• Title/Summary/Keyword: surface contamination

Search Result 931, Processing Time 0.036 seconds

Evaluation of The Wear Characteristics on The White Metal Bearing in a Low Speed Two-Stroke Marine Diesel Engine (저속 2행정 박용 기관에서의 LO 입자 오염도에 따른 베어링 마모 특성 평가)

  • Ahn, Y.H.;Kim, D.Y.;Kim, Y.C.;Park, D.J.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.21-22
    • /
    • 2005
  • A study on the wear characteristics of the white metal(Sn-base alloy) bearing as a function of particle contamination level was conducted in order to establish control criteria of the lubricant in the 2-stroke marine diesel engine. Particle contamination level of the lubricants ranged from NAS 10 to 12 for the experiments. Bar-on-plate type wear test was performed using reciprocating wear tester. Based on this study it was found that there was no noticeable difference in weight loss of the white metal for NAS10 and NAS11(particle contamination level). Surface roughness of the white metal bearing after the wear test of 8hrs for the highly contaminated lubricant(NAS12 level) was up to $6{\mu}m$ in Rmax whilst that of the less contaminated lubricants(NAS10 & 11) was less than $1.5{\mu}m$ in Rmax.

  • PDF

Effect of Particle Contamination on Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RF Signal (CD-ROM 드라이브의 대물렌즈 입자오염이 Laser Diode의 Power와 Photo Diode의 RF Signal에 미치는 영향)

  • Pae, Yang-Il;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1429-1434
    • /
    • 2003
  • A number of dust particles are intruded into ODD(Optical disk drive) due to the flow caused by disk rotation and are adhered to a lens or disk surface. The space between the disk and the lens is being reduced. Someone indicates the problems of this drive that are relatively small data storing capacity and slow access time. In recent, the problems of this optical disk drive mentioned above are being solved by adding the speed of the disk's revolution, making the actuator high-speed or light, and making the beam spot size smaller than making the space narrow between disk and lens. These particle contamination affects seriously RF Signal, readout signal in an ODD. Especially, the affected parts by a particle contamination in an ODD's readout signal are objective lens and media.

  • PDF

The Effects of Slider Design on Thermal Asperity Rejection Capability

  • Choa, Sung-Hoon;Vinod Sharma;Kim, Seong-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.281-290
    • /
    • 2001
  • Particle contamination has been an ongoing problem affecting the reliability of the magnetic hard disk drives. Especially the recent use of MR head requires much tighter control of particle contamination due to thermal asperity (TA) phenomenon. In this study, the effects of slider air bearing surface design of TA reduction capability were investigated by manufacturing two types of sliders. Numerical methods were used to simulate the motion of particles in the head/media interface. Experiments were conducted to verify the results predicted by the numerical simulation. Drives were built and exposed to particle contamination using a particle injection chamber, which turned out to be a very simple and reliable particle generation method over conventional aerosol technique. Then the number of TA generated in the drives was recorded and compared. Also the contacts between slider and particles were investigated by acoustic emission study. It was found that a new ABS design, which has aerodynamic U-shaped rail and central flow passage, was beneficial in reducing the particle contamination on the slider.

  • PDF

Effect of Cleaning Pad on Particle Contamination in Removable Media Disk Drive (이동식 디스크 드라이브의 입자 오염에 대한 클리닝 패드의 효과)

  • 유신성;이정규;김대은
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.183-188
    • /
    • 2003
  • Particulate contamination is known to be a significant cause of failures of removable storage media. In this work, the effect of particles on the surface damage of removable hard disk media was investigated. The particles of different materials and size were introduced to the Head Disk Interface (HDI) using a particle injection system. It was round that the particles of particulate size and property serious damaged the media. This study showed that cleaning pad is effective for reducing particle contamination, except fer the particles of specific size and property. As a means to remove the particles of specific sire. the concept of using a stepped taper at the leading edge of the slider is proposed.

A study on the decrease of particle contamination in removable media disk drive (이동식 디스크 드라이브의 입자 오염 저감 방안)

  • 유신성;이정규;김대은
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.946-949
    • /
    • 2002
  • Particulate contamination is known to be a significant cause of failures of removable storage media. In this work, The effect of particles on the surface damage of removable hard disk media was investigated. The particles of different materials and size were introduced to the head-disk interface using a particle injection system. It was found that the particles of particulate size and property serious damaged the media. This study showed that cleaning pad is effective for reducing particle contamination, except for the particles of specific size and property. As a means to removed the particles of specific size, the concept of using a stepped taper at the leading edge of the slider is proposed.

  • PDF

Microbial change of pork carcass during processing in small size slaughterhouse (소규모 돼지도축공정에서 도체오염 미생물의 변화)

  • 홍종해;이경환;이성모
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.31-37
    • /
    • 2002
  • Major hazards existed in slaughterhouse are pathogenic microorganisms originated from intestinal microflora of slaughtered animals. This study was intended for the identification of microbial contamination sources during pork slaughtering in small plants. Total aerobic bacteria, Coliform group, Salmonella spp, Listeria monocytogenes, and Campylobacter jejuni/coli were isolated from the surface sample of pork carcasses. Contamination level among different sampling points of ham, belly and neck did not showed statistical differences. Therefore, the mixed sampling from belly and neck of carcass could be effective for microbiological monitoring. Isolation rates of pathogenic microorganisms showed Salmonella spp 20.9%, Listeria monocytogenes 10.5%, and Campylobacter jejuni/coli 8.1% from 296 sampling points. High prevalence rate of Salmonella spp indicated that the contamination of intestinal microflora occurred due to unsanitary processing control, which required HACCP system in small plants. It was recommended that the prerequisite program should be a key factor for a successful HACCP system implementation especially in small size slaughterhouse.

Study of point defects caused by a thin contamination layer in a-Si TFT-LCD

  • Oh, Jae-Young;Lee, Jae-Kyun;Yang, Moung-Su;Kang, In-Byeong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.845-848
    • /
    • 2007
  • Analysis of point defects invisible by a microscope has been studied on the a-Si thin film transistor panel. The point defects which were named Invisible Point Defect (IPD) is characterized by no particles or distortion of patterns on a pixel structure and randomly distributed on panels. To investigate the IPD, measurements were carried out: gray level driving, transistor transfer characteristic, focused ion beam (FIB), and secondary ion mass spectrometry (SIMS). The results showed that a contamination layer had a bad influence on an active surface. The contamination layer consisted of oxygen and iron from a water supply line during cleaning process. After the process tuning, IPD has been stabilized.

  • PDF

Effect of PVA Brush Contamination on Post-CMP Cleaning Performance (Post-CMP Cleaning에서 PVA 브러시 오염이 세정 효율에 미치는 영향)

  • Cho, Han-Chul;Yuh, Min-Jong;Kim, Suk-Joo;Jeong, Hae-Do
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.114-118
    • /
    • 2009
  • PVA (polyvinyl alcohol) brush cleaning method is a typical cleaning method for semiconductor cleaning process especially post-CMP cleaning. PVA brush contacts with the wafer surface and abrasive particle, generating the contact rotational torque of the brush, which is the removal mechanism. The brush rotational torque can overcome theoretically the adhesion force generated between the abrasive particle and wafer by zeta potential. However, after CMP (chemical mechanical polishing) process, many particles remained on the wafer because the brush was contaminated in previous post-CMP cleaning step. The abrasive particle on the brush redeposits to the wafer. The level of the brush contamination increased according to the cleaning run time. After cleaning the brush, the level of wafer contamination dramatically decreased. Therefore, the brush cleanliness effect on the cleaning performance and it is important for the brush to be maintained clearly.

Measurement of Radioactive Surface Contamination of the Restroom in the Hospital (병원 내 화장실의 방사성 표면오염도 측정)

  • Han, Sang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.71-76
    • /
    • 2020
  • This study measured radioactive surface contamination in general public restrooms in hospitals and in dedicated toilets for nuclear medicine. The measurement method was measured using Berthold (LB 124, Germany) at the entrance to the restroom, inside the restroom, around the restroom, in the urinal, and around the urinal. As a result of the use of the restroom, there was no dedicated place waiting for patients who received radioisotopes in one of the three hospitals. As a result of measuring the restroom for exclusive use of radioisotopes, all measurement sites in the radioiodine therapy room were the highest, and the results of measuring the public restrooms showed background level contamination at all hospitals except hospital B. However, it was measured as 8.073 Bq/㎠ and 6.426 Bq/㎠ in the urinals in the public restroom on the first floor of the B hospital. Therefore, it is recommended to explain the dangers of radiation exposure to patients and provide a place for patients to wait. In addition, a plan should be sought to prevent patients from receiving radioisotopes from using unnecessary movements and general public restrooms.

Application of Soil's Self-Decontamination Ability to Contaminated Ground (흙의 자체정화능력을 이용한 오염된 토양정화)

  • Jeong, Jin-Seob;Jhung, Jhung-Kwon;Kim, Tae-Hyung;Fang, Hsai-Yang
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.632-638
    • /
    • 2006
  • There are numerous approaches available to cleanup a contaminated surface and subsurface ground currently in use, however, these methods all classify the decontamination after the contamination has penetrated into the soil masses and is costly. Unlike these approaches, in this study, utilization of soil's self-decontamination ability by rearranging and preplanning of the topographical features and surface and subsurface drainage systems for the potential contamination sites before or during contamination process has been considered as an another cleanup method. Step by step explanations on why and how to develop the self-decontamination procedure is proposed in detail. Two examples are presented including contaminated saltwater intrusion along a coastal region and control or prevention of radioactive toxic radon gas ($^{222}Rn$) in residential areas. The effectiveness of the proposed systems to these two examples using the soil's self-decontamination ability is well illustrated.