The State of Water Resources in the Philippines

  • Rubio, Christabel Jane P.;Jeong, Sang-Man;Lee, Joo-Heon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.82-91
    • /
    • 2008
  • This paper sought to provide information regarding the water resources in the Philippines, focusing on the issues of water quality, status of water use and water scarcity, and other threats to water availability. Although the country has sufficient amount of water resources, it was found out that water availability is still threatened by some major water resources problems: increasing water demand due to drastic growth in population, water resources pollution, droughts and flooding and weak institutional framework to address these problems. Water quality problems include increasing groundwater and surface water pollution. Moreover, drought and flooding have also increased damages in recent years due to deteriorating watersheds and high economic and population growth. In relation to these, the Government enacted national laws to define and deal with water control and quality management. The objective of this research was to present and evaluate current conditions and issues on Philippine water resources.

  • PDF

Techniques of Water Quality Improvement by Using Ozone Generation System (오존발생시스템을 이용한 하천수질 개선기법)

  • Kim, Min-Young;Ryu, Jae-Wook;Lee, Seung-Yun;Jee, Hong-Kee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2122-2126
    • /
    • 2008
  • With the degradation of water quality and, at the same time increased water usage, the sources of high quality, for examples, river/stream, municipal reservoir, wells, artisan and surface water, are diminishing. Therefore, the importance of water quality has been emphasized over the years through publications and various literature sources. Even though considerable research has resulted in significant strides for providing interpretive information and mitigation strategies for improvement of waters, the quality of which is still questionable. This study aims to propose a completely independent self-contained system for purifying waters, solar-powered ozone generator. It is a semi-permanent and cost effective environmental solution. Functions of ozone treatment are: 1) to maintain oxidative flexibility, 2) remove harmful chemicals, wastes, and other substances, and 3) prevent epizootic microbial outbreaks. Recent advances in technology have allowed the development of the practical, self-contained and independent solar powered device. Solar electrical producing panels that charge batteries are the key to using these systems anywhere electrical power is not available. This paper invites the readers to examine the problem and consider the viable, proven solution the solar powered ozone purifying system. This paper also introduces basic concept and background of solar powered ozone generators and examine its feasibility for improving water quality in rivers and streams.

  • PDF

Waste Water Treatment Using Constructed Wetland and Pond System (인공습지와 연못시스템을 이용한 오수처리)

  • Kim, Min-Hee;Yoon, Chun-Gyeong;Ham, Jong-Hwa
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.470-474
    • /
    • 2001
  • A pilot study was performed at the experimental field of Konkuk University in Seoul, to examine the waste water treatment using constructed wetland and pond system. The effluent of the wetland system in winter often exceeded effluent water quality standards for sewage treatment plant, therefore, pond system could be applied to additional system. As a result, removal rate of $BOD_{5}$, SS was 84.4%, 81.5% and effluent concentration was 4.6mg/L and 5.0mg/L respectively, when surface water of pond system was discharged in March. So we concluded that pond system stored wetland effluent in winter and discharged surface water of pond system in March, so met water quality standard.

  • PDF

Design, manufacture and field test of a surface water storage tank providing irrigation water to upland crops

  • Shin, Hyung Jin;Kim, Young-Joon;Lee, Jae Young;Kim, Hwang-Hee;Jo, Sung Mun;Cha, Sang Sun;Hwang, Seon-Ah;Lee, Seung-Kee;Park, Chan Gi
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.1057-1069
    • /
    • 2020
  • For most upland crops in Korea, underground water is used to ensure an adequate water supply. Thus, surface water storage tanks are needed to supply surface water from reservoirs or streams. This study discusses the design, manufacture and monitoring of a water storage tank capable of reliably supplying water to crops and preventing the inflow of floating debris. The study was conducted in an apple orchard in Yesan-gun, Chungcheongnam-do in Korea. Based on the water requirements of the crops and size of the orchard, a required flow volume of about 0.6 ㎥·h-1 was determined, along with a surface water storage tank capacity of 1.2 ㎥. Following a comparison with other materials, stainless steel (STS) was used to construct the water tank. The tank was designed to provide 14 hours of irrigation, enabling a small-capacity, cost-efficient tank design to be used. A surface water irrigation test was performed using the surface water storage tank. The average surface water irrigation flow rate was 0.00045 ㎥·m-2·h-1. The water quality test showed that the pH, suspended solids (SS), total nitrogen (TN), and total phosphorus (TP) values satisfied the reference values for agricultural water. The test results showed that the surface water storage tank evaluated in this study allows for crop irrigation when there is a lack of groundwater during droughts.

Water Resources Evaluation in the Philippines (필리핀의 수자원 평가)

  • Rubio, Christabel Jane;Lee, Joo Heon;Jeong, Sang Man
    • Journal of Wetlands Research
    • /
    • v.10 no.3
    • /
    • pp.47-56
    • /
    • 2008
  • This paper sought to provide information regarding the water resources in the Philippines, focusing on the issues of water quality, status of water use and water scarcity, and other threats to water availability. Although the country has sufficient amount of water resources, it was found out that water availability is still threatened by some major water resources problems: increasing water demand due to drastic growth in population, water resources pollution, droughts and flooding and weak institutional framework to address these problems. Water quality problems include increasing groundwater and surface water pollution. Moreover, drought and flooding have also increased damages in recent years due to deteriorating watersheds and high economic and population growth. In relation to these, the government enacted national laws to define and deal with water control and quality management. The objective of this research was to present and evaluate current conditions and issues on Philippine water resources.

  • PDF

Monitoring and Analysis of Nutrients in Sediments in the Riverbed (하천 퇴적물의 영양염류 모니터링)

  • Kim, Geonha;Jung, Woohyeok;Lee, Junbae
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.838-845
    • /
    • 2006
  • Characterization of sediment in the riverbed is of importance for effective water quality management, yet have not been monitored sufficiently. This paper reports monitoring results of nutrient concentrations of sediments. Surface waters and sediments were sampled four times during rainy season at five monitoring points. Organics of overlying water were increased after high flow condition followed by decreasing tendencies. Soluble phosphorus fraction among total phosphorus was increased after high flow condition while total phosphorus was in decreasing tendencies. Monitoring result suggested that more extended monitoring scheme for flow rate, scouring velocity, and suspended material is required for analyzing relationship between water quality and sediment.

Recent Progress in Surface Science and Its Application in Advanced Water Treatment by Membrane Processes

  • Matsuura, Takeshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.21-35
    • /
    • 1997
  • As environmental regulations become more stringent, water, used either as drinking water or as industrial process water, becomes increasingly better in its quality. As a result, an increasingly more advanced water treatment technology is required. It is believed that membrane technology will be able to satisfy such a requirement. The heart of the membrane technology is membrane. The advancement in water treatment technology using membranes, therefore, depends on the development of novel membranes which are superior in performance to the currently available membranes. In this paper, a brief review will be made how the recent progress in surface science, such as surface modification and surface characterization, has aided to improve the performance of the membranes used for water treatment. Some suggestions will also be made regarding the future direction of the research in this area.

  • PDF

Evaluation of Design Parameter on Residuals Treatment Facilities in Membrane Water Treatment Plants (막여과 정수장에서의 배출수처리시설 설계인자 평가)

  • Moon, Yong-Taik;Seo, In-Seok;Kim, Hong-Suck;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.138-146
    • /
    • 2006
  • The characteristics of backwash and concentrate discharges depend upon the quality of the water being treated and the net recovery of the membrane system. This paper is to indicate a design methods on the capacities of residuals treatment facilities in membrane processes for drinking water. We operated a demonstration membrane plant with a recovery rate of 90% for designing G-water treatment plant. We investigated on design parameter (optimum coagulant dosage and surface loading rate etc.) to design efficiently the residuals treatment facilities. The settling test was conducted with 1m columns dosing PACl to kaolin and membrane residuals under the experimental condition that discharge permit was under a 60mg/L. When the quantity of membrane residuals was $1,575m^3/day$, the estimated results for 1st thickener demonstrated the surface loading rate of 14.4m/day, detention time of 5.83hr, available depth of 3.5m.