• Title/Summary/Keyword: surface contamination

Search Result 929, Processing Time 0.028 seconds

Development of Automatic Smear Equipment for Measuring Surface Radioactivity Contamination (표면방사선 오염도 측정용 자동 스미어장치의 개발)

  • Tack, Han-Ho;Kang, Shin-Chool
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.4
    • /
    • pp.37-44
    • /
    • 2011
  • This paper was development of surface contamination automatic smear sampling for measuring radioactive contamination in radiation controlled area of nuclear facility. In indirect method a smear paper are used manually. Activity on the smear paper is affected by varying the pressures applied, by the smearing time, by the difference of ares sampled during smearing. By means of these there are erroneous. In the future the apparatus will be developed as a portable apparatus measuring smear activity automatically by adding radiation detection instrument.

A Study on TRIZ Applied Design for Contamination Preventation System of Solar Battery with Wind Amplifier (바람 증폭 장치를 가진 태양전지 오염방지시스템의 TRIZ(6SC) 응용 설계)

  • Huh, Yong Jeong;Hong, Sung Do;Kim, Jae Min
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.2
    • /
    • pp.7-11
    • /
    • 2013
  • This paper presents a study on the design for contamination preventation system of solar battery. The system of contamination preventation has an wind amplifier. Wind amplifier is conceptually designed by using TRIZ. The surface of solar battery is covered with dust during accumulate the energy. The dust cause reduce power of photovoltaic module and efficiency drop of photovoltaic system. Reflect and absorb of incident ray are caused by the dust on surface of solar battery. The solution of this problem has been derived using 6SC(6 steps creativity)TRIZ. The wind amplifier which has structure such as funnel shape. The incident wind in the wide hole is amplified by the gate become narrow. The system of contamination preventation with wind amplifier which mounted on the side of the solar battery surface reduces the reflect and absorb and improve the efficiency of photovoltaic system.

A Study on Effect of Atmospheric Gas on the Surface Cleanliness in the Batch Annealing Furnace (BAF풀림시 분위기가스가 표면 청정도에 미치는 영향에 관한 연구)

  • Yoon, Soon Hyun;Kim, Moon Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.2
    • /
    • pp.159-167
    • /
    • 1996
  • The effect of atmospheric gas on the surface cleanliness in the batch annealing furnace(BAF) is presented. It is very important to improve the surface cleanliness to investigate the surface defects such as carbon contamination, smudge and yellow color phenomenon on the surface of steel sheet. In order to study the occurrence of surface defects of steel sheet, the annealing operations were carried out in the H2 BAF with 75% hydrogen and conventional BAF with 4% hydrogen. The hydrogen is important factor that affect the energy saving in the entire annealing cycle and the surface cleanliness. In the conventional BAF, it shows that to protect the yellow color phenomenon the proper finish temperature is $80^{\circ}C$ and in the smudge sample the oxidized thickness has the depth of $120{\AA}$.

  • PDF

Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions (의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구)

  • Shin-Woo Lee;Da-eun Kim;Chae-won Mun;Gap-Jung Kim;Sang-Ha Kim;Hye-mi Park;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.171-177
    • /
    • 2024
  • In this study, two general X-ray device, CT, and MRI inspection devices were selected from general hospitals in the Daejeon area and an experiment was conducted to predict the level of infection by measuring the surface contamination of the inspection devices at different times and to use it as basic data for infection prevention. As a result, the surface contamination level by time zone for general X-ray devices and MRI examination devices was in the order of 13H > 8H > 16H, and for CT examination devices, it was 13H > 16H > 8H, which appeared to be influenced by the number of tests. In addition, the surface contamination results for each part of the test device showed that the highest ATP contamination value was found on the stand bucky handle for the general X-ray device, the headrest for the CT examination device, and the operation switch for the MRI examination device, which was closely related to the number of contacts. As a result of comparing before and after disinfection, all devices showed a significant decrease after disinfection. Based on the results of the experiment, it is believed that it can be used as basic data to identify the level of contamination in radiology laboratories and prevent infectious diseases.

Effect of Blood Contamination on Vickers Microhardness and Surface Morphology of Mineral Trioxide Aggregate

  • Jaehyun Seung;Seong-Jin Shin;Byounghwa Kim;Ji-Myung Bae;Jiyoung Ra
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.2
    • /
    • pp.165-175
    • /
    • 2024
  • This study aimed to investigate the effects of blood contamination on the Vickers hardness and the surface morphology of premixed MTA and compare them with the effects on conventional MTA. The Vickers microhardness of Endocem MTA Premixed Regular (EP) and ProRoot MTA (PM) was assessed after immersion in fetal bovine serum (FBS) and saline. Stem cells from human exfoliated deciduous teeth (SHED) were seeded on MTA after immersion in FBS, saline, and deionized water (DW). Cell adhesion patterns and surface morphology were visualized via scanning electron microscopy (SEM). The surface microhardness of EP and PM in FBS was lower than in saline. However, short-term exposure of PM to FBS did not reduce the microhardness compared to saline. Angular crystals formed in water, while rounded crystals with more air voids appeared in FBS. Favorable SHED attachment occurred in all groups. Overall, the surface hardness of EP and PM decreased after FBS exposure, although PM was less influenced. We suggest minimizing the amount of bleeding when using MTA clinically; nevertheless, PM remains an option with more expected blood contamination than EP. In summary, exposure to FBS decreased mechanical performance but allowed cell adhesion for both MTAs, with PM being more resistant to these changes.

A Comparison between the Contamination Level of Uniforms and the Nasal Staphylococcus aureus Colonization before and after the Clinical Practice of Nursing Students (간호대학생의 실습 전후 실습복 오염도 및 비강내 황색포도알균 집락정도 비교)

  • Park, Jin Hee;Shin, Gisoo;Kim, Jiyoung
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.2
    • /
    • pp.90-97
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the contamination level of uniforms with nasal colonization of Staphylococcus aureus before and after the clinical practice of nursing students. Methods: This study was a survey research, conducting microbial culture by smearing the front surface and the pockets of uniforms, and the nasal cavity both before and after clinical practice on 70 nursing students. For the analysis, descriptive statistics, chi-square test, paired t-test were used for statistical analysis using SPSS 19.0. Results: The contamination level of uniforms increased more significantly after clinical practice on the front surface (p=.008) and pockets (p=.031) than before clinical practice, and Staphylococcus aureus, and Enterobacter aerogenes were detected. Conclusion: Through the results above, it is believed that it is reasonable to do the laundering of clinical uniforms of nursing students once a week. Because it is possible to disseminate disease germs with the contamination of clinical practice uniforms in a hospital environment, it is necessary to offer education for the laundering of uniforms with appropriate management.

Diagnosis Technique of Surface Contamination Degree for EPDM Insulator according to Variation of Environment Condition (환경조건의 변화에 따른 EPDM 애자의 표면 오손정도의 진단기술)

  • Park, Jae-Jun;Choi, In-Hyuk;Kim, Jeong-Boo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1132-1141
    • /
    • 2004
  • The waveforms of the leakage currents for the surface discharge according to the degree of salt contamination and the variation of environmental condition on the EPDM polymer insulators, were shown in this paper. The variation phenomena of fundamental wave, 3rd and 5th harmonic waveforms were also shown from the beginning of the applied voltage and to the flashover voltage. To develop the technique of percentage contamination degree of EPDM polymer insulator according to the variation of environmental condition, the distortion degree of 3rd and 5th harmonic wave to the fundamental wave was utilized through the spectrum analysis for the waveforms of leakage current in the simulation of salt and fog test. The fact that distortion degree % of 3rd and 5th harmonics for fundamental wave is a necessary indicator for the assessment of contamination degree for the polymer insulators, was known.

Effects of Added Silicone Oils on the Surface Hydrophobicity of Silicone Rubber (실리콘 고무의 소수성에 미치는 첨가된 실리콘 오일의 영향)

  • Han Dong-Hee;Cho Han-Goo;Kang Dong-Pll;Min Kyung-Eun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.1
    • /
    • pp.46-51
    • /
    • 2006
  • This paper reports on the effects of silicone oils, used as processing agents, on the recovery of hydrophobicity of silicone rubber. The recovery of hydrophobicity was evaluated by the measuring the contact angle, the surface electrical resistance and SEM. Here, we formed artificial contamination on the surface of samples, which scratched by sand papers and alumina powders. There was small recovery of hydrophobicity on the surface of SIR-A that silicone oil was not added. In both oil-added samples, SIR-B and SIR-C, recovery of hydrophobicity was achieved greatly. The surface of SIR-C showed that a lot of silicone oil was observed due to migration of oil, relatively in comparison with SIR-B. The tendency of recovery of hydrophobicity expressed by contact angle was in a good agreement with electrical property as determined by surface resistivity.

Numerical Simulation on Dispersion of Fume Micro-Particles by Particle Suction Flows in Laser Surface Machining (입자 석션유동에 따른 레이저 표면가공의 마이크로 흄 오염입자 산포 특성 해석연구)

  • Kyoungjin Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.1-6
    • /
    • 2023
  • In CO2 laser surface machining of plastic films in modern display manufacturing, scattering of fume particles could be a major source of well-recognized film surface contamination. This computational fluid dynamics research investigates the suction air flow patterns over a film surface as well as the dispersion of micron-sized fume particles with low-Reynolds number particle drag model. The numerical results show the recirculatory flow patterns near laser machining point on film surface and also over the surface of vertical suction slot, which may hinder the efficient removal of fume particles from film surface. The dispersion characteristics of fume particles with various particle size have been tested systematically under different levels of suction flow intensity. It is found that suction removal efficiency of fume particles heavily depends on the particle size in highly nonlinear manners and a higher degree of suction does not always results in more efficient particle removal.

  • PDF

A study of the pollution of ground water in the basin of the river Baem Nae Chun, Sorae-Myun, Shihoong-gon, Kyonggi-Do, Korea (경기도 시흥군 소래면 뱀내하천 유역의 지하수 오염에 관한 연구)

  • 김윤종;정봉일
    • Water for future
    • /
    • v.6 no.2
    • /
    • pp.19-29
    • /
    • 1973
  • The progressive contamination of water resulted from man's activity and the use of fertilizers is not restricted only to surface water, but also the shallow groundwater is affected. This type of groundwater contamination is mainly restricted to areas composed of permeable, nonconsolidated sediments forming a shallow aquifer. The chloride and the sulfate resulted from man's activity and the use of fertilizers were measured to study the variations of the groundwater contamination. In general, (1) When water level rises, the rate of groundwater contamination becomes less and when water level declines, the rate of contamination is increased. (2) The highly contaminated season is the early-summer and the less contaminated season is the winter or after rainy season. (3) The groundwater in weathering zone without covering layer. (4) The degree of contamination of wells is increased with the increase of well depth and lowing the water table, because of increasing contaminated water from enlargement of the area of influence of the well.

  • PDF