• 제목/요약/키워드: surface fracture

검색결과 1,854건 처리시간 0.029초

Comminuted Radial Head Fracture in All-arthroscopic Repair of Elbow Fracture-dislocation: Is Partial Excision of the Radial Head an Acceptable Treatment Option?

  • Yang, Hee Seok;Kim, Jeong Woo;Lee, Sung Hyun;Yoo, Byung Min
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.234-239
    • /
    • 2018
  • Background: In elbow fracture-dislocation, partial excision of the comminuted radial head fracture that is not amenable to fixation remains controversial considering the accompanying symptoms. This study was undertaken to evaluate the results of radial head partial excision when the comminuted radial head fracture involved <50% of the articular surface in all-arthroscopic repair of elbow fracture-dislocation. Methods: Patients were divided into two groups based on the condition of the radial head fracture. In Group A, the patients had a radial head comminuted fracture involving <50% of the articular surface, and underwent arthroscopic partial excision. Group B was the non-excision group comprising patients with stable and non-displacement fractures. Follow-up consultations were conducted at 6 weeks and at 3, 6, 12, and 24 months after surgery. Results: In all, 19 patients (Group A: 11; Group B: 8) met the inclusion criteria and were enrolled in the study. At the final follow-up, all 19 patients showed complete resolution of elbow instability. No significant differences were observed in the range of motion, visual analogue scale score, and Mayo elbow performance score between groups. Radiological findings did not show any complications of the radiocapitellar joint. However, nonunion of the coracoid fracture was observed in 3 patients (Group A: 1; Group B: 2), without any accompanying instability and clinical symptoms. Conclusions: Considering that the final outcome is coronoid fracture fixation and lateral collateral ligament complex repair for restoring elbow stability, arthroscopic partial excision for radial head comminuted fractures involving <50% of articular surface is an effective and acceptable treatment for elbow fracture-dislocation.

표면 손상을 입은 적층판의 강도 예측 및 분석 (Prediction and Analysis of Fracture Strength for Surface Flawed Laminates)

  • 최덕현;황운봉
    • Composites Research
    • /
    • 제16권5호
    • /
    • pp.15-20
    • /
    • 2003
  • 본 논문에서는 표면 손상을 입은 적층판의 파괴 강도를 결함이 없는 적층판의 파괴 강도와 결함이 있는 적층판의 파괴 강도를 이용하여 예측하였다. 이를 위해 고전 적층판 이론을 적용하여 적층판의 파괴 강도식을 단순화했으며 이를 표면 손상을 입은 적층판에 적용하였다. 단순화한 적층판의 파괴 강도 이론식의 검증을 위해 Lagace와 Tsai의 논문에서 측정한 데이터를 이용하였다. 또한, 표면 손상을 입은 적층판의 파괴 강도 예측식의 검증을 위해 실험을 수행하였다. 실험을 위해 표면 결함이 없는 적층판과 표면 결함이 있는 적층판을 제작하여 실험하였으며 이 결과를 예측식과 비교하였다. 시편의 섬유 방향은 인장 방향과 같은 방향으로 제작되었으며, 예측식과 실험 결과는 잘 일치하였다. 따라서 본 논문에서 예측만 표면 결함이 있는 적층판의 파괴 강도 예측식을 이용하여 복합재료가 사용되는 구조물이 표면 손상이 되었을 때 이 구조물의 파괴 강도를 예측할 수 있을 것이다.

Cr-Mo강 용접열영향부의 파괴인성과 용접입열량에 관한 연구(I) (HAZ 고유조직을 중심으로) (Study on Fracture Toughness and Heat Input in Weld HAZ of Cr-Mo Steel (I) (welding structure))

  • 임재규;정세희
    • Journal of Welding and Joining
    • /
    • 제2권2호
    • /
    • pp.54-61
    • /
    • 1984
  • Construction of welding structure is greatly dependent upon welding heat cycle. Fracture toughness is decreased remarkablely due to coarse grained HAZ and inequal residual stress of three dimensions to originate in welding. Post weld heat treatment(PWHT) is carried out to increase the fracture toughness of HAZ and to remove the residual stress. There occur some problem such as toughness decrement and stress relief cracking(SRC) in the coarse grained HAZ subject to the effect of tempering treatment. Therefore, in this paper, the effect of heat inputs affecting cooling rate and PWHT under the no stress on fracture toughness were evaluated by crack opening displacement (COD), SEM and micro-hardness test. Experimental results are as follows; 1. Fracture toughness of weld HAZ is dependent upon weld heat cycle and it is decreased with increment of heat input, but the degree of improvement of fracture toughness after PWHT was linearly increased with heat input. 2. Hardness of the parent metal is not changed, but the softening of coarse grained HAZ is remarkable due to PWHT. 3. Fracture surface of as-weld show the perfect brittle fracture with the cleavage fracture, but after PWHT they appear the ductile fracture surface with dimple.

  • PDF

X-선 회절을 이용한 피로하중을 받는 일반구조용강의 잔류응력에 관한 연구 (A Study on Residual Stress for Fatigue Fracture Surface in General Purpose Structural Steel using X-ray Diffraction)

  • 조석수;장득열;주원식
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.248-261
    • /
    • 1999
  • The fatigue life of mechanical components and structures has been influenced by mechanical, material and environmental conditions. It is important to search out the load type and size for accurate cause of fracture at the damaged surface of material. The fractographic method by x-ray diffraction can utilize residual stress $\sigma$_r and half-value breadth B and find out the types and the mechanical conditions of fracture. This study showed the relationship between fracture mechanical parameters $\Delta$K, $K_{max}$ and X-ray residual stress $\sigma$_r for normalized SS41 steel with homogeneous crystal structure and M.E.F. dual phase steel(martensite encapsulated islands of ferrite). The fatigue crack propagation tests were carried out under stress ratios 0.1 and 0.5. The x-ray diffraction technique according to crack propatation direction was applied to fatigue fractured surface. Residual stress $\sigma$_r was independent on stress ratios by arrangement of $\Delta$K. The equation of $\sigma$_r$\Delta$K was established by the experimental data. Therefore, fracture mechanical parameters can be estimated can be estimated by the measurement of X-ray parameters.

  • PDF

족관절 내과 골절시 보조적 관절경적 정복 및 내고정술이 필요한가? (Is an Arthroscopically Assisted Reduction and Fixation Necessary in the Medial Malleolar Fracture of the Ankle?)

  • 신동민;주평
    • 대한관절경학회지
    • /
    • 제2권1호
    • /
    • pp.93-96
    • /
    • 1998
  • We treated 10 cases of the medial malleolar fracture of the ankle by open reduction and internal fixation from June 1997 to December 1997. After the rigid internal fixation, we measured the gap of the fracture site and the step off of the articular surface by special instrument under the ankle arthroscopy whether it was reduced anatomically or not. And we tried to know the necessity of the arthroscopically assisted reduction and fixation in the medial malleolar fracture of the ankle. Under the arthroscopic view, all 10 cases were anatomically reduced as less than 1 mm of gap of the fracture site and less than 1mm of step off of the articular surface after open reduction and internal fixation in the medial malleolar fractures. In conclusion, through the arthroscopic management, it has advantage in finding and treating the accompanying intraarticular lesion, but also has disadvantage in setting the arthroscope and prolonging the operation time.

  • PDF

컴프레서용 Al-Si 합금의 파괴 및 마모 특성 (Fracture and Wear Characteristics of Al-Si alloy used for Compressor)

  • 김재훈;김덕회
    • Tribology and Lubricants
    • /
    • 제15권2호
    • /
    • pp.141-149
    • /
    • 1999
  • Fracture, fatigue and wear characteristics of Al-Si alloy used for compressor are experimentally studied. Plane strain fracture toughness test is carried out using three point bending specimen. Fatigue test is performed under constant loading condition and wear test is carried out as a function of sliding velocity and applied load. To obtain the crack propagation characteristics and wear mechanism of Al-Si alloy, fracture and worn surfaces are investigated using SEM. It is verified that fracture and fatigue strength of Al-Si alloy are improved by the fine microstructure of alloy. The wear behavior and specific wear amount of Al-Si alloy are not dependent on the microstructure but on a function of the silicon content. Anodizing on the surface of Al-Si alloy, surface hardness and wear characteristics are improved.

FRACTAL SURFACE ROUGHNESS OF CONCRETE

  • 노영숙;;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.595-602
    • /
    • 2004
  • In this study, the roughness of fracture surfaces in cementitious material has been characterized by roughness number (RN). A systematic experimental investigation was carried out to examine the dependency of fracture parameters on the aggregate sizes as well as the loading rates. Three aggregate sizes (0.1875 in, 0.5 in, and 0.75 in) and two loading rates (slow and fast loading rate) were used. A total of 52 compression tests and 53 tension tests were performed. All fracture parameters exhibited an increase, to varying degrees, when aggregates were added to the mortar matrix. The fracture surfaces of the specimens were digitized and analyzed. Fracture roughness was monotonically increased as maximum aggregate sizes increase.

  • PDF

액정 디스플레이(LCD)의 패널유리 파손평가에 관한 연구 (Analysis on the Fracture of a Panel Glass in a Liquid Crystal Display Module under Mechanical Shock)

  • 박상후;이부윤;엄윤용
    • 한국정밀공학회지
    • /
    • 제17권12호
    • /
    • pp.76-81
    • /
    • 2000
  • Analysis on failure of the panel glass under mechanical shock is the main topic of this study. Since the glass for the LCD panel is thin, it needs to be designed to have enough toughness against mechanical shock. In this paper, a process of estimating fracture of the panel glass is proposed to guarantee reliability of the product. The fracture toughness of the panel glass is used as a criterion of the fracture based on an experimental approach. The stress intensity factor was calculated considering a model with the largest initial crack size on a cut surface and with the boundary force obtained from a dynamic finite element analysis. Critical surface roughness on the cut surface of a typical glass panel, to prevent fracture in case of bending mode, is obtained.

  • PDF

섬유강화 적층복합재의 열림모드 파괴특성 향상을 위해 $Ar^+$ 이온도움반응법을 적용한 프리프레그의 표면처리 연구 (A Study on the Surface Treatment of Prepreg with $Ar^+$ Ion to Increase Mode I Fracture Characteristics of Fiber-Reinforced Composites)

  • 이경엽;지창헌;양준호
    • 대한기계학회논문집A
    • /
    • 제24권11호
    • /
    • pp.2771-2776
    • /
    • 2000
  • In this work, the effect of surface treatment of prepreg on the mode I fracture behavior was studied. Unidirectional (0-deg) double cantilever beam (DCB) specimens were used for fracture tests. Two groups of DCB specimens were made: the first group was made of prepregs surface-treated by Ar(sup)+ ion beam under oxygen environment and the second group was made of regular prepregs. For both groups, fracture resistance curve (R-curve) was determined and compared to each other, Results showed that resistance behavior of the first group is better than that of the second group. That is, mode I fracture toughness, G(sub)Ic of the first group is 24% larger than that of the second group. SEM examination shows that the improvement of G(sub)Ic is due to the increase of interfacial strength between plies.

IPS Empress 도재관의 파절강도 : 상악 제1대구치에서 교합면 두께와 축면경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN: THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON UPPER FIRST MOLAR)

  • 최택림;이해형;동진근
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.171-183
    • /
    • 2001
  • The purpose of this study was compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the upper first molar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and were cemented with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results of this study were as follows: 1. The fracture strength of the ceramic crown with 2.5mm depth and $8^{\circ}$ inclination was the highest (1393N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (1015N) 2. There were no significant differences of the fracture strength according to occlusal depth and axial inclination. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth. 4. There was positive correlation between the fracture strength and the fracture surface area of crowns.

  • PDF