• Title/Summary/Keyword: surface plasmon resonance (SPR) sensor

Search Result 54, Processing Time 0.033 seconds

Numerical Investigation on Surface Plasmon Resonance Sensor Design with High Sensitivity Using Single and Bimetallic Film Structures (고감도 단금속 및 쌍금속 표면 플라즈몬 공명 센서 설계를 위한 수치해석 연구)

  • Gwon, Hyuk-Rok;Lee, Seong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.795-800
    • /
    • 2009
  • Surface plasmon resonance (SPR) has been widely used for biological and chemical sensing applications. The present study investigates numerically the optical characteristics for the single Au film and bimetallic Ag/Au film SPR configurations by using the multiple beam interference matrix (MBIM) method. We use the prism coupling method, especially Kretschmann configuration for excitation of surface plasmon wave (SPW). The estimated results of reflectance, phase shift and magnetic field intensity enhancement factor are provided for finding out the optimum configuration with high sensitivity for SPR measurement. As a result, the optimum thicknesses are found to be 52 nm for a single Au film and 5 nm to 36 nm for bimetallic Ag-Au film. From the comparison of full width half maximum (FWHM) values for reflectance, phase shift, and enhancement of magnetic field intensity, it is concluded that the highest sensitivity can be obtained when using the phase shift for SPR sensor.

The Integrated Surface Plasmon Resonance Sensor using Polymer Optical Waveguide (폴리머 광도파로를 이용한 집적형 표면 플라즈몬 공명 센서)

  • Oh, Geum-Yoon;Kim, Doo-Gun;Kim, Hong-Seung;Lee, Tae-Kyeong;Choi, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.433-436
    • /
    • 2012
  • We propose a novel micro surface plasmon resonance (SPR) sensor system based on polymer materials. The proposed SPR system consists of the incident medium with polymer waveguide and the gold thin film for sensing area. Using a polymer optical waveguide instead of a prism in SPR sensing system offers miniaturization, low cost, and potable sensing capability. The whole device performance was analyzed using the finite-difference time domain method. The optimum gold thickness in the attenuated total reflection mirror of polymer waveguide is around 50 nm and the resonance angle to generate surface plasmon wave is 68 degrees.

The Construction of the SPR (Surface Plasmon Resonance) Sucrose Sensor (표면 플라즈몬 공명형 자당 센서의 제작)

  • Um, N.S.;Lee, S.M.;Hahm, S.H.;Koh, K.N.;Lee, S.H.;Kang, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.279-284
    • /
    • 1998
  • A surface plasmon resonance (SPR) sensor system for the determination of sucrose concentration was constructed with a gold thin film sensing chip. The properties of gold thin film are critical factors in exciting surface plasmon resonance phenomena. Therefore in the present paper, the fabrication conditions of gold thin film were investigated to optimize the SPR phenomena. The optimum thickness was obtained as $545{\AA}$ with $43.75^{\circ}$ resonance angle and good surface roughness limitation. about $3{\AA}$. The linear resonance angle shifts and rapid response were observed from the sucrose concentrations ranged from 0 to 40wt%.

  • PDF

Characteristics of a Bimetal-Layer Chip of a Surface Plasmon Resonance Sensor in the Intensity Interrogation for Tumor Marker Detection

  • Kim, Hyungjin;Kim, Chang-duk;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.243-246
    • /
    • 2016
  • The characteristics of a bimetallic surface plasmon resonance (SPR) chip were investigated to detect a tumor biomarker, carcinoembryonic antigen (CEA). The linewidth and the tangential slope of the reflectance curve of the bimetallic SPR chip was compared with those of the reflectance curve of a conventional gold (Au) SPR chip. The changes in reflectance in response to the variation in CEA in the critical concentration range were analyzed at an angle where the tangential slope of the reflectance curve was maximum. From linear regression analysis, the sensitivity of the bimetallic SPR chip with respect to the CEA in critical concentration was obtained.

Surface Plasmon Resonance Based on ZnO Nano-grating Structure (산화아연을 이용한 나노격자 구조의 표면 플라즈몬 공명)

  • Kim, Doo-Gun;Kim, Seon-Hoon;Ki, Hyun-Chul;Kim, Hwe-Jong;Oh, Geum-Yoon;Choi, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.922-926
    • /
    • 2010
  • We have investigated the grating coupled surface plasmon resonance (GC-SPR) sensors using ZnO nano-grating structures to enhance the sensitivity of an SPR sensor. The GC-SPR sensors were analyzed using the finite-difference time-domain method. The optimum resonance angles of 49 degrees are obtained in the 150 nm wide grating structure with a period of 300 nm for the ZnO thickness of 30 nm. Then, the ZnO nano-grating patterns were fabricated by using laser interference lithography. The measured resonance angle of nano-grating patterns was around 49 degrees. Here, an enhanced evanescent field is obtained due to the surface plasmon on the edge of the bandgap when the ZnO grating structures are used to excite the surface palsmon.

Detection of Pathogenic Salmonella Using a Surface Plasmon Resonance Biosensor (표면플라즈몬공명 바이오센서를 이용한 살모넬라 검출)

  • Cho, Han-Keun;Kim, Gi-Young;Kim, Woon-Ho;Sung, Min-Sun
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.116-123
    • /
    • 2010
  • Rapid detection of foodborne pathogens has been a major challenge for the food industry. Salmonella contamination is well known in all foods including pasteurised milk. The possibility of specific detection of Salmonella Enteritidis by surface plasmon resonance (SPR) biosensor was explored using a commercially available portable SPR sensor. Self assembly technique was adopted to immobilize anti-Salmonella antibodies on the gold sensing surface of the SPR sensor. The concentration of polyclonal antibody for use in the SPR biosensor was chosen to 1.0 mg/mL. Experiments were conducted at near real-time with results obtained for one SPR biosensor assay within 1 hour. The limit of detection for Salmonella Enteritidis was determined to be $10^6$ CFU/mL in both PBS buffer and milk samples. The assay sensitivity was not significantly affected by milk matrix. Our results showed that it would be possible for employing the SPR biosensor to detect Salmonella Enteritidis in near real-time.

Estimation of Sensitivity Enhancements of Material-Dependent Localized Surface Plasmon Resonance Sensor Using Nanowire Patterns (금속물질에 따른 나노구조를 이용한 국소 표면 플라즈몬 공명 센서 특성 분석)

  • Ahn, Heesang;Ahn, Dong-Gyu;Song, Yung Min;Kim, Kyujung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.5
    • /
    • pp.363-369
    • /
    • 2016
  • We explored localized plasmonic field enhancements using nanowire patterns to improve the sensitivity of a surface plasmon resonance (SPR) sensor. Two different materials, gold and silver, were considered for sample materials. Gold and silver nanowire patterns were fabricated by electron beam lithography for experimental measurements. The wavelength SPR sensor was also designed for these experiments. The material-dependent field enhancements on nanowire patterns were first calculated based on Maxwell's equations. Resonance wavelength shifts were indicated as changes in the refractive index from 1.33 to 1.36. The SPR sensor with silver nanowire patterns showed a much larger resonance wavelength shift than the sensor with gold nanowire patterns, in good agreement with simulation results. These results suggest that silver nanowire patterns are more efficient than gold nanowire patterns, and could be used for sensitivity enhancements in situations where biocompatibility is not a consideration.

Surface plasmon resonance sensor (표면 플라스몬 공명 센서의 제작)

  • Han, Won-Sik;Jung, Kyu-Jin;Lee, Sang-Won;Hong, Suk-Young;Lee, Young-Hoon;Hong, Tae-Kee
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.9-17
    • /
    • 2006
  • The application and analysis of the interaction of various biomaterials including the concentration of biomaterials, thickness, and the ability of the detection of the analytical kinetic data of special biomaterials have been performed by SPR(surface plasmon resonance) sensor. To fabricate the scanning SPR, we designed data acquisition board and LabVIEW program for the personal computer to control the SPR sensor and collect the data from detector.

SPR-based Antibody-Antigen Interaction for Real Time Analysis of Carbamate Pesticide Residues

  • Yang, Gil-Mo;Kang, Suk-Won
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.15-19
    • /
    • 2008
  • This research was conducted to develop a quick and sensitive method of detecting carbamate residues using the immobilization of antibody-antigen interactions with surface plasmon resonance (SPR). We have used commercialized surface plasmon resonance equipment (Biacore 3000). The antibody used for the immunoassay was specific for glutathione-s-transferase (GST) and the antigens included several carbamate pesticides (carbofuran, carbaryl, and benfuracarb). When antigens were applied to the protein GST, the detection limit was 2 ng/mL of carbamate pesticide. The fabricated protein GST maintained its activity for over 200 measurements. Thus we determined that the SPR biosensors could detect the specific reversible binding of a reactant in solution to a binding partner immobilized on the surface of the sensor and allow real-time detection and monitoring.

Graphene Coated Optical Fiber SPR Biosensor

  • Kim, Jang Ah;Hwang, Taehyun;Dugasani, Sreekantha Reddy;Kulkarni, Atul;Park, Sung Ha;Kim, Taesung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.401-401
    • /
    • 2014
  • In this study, graphene, the most attractive material today, has been applied to the wavelength-modulated surface plasmon resonance (SPR) sensor. The optical fiber sensor technology is the most fascinating topic because of its several benefits. In addition to this, the SPR phenomenon enables the detection of biomaterials to be label-free, highly sensitive, and accurate. Therefore, the optical fiber SPR sensor has powerful advantages to detect biomaterials. Meanwhile, Graphene shows superior mechanical, electrical, and optical characteristics, so that it has tremendous potential to be applied to any applications. Especially, grapheme has tighter confinement plasmon and relatively long propagation distances, so that it can enhance the light-matter interactions (F. H. L. Koppens, et al., Nano Lett., 2011). Accordingly, we coated graphene on the optical fiber probe which we fabricated to compose the wavelength-modulated SPR sensor (Figure 1.). The graphene film was synthesized via thermal chemical vapor deposition (CVD) process. Synthesized graphene was transferred on the core exposed region of fiber optic by lift-off method. Detected analytes were biotinylated double cross-over DNA structure (DXB) and Streptavidin (SA) as the ligand-receptor binding model. The preliminary results showed the SPR signal shifts for the DXB and SA binding rather than the concentration change.

  • PDF