• Title/Summary/Keyword: surface inclination

Search Result 275, Processing Time 0.023 seconds

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON LOWER SECOND PREMOLAR (IPS Empress 도재관의 파절강도 : 하악 제2소구치에서 교합면 두께와 축면 경사도에 따른 영향)

  • Kim Hee-Jin;Lee Hae-Hyoung;Nam Young-Sung;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.441-450
    • /
    • 2002
  • The purpose of this study was compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the lower second premolar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement. The cemented crowns were mounted on the testing jig with inclination of 30 degrees and the universal testing machine was used to measure the fracture strength. The results of this study were as follows : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (1284 N). Crowns of 1.5mm depth and $8^{\circ}$ inclination had the lowest strength (951 N). 2. There were no significant differences in the fracture strength by axial inclination of the same occlusal depth group. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth.

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON LOWER FIRST MOLAR (IPS Empress 도재관의 파절강도: 하악 제1대구치에서 교합면 두께와 축면경사도에 따른 영향)

  • Kim Sung-Hoon;Lee Jin-Han;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.48-60
    • /
    • 2003
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the lower First Molar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan). The cemented crowns were mounted on the testing jig with inclination of 30 degrees and the universal testing machine(Zwick Z020, Zwick, Germany)was used to measure the fracture strength. The results of this study were as follows : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (1789 N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (1091 N). 2. There were no significant differences in the fracture strength by axial inclination of the same occlusal depth group. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth. Size of fragment was affected by the amount of occlusal reduction.

Numerical analysis of Flow Characteristic Around an Automobile with Variation of Slant Angle of Rear End (후미경사각 변화에 따른 자동차주위 유동특성 해석)

  • 정영래;강동민;박원규
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.75-83
    • /
    • 2001
  • In this paper, numerical analysis is used to find the effects of inclination of rear end on flow characteristic around an automobile. The reference slant angle of rear end is 28.6$^{\circ}$, the slant angle of rear end is decreased to 24$^{\circ}$, 26.6$^{\circ}$ and also increased to 31.6$^{\circ}$, 36.4$^{\circ}$. The 3-D incompressible Navier-Stockes equations are solved by the iterative time marching scheme. The computed surface pressure coefficients were compared with experimental results and a good agreement has been achieved. The A- and C-pillar vortex and other flow phenomena around the ground vehicle are evidently shown. The variation of aerodynamic coefficients of drag, lift with respect to inclination angle of rear end are systematically studied. The flow characteristic on the automobile surface with respect to change of inclination of rear end have been also studied.

  • PDF

An experimental study on freezing phenomena of water saturated square cavity with inclined cold surface (경사냉각면에 따른 함수정방형내의 동결현상에 관한 실험적 연구)

  • Lee, C.H.;Kim, J.J.;Kim, B.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.435-445
    • /
    • 1997
  • It was studied the phenomena of transient freezing of an inclined water-saturated enclosure. One side of the test section was cooled and the other sides were insulated. The effects of the initial temperature, the inclination angle on the temperature field and the shape of the ice-water interface were observed. In the beginning of freezing, with increasing the inclination angle the freezing rate was increased and in the stable density layer centered $4^{\circ}C$, the freezing was fast as the convective fluid flow became small. When the initial temperature was above the $4^{\circ}C$, the frozen thickness in the upper part of inclined surface was thinner than that in the lower part, but with time the frozen thickness of upper part was thicker than that of lower part, below the $4^{\circ}C$, the frozen thickness in the upper part was thicker than that of lower part from the begining, and above the $8^{\circ}C$ in the beginning upper part was thinner with concave, but with time thicker the upper part, vanishing concave.

  • PDF

Flow Characteristics in the Converging Mini-Channels (좁아지는 유로에서의 유동 특성)

  • Karng, Sarng-Woo;Kim, Jin-Ho;Lee, Yoon-Pyo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1623-1628
    • /
    • 2004
  • Recently mini-channels or micro-channels are widely used for cooling the high density power electronic devices. Especially, the channels are used in small and high efficient equipments such as heat pipes and heat exchangers. Interfacial velocities between liquid and gas phases are very important in mini or micro-channels. In this paper, an experiment and a numerical analysis on the interfacial velocities were performed. In the experiment, the interfacial velocities which were measured by the high-speed CCD camera were about $26{\sim}33$ cm/s and the velocities increased as the inclination angle did. In the numerical experiment, CFD-ACE+, a commercial program, was used, the velocities had similar values with experimental results. As the inclination angle and the contact angle increased, the interfacial velocities did because of the surface tension which causes to move the interface. The effect of inclination angle was larger in the converging channels than in straight channels.

  • PDF

The Trend of wafer Grinding Technology and Improvement of Machining Accuracy (웨이퍼 연삭 가공 기술의 동향 및 가공 정밀도 향상에 관한 연구)

  • 안대균;황징연;이재석;이용한;하상백;이상직
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.20-23
    • /
    • 2002
  • In silicon wafer manufacturing process, the grinding process has been adopted to improve the quality of wafer such as flatness, roughness and so on. This paper describes the effect of grinding process on the surface quality of wafer. The experiments are carried out by high precision in fred grinder with air bearing spindle. The relationship between the inclination of chuck table and the flatness of wafer is investigated, and the effect of grinding conditions including wheel speed, table speed, and feed rate on damage depth and roughness of wafer is also investigated. The experimental results show that there is close relationship between the inclination of the chuck table and the flatness of wafer, and the grinding conditions within this paper little affect the flatness of wafer and relatively high affect the damage depth of wafer.

  • PDF

Analysis of Plantar Foot Pressure and Pathway of COP Depending on Inclination of Descending Ramp (내림 경사로의 기울기에 따른 족저압과 압력중심이동경로 분석)

  • Han, Jin-Tae;WhangBo, Gak
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.257-265
    • /
    • 2010
  • The purpose of this study was to investigate the effect of different ramp inclination on the maximum plantar foot pressure and pathway of the center of pressure. Fifteen healthy adults who had no musculoskeletal disorders were participated with this study and descended the ramp with different inclination(level, $-5^{\circ}$, $-10^{\circ}$, $-15^{\circ}$). Plantar foot pressures were recorded by the Matscan system(Tekscan, Boston, USA) during level and descending ramp with barefoot. Plantar foot surface was defined as seven regions for pressure measurement; two toe regions, three forefoot regions, one midfoot region, one heel region. Repeated ANOVA was used to compare each region data of foot according to different ramp inclination. As descending ramp inclination became increased, the pressure of hallux region was significantly increased at $-15^{\circ}$ inclination and the pressure of 2-3 metatasal head region were significantly decreased at $-5^{\circ}$, $-10^{\circ}$, $-15^{\circ}$ inclination. The pathway of COP had a tendency to be shifted inside in forefoot and prolonged to great toe as the descending ramp inclination increased. The results indicated that plantar foot pressure could be changed at hallux and forefoot regions with $-5^{\circ}$ ramp inclination and these findings demonstrated that ramp inclination could affect the structure and function of foot.

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECTS OF INCISAL REDUCTION AND AXIAL INCLINATION ON UPPER CANINE (IPS Empress 도재관의 파절강도 : 상악 견치에서 절단연 삭제량과 축면 경사도에 따른 영향)

  • Shin Dong-Kuk;Kang Han-Joong;Park Yong-Suck;Park Kwang-Soo;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.30-40
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal reduction (2.0mm, 2.5mm, 3.0mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper canine. Material and methods. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and the universal testing machine was used to measure the fracture strength. Results. 1. The fracture strength of the ceramic crown with 3.0mm depth and $12^{\circ}$ inclination was the highest (839N) Crowns of 2.0mm depth and $12^{\circ}$ inclination had the lowest strength (559N). 2. There was no significant difference in the fracture strength by axial inclination in the same incisal reduction group. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal reduction.

Fracture Resistance and Stress Distribution of All Ceramic Crowns with Two Types of Finish Line on Maxillary First Premolar (상악 제1소구치에서 전부도재관의 finish line 형태에 따른 파절강도와 응력 분포에 관한 연구)

  • Lee, Sang-Kwon;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.219-237
    • /
    • 2003
  • he purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown, and 0.5mm width chamfer finish lines on the maxillary first premolar. 30 sound maxillary first premolars were selected and then storaged in 5% NaOCl and saline. 15 teeth were performed preparation for each group(1.0mm rounded shoulder, 0.5mm chamfer). After 30 stone dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the natural teeth. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co., Germany)was used to measure the fracture strength, with stress loading on the occlusal surface between buccal and lingual cusp. And also, three-dimensional finite element model was used to measure the stress distribution with two types of the finish lines(1.0mm rounded shoulder, 0.5mm chamfer) and two loading conditions(both buccal and lingual cusp inclination, lingual cusp inclination only). The result of the this study were as follows. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(842N) showed higher value than that of the chamfer(590N) (p<0.05). In the three dimensional finite element analysis of all ceramic crown, metal die and natural teeth model did not show any differences in stress distribution between finish lines. Generally, when force was loaded on the occlusal inclination of buccal and lingual cusp, the stress was concentrated on the loading point and the central groove of occlusal surface. When force was loaded only on the occlusal inclination of lingual cusp, the stress was concentrated on the lingual finish line and loading point.

Fracture Resistance and Stress Distribution of All Ceramic Crowns with Two Types of Finish Line on Maxillary Central Incisor (IPS Empress 도재관의 파절강도: 하악 중절치에서 절단연 삭제량과 축면 경사도에 따른 영향)

  • Nam, Young-Sung;Kim, Kyea-Soon;Jung, Young-Chan;Kim, Yu-Lee;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.207-217
    • /
    • 2003
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the lower central ncisor. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results of this study were as follows : The fracture strength of the ceramic crown with 2.0mm depth and $12^{\circ}$ inclination was the highest (648 N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (482 N). There were no significant differences of the fracture strength by axial inclination in same incisal depth group. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal depth. There had correlation between fracture strength and fractured surface area.