• Title/Summary/Keyword: surface damage

Search Result 2,330, Processing Time 0.027 seconds

An Analysis of the Outflow reduction effect of Bio-retention in Small watershed during Short-term rainfall (단기 강우 시 소규모유역에서 생태저류지의 유출 저감효과 분석)

  • Cheon, Jong-hyeon;Kim, Jae-moon;Jang, Young-su;Shin, Hyun-suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.434-442
    • /
    • 2019
  • Low Impact Development(LID) techniques has been attracting attention as a countermeasure to solve frequent flood damage in urban areas. LID is a techniques for returning to the natural hydrological cycle system by infiltrating the runoff from the impervious surface into the soil. The Bio-retention, one of the LID element technology has outflow reduction effect by reserving and infiltrating storm water runoff from watersheds. Recently, a number of studies have been carried out as interest in the reduction of storm water runoff and non-point pollutants in Bio-retention has increased. However, quantitative analysis on the outflow reduction of Bio-retention applied to small watershed is insufficient. In this study, Bio-retention model was constructed in a small watershed using K-LIDM which is capable of hydrologic analysis. When the storage capacity was increased or dividing the Bio-retention and watershed, the outflow reduction effect was 20% according to the storage capacity increase and 5~15% in the distributed Bio-retention system. The results of this analysis will be used as the basic data of future Bio-retention research related to watershed characteristics, vegetation type and soil condition.

A Study on Stability according to the Conservation Environment for Fixative of Korean Mural Painting Layers (한국 흙벽화 채색층 고착제의 보존환경에 따른 안정성 연구)

  • Jin, Byung-hyuk;Wi, Koang-chul
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.3
    • /
    • pp.150-171
    • /
    • 2013
  • The most important part of conservation treatment of murals is to preserve them against the risk of a damage by injecting fixative into them when the painting loses its cohesion or powderization of pigments occurred due to occurrence of cracks inside the painting layer. However, studies on the stability of fixative used for painting layers of murals are still insufficient. This study manufactured a mural as a specimen and colored it with four kinds of pigments including oyster shell white, cinnabar, malachite and red clay and applied four kinds of fixative, including, Paraloid $B-72^{(R)}$, Caparol-$binder^{(R)}$, glue and Hydoxypropyl $cellulose^{(R)}$. artificially generated environmental changes in temperature, humidity and ultraviolet rays which may occur after the completion of conservation treatment. Then the changes in physical properties were observed in multifaceted ways such as color stability, contact angle, brilliance, adhesive strength and surface. As a result, this study found that ultraviolet rays and hot?humid environment have a large impact on color stability causing changes in brightness and chroma of all painting layers where the fixative were applied, except for oyster shell white and are considered the main factors of decomposition by accelerating the aging process of fixatives applied. In comparison to the synthetic resins that were also tested in this study, the traditional glue showed satisfactory results in terms of color stability and influence preservation and the hydrophile property. As it showed exceptionally outstanding adhesive strength in all painting layers in the aspect of adhesive strength, it is considered to be highly stabile for the fixation treatment of painting layers of mural.

A Comparative Study on the Effects of Pinellia ternata, Zingiber officinale and Sobanhatang on Reflux Esophagitis (역류성 식도염에 대한 반하(半夏), 생강(生薑), 소반하탕(小半夏湯)의 효과 비교)

  • Lee, Seul-hee;Baik, Tai-Hyeun
    • The Journal of Korean Medicine
    • /
    • v.40 no.2
    • /
    • pp.17-34
    • /
    • 2019
  • Objectives: This study was carried out to observe and compare the effects of Pinellia ternata, Zingiber officinale and Sobanhatang on the reflux esophagitis induced by gastric fundus and pylorus ligation in mice with esomeprazole. Methods: Antioxidant effects were measured by DPPH radical scavenging activity at four different concentration of 0.125, 0.25, 0.5 and $1.0mg/102{\mu}{\ell}$. Zingiber officinale water extract(ZE), Pinellia ternata water extract(PE) and Sobanhatang water extract(SBE) and esomeprazole were treated orally for 14 days before gatric fundus and pylorus ligation. In the histochemistry, changes in suface mucous cells, muscle tissue and connective tissue in gastro esophageal junction(GEJ) and mast cell on the esophageal mucosa were observed. The change of Hemo oxygenase(HO)-1, ghrelin, gastrin and substance P in gastric body tissue were measured by immunohistochemistry. Results: DPPH radical scavenging activity exhibited concentration dependently increases in ZE, PE, SBE. ZE was significantly higher at all concentrations than PE. The gastric surface mucous cells were more in the treated group than in the reflux esophagitis elicited group(GE) in the order of PE, SBE, ZE and esomeprazole treateded group(PT, SBT, ZT, ET). Lower esophageal sphincter muscle damage and intercellular space in the GEJ were less in the treated group than GE. In the esophageal mucosa, the mast cell distribution and the migration of inflammatory cells were lower in the treateded troup than GE in order to ZT, SBT, PT and ET. The antioxidative enzyme, HO-1 was more in the order of ZT, SBT, control group, PT, ET than in GE. ZT was significantly higher than the other groups and SBT was significantly higher than ET. Ghrelin was found to be higher in ZT, ET, SBT and PT than in GE, and ZT was significantly higher than all other groups except ET. Gastrin showed the highest positivity in GE, and was lower in the order of ET, ZT, SBT, PT, and control group. Substance P was the highest in GE, and was lower in the order of ET, ZT, SBT, PT and control group, and PT were significantly lower than ET. Conclusion: ZT, PT and SBT showed superior antioxidative, anti-inflammatory and mucosal protective effects on mouse reflux esophagitis as compared with ET. In particular, ZE was more effective in antioxidant and gastric motility enhancement, while PE was more effective in mucosal protection and anti-inflammatory effects. Sobanhatang is expected to be effective treatment because it has advantages of both drugs and reduces toxicity.

Concrete-Panel Retaining Wall anti-crack sleeve inserted (균열방지 슬리브가 매설된 패널식 옹벽)

  • Jang, Sung-Ho;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.345-349
    • /
    • 2019
  • In Korea, the mountainous area occupies more than 70% of the whole country, cutting of earth slope that cuts a part of the ground surface is widely used when building infrastructures such as road, railroad, and industrial complex construction. In recent years, regulations on environmental damage have become more strict, and various methods have been developed and applied. Among them, Concrete-Panel Retaining Wall technique is actively applied. Concrete-Panel Retaining Wall is a method to resist horizontal earth pressure by forming a wall by attaching a precast retaining wall to the front of the support material and increasing the shear strength of the disk through reinforcement of the support material. Soil nailing, earth bolt, and ground anchor are used as support material. Among them, ground anchor is a more aggressive reinforcement type that introduces tensile load in advance to the steel wire, and a large concentrated load acts on the front panel. This concentrated load is a factor that creates cracks in the concrete panel and reduces the durability of the retaining wall itself. In this study, steel pipe sleeves and reinforcements were purchased at the anchorage of the panel to prevent cracks, and by applying bumpy shear keys to the end of the panel, the weakness of the individual behavior of the existing grout anchors was improved. The problem of degraded landscape by exposure to front concrete of retaining wall and protrusion of anchorage was solved by the production of natural stone patterns and the construction of sections that do not protrude the anchorage. In order to verify the effectiveness of anti-crack sleeves and reinforcements used in the null, indoor testing and three-dimensional numerical analysis have been performed, and the use of steel pipe sleeves and reinforcements has demonstrated the overall strength increase and crack suppression effect of panels.

The Study on Removing Paraloid B-72 from Painting Layer on Mural of Mireukjeon Hall at Geunsansa Temple (금산사 미륵전 벽화 채색층의 Paraloid b-72 제거방법과 안정성에 관한 연구)

  • Jin, Byung-Hyuk;Cho, Jae-Yeon;Park, Jin-Yeon;Han, Sung-Hee;Kim, Yong-Sun
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.3
    • /
    • pp.88-109
    • /
    • 2017
  • As the technique to remove Paraloid B-72, which is known as an irreversible material, the method using organic solvent and heating, though the ways vary depending on the kind of material to be removed, has been usually used, but it has yet to apply to mud mural because of the technical limit in processing and the potential risk of damage and, moreover, the removal efficiency which also remains unproven. Thus, in a bid to seek the way to safely remove Paraloid B-72 contained in mural, the test was conducted in a way of applying a compress method, which is deemed most efficient. The solvents which are proven to be Paraloid B-72 were applied to the absorbents such as active carbon fiber and methyl cellulose and then were eluted to the surface of mud mural sample which was prepared in the same size and condition for a certain time before evaluating the stability and removal efficiency. Such test was intended to identify the applicability to the mural of Mireukjeon Hall at Geunsansa Temple, which had been treated with Paraloid B-72 for preservation in the past. As a result, the way of mixing the absorbent such as active carbon fiber and Xylene alone or with other quick vaporable solvents proved to be most efficient in removing Paraloid B-72 from mud mural and particularly Acetone:Xylene(1:1wt%) was found to be the most stable among others. Such a test outcome is expected to be a useful data for removing Paraloid B-72 from the mural of Mireukjeon Hall at Geunsansa Temple as well as for restoring other mural cultural assets in the coming days.

Characteristics of the spatio-temporal distributions of water quality and phytoplankton communities in the Isa Stream systems (ISS) (이사천 수계의 수질환경과 식물플랑크톤 군집의 시·공간적 분포 특성)

  • Park, Jong Sick;Cheong, Cheong-Jo;Yoon, Yang Ho
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.3
    • /
    • pp.273-288
    • /
    • 2021
  • We analyzed the spatio-temporal distribution characteristics of water quality and phytoplankton communities in the Isa Stream systems (ISS) from Sangsa Lake to Suncheon Bay. Sangsa Lake showed relatively oligotrophic and mesotrophic conditions, but the freshwater and mixed brackish water zones showed more severe eutrophication than Sangsa Lake and Suncheon Bay due to the influence of industrial waste such as livestock waste. In terms of the phytoplankton community, the number of phytoplankton species was higher in freshwater and mixed brackish water zones than in Sangsa Lake and Suncheon Bay, but the cell density and Chlorophyll-a concentrations (Chl-a) were relatively high in Sanga Lake and Suncheon Bay. In particular, the mesotrophic species Fragilaria crotonensis and Asterionella formosa showed different dominance in the surface and bottom layers, and the influence of A. formosa was significant in the freshwater and mixed brackish water zones in spring and summer. However, Skeletonema costatum-ls, a eutrophic indicator species, dominated in mixed brackish water zones to seawater in autumn and winter. Thus, the severe eutrophication and rapid environmental changes in the ISS could seriously damage the coastal ecosystem in Suncheon Bay. These ecosystem changes are threatening in terms of conservation and management of the UNESCO Suncheon Biosphere Reserve and Yeoja Bay including Suncheon Bay, which recorded the first Ramsar wetland in Korea. Therefore, further research is needed to establish an in-depth management plan.

Protective Effect of Water Extract of Leonurus japonicus Houttuyn against HCl/EtOH-induced Gastric Mucosal Damage and Genotoxicity Evaluation using Micronucleus Test (익모초 물 추출물의 위염 예방효과 및 소핵시험을 이용한 유전독성 평가)

  • Nho, Jong Hyun;Lee, Hyun Joo;Jang, Ji Hun;Yang, Beo Dul;Woo, Kyeong Wan;Kim, A Hyeon;Seo, Jae Wan;Kim, Sun Young;Cho, Hyun Woo;Jung, Ho Kyung
    • Korean Journal of Plant Resources
    • /
    • v.32 no.4
    • /
    • pp.282-289
    • /
    • 2019
  • Gastritis is an inflammatory disease involving the stomach and is caused by several factors, including stress, non-steroidal anti-inflammatory drugs such as aspirin, liquor, and Helicobacter pylori. In Korea, Leonurus japonicus Houttuyn (LJW) has been used as traditional medicine for vaginal bleeding, hematuria, and bruise. Previous studies have reported that LJW exhibited hepatoprotective, cardioprotective, and anti-hyperlipidemic effect. However, the effect of the water extract of LJW on gastritis was not elucidated. Thus, we evaluated the anti-gastric effect and genotoxicity of LJW. LJW effectively prevented the degeneration of surface mucous cells and glandular epithelial cells and vascular congestion induced by HCl/EtOH. Micronucleus assay indicated that the rate of micronucleated polychromatic erythrocytes/polychromatic erythrocytes was not significantly different compared that of the control. Further experiments are required to determine the role of LJW in the gastric injury process such as cyclooxygenase signaling pathway and the secretion of mucus in the stomach.

Construction of Precise Mine Geospatial Information and Ore Modeling for Smart Mining (스마트마이닝을 위한 정밀 광산공간정보 구축 및 광체 모델링)

  • Park, Joon Kyu;Jung, Kap Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.725-731
    • /
    • 2020
  • In mineral resource development, resource exploration is a task to find economical minerals on the surface and underground, and the success rate is low compared to the development and production stages, and it is necessary to collect a lot of data through exploration and accurately analyze the collected information. In this study, mine spatial information was constructed using a 3D (Three-dimensional) laser scanner, and accuracy evaluation was performed to obtain a maximum deviation of 0.140 m and an average of 0.095 m in the X, Y and Z directions, and the possibility of utilizing the construction of mine geospatial information through a 3D laser scanner could be presented. In addition, the ore body modeling was performed by applying the interpolation method of the ore body section using the resource exploration results. The ore body modeling result was superimposed with the modeling result of the mine geospatial information built through the 3D laser scanner to construct the ore body modeling result based on the precise mine geospatial information. The results of ore body modeling based on mine geospatial information built through research can increase the ease of data interpretation and the accuracy of the calculated data, which will greatly increase the efficiency of work related to mineral resource development and mine damage prevention in the future.

Research on Improving Quality Management for Underground Space Integration Map - Focusing on pipe-type underground facilities - (지하공간통합지도 품질관리 개선방안 연구 - 관로형 지하시설물을 중심으로 -)

  • Bae, Sang-Keun;Kim, Sang-Min;Yoo, Eun-Jin
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.2
    • /
    • pp.221-235
    • /
    • 2020
  • The development and utilization of underground spaces are increasing as the use of land based on ground surface became limited due to rapid urbanization triggered by population growth and industrialization. Despite its merit of efficient use of limited land and space, it may contribute to occurrence of various disasters such as sinkholes and damage to underground facilities. After the sinkholes formed and occurred across the country in 2014, there has been an effort to establish Underground Space Integration Map containing 15 types of underground information. Still, there is an increasing demand to improve the quality of underground information stemmed from continuation of such events including the rupture of the hot water pipe in Goyang-si and the fire in the KT site in Ahyeon-dong, Seoul. Hereby, with the aim to improve the quality of Underground Space Integration Map, this study analyzes quality standards, regulations, and guidelines related to spatial data to improve quality inspection standards and methods included in the production rules for the Underground Space Integration Map. In particular, it suggests improvement plan for data quality management for pipe-type underground facilities, known as lifelines, which are essential part of daily life of the citizens, and the largest cause for accidents according to 15 types of underground information managed through the Underground Space Integration Map.

Permanent Formwork of PLA Filament utilizing 3D Printing Technology (3D 프린팅 기술을 활용한 PLA 필라멘트 비탈형 거푸집 연구)

  • Jeong, Junhyeong;Hyun, Jihun;Jeong, Heesang;Go, Huijae;Lee, Juhee;Ahn, Joseph
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.1
    • /
    • pp.81-89
    • /
    • 2021
  • In recent years, the design of buildings is changing from formal to creative and freeform. Accordingly, the scale of construction technology is changing to architectural design and construction of irregular buildings. Using the FDM method, which is one of the 3D printing technologies, it is possible to manufacture various forms of irregular formwork inexpensively and quickly coMPared to the existing formwork, and it seems to be able to solve the manpower problem. Using a 3D printer, the PLA filament formwork is produced in the form of a cylinder and a rectangular cuboid, and the usability of the PLA filament formwork is confirmed by examining the compression strength test and the degree of deformation and reusability over 28 days of age. Different sizes of additional specimens are also conducted according to the size. As a result of the experiment, it was confirmed that the filament formwork itself has about 3~4MPa strength. As a result of reviewing data through existing linear studies and experiments, it is appropriate to use more than 60% infill, and it is advantageous in terms of strength. As a result of cutting and dismantling the filament formwork, the surface is very clean and there is no damage, so it can be reused.