• 제목/요약/키워드: surface contamination

검색결과 930건 처리시간 0.029초

저속 2행정 박용 기관에서의 LO 입자 오염도에 따른 베어링 마모 특성 평가 (Evaluation of The Wear Characteristics on The White Metal Bearing in a Low Speed Two-Stroke Marine Diesel Engine)

  • 안용희;김대영;김은철;박득진
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.21-22
    • /
    • 2005
  • A study on the wear characteristics of the white metal(Sn-base alloy) bearing as a function of particle contamination level was conducted in order to establish control criteria of the lubricant in the 2-stroke marine diesel engine. Particle contamination level of the lubricants ranged from NAS 10 to 12 for the experiments. Bar-on-plate type wear test was performed using reciprocating wear tester. Based on this study it was found that there was no noticeable difference in weight loss of the white metal for NAS10 and NAS11(particle contamination level). Surface roughness of the white metal bearing after the wear test of 8hrs for the highly contaminated lubricant(NAS12 level) was up to $6{\mu}m$ in Rmax whilst that of the less contaminated lubricants(NAS10 & 11) was less than $1.5{\mu}m$ in Rmax.

  • PDF

CD-ROM 드라이브의 대물렌즈 입자오염이 Laser Diode의 Power와 Photo Diode의 RF Signal에 미치는 영향 (Effect of Particle Contamination on Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RF Signal)

  • 배양일;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1429-1434
    • /
    • 2003
  • A number of dust particles are intruded into ODD(Optical disk drive) due to the flow caused by disk rotation and are adhered to a lens or disk surface. The space between the disk and the lens is being reduced. Someone indicates the problems of this drive that are relatively small data storing capacity and slow access time. In recent, the problems of this optical disk drive mentioned above are being solved by adding the speed of the disk's revolution, making the actuator high-speed or light, and making the beam spot size smaller than making the space narrow between disk and lens. These particle contamination affects seriously RF Signal, readout signal in an ODD. Especially, the affected parts by a particle contamination in an ODD's readout signal are objective lens and media.

  • PDF

The Effects of Slider Design on Thermal Asperity Rejection Capability

  • Choa, Sung-Hoon;Vinod Sharma;Kim, Seong-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제15권3호
    • /
    • pp.281-290
    • /
    • 2001
  • Particle contamination has been an ongoing problem affecting the reliability of the magnetic hard disk drives. Especially the recent use of MR head requires much tighter control of particle contamination due to thermal asperity (TA) phenomenon. In this study, the effects of slider air bearing surface design of TA reduction capability were investigated by manufacturing two types of sliders. Numerical methods were used to simulate the motion of particles in the head/media interface. Experiments were conducted to verify the results predicted by the numerical simulation. Drives were built and exposed to particle contamination using a particle injection chamber, which turned out to be a very simple and reliable particle generation method over conventional aerosol technique. Then the number of TA generated in the drives was recorded and compared. Also the contacts between slider and particles were investigated by acoustic emission study. It was found that a new ABS design, which has aerodynamic U-shaped rail and central flow passage, was beneficial in reducing the particle contamination on the slider.

  • PDF

이동식 디스크 드라이브의 입자 오염에 대한 클리닝 패드의 효과 (Effect of Cleaning Pad on Particle Contamination in Removable Media Disk Drive)

  • 유신성;이정규;김대은
    • 한국정밀공학회지
    • /
    • 제20권4호
    • /
    • pp.183-188
    • /
    • 2003
  • Particulate contamination is known to be a significant cause of failures of removable storage media. In this work, the effect of particles on the surface damage of removable hard disk media was investigated. The particles of different materials and size were introduced to the Head Disk Interface (HDI) using a particle injection system. It was round that the particles of particulate size and property serious damaged the media. This study showed that cleaning pad is effective for reducing particle contamination, except fer the particles of specific size and property. As a means to remove the particles of specific sire. the concept of using a stepped taper at the leading edge of the slider is proposed.

이동식 디스크 드라이브의 입자 오염 저감 방안 (A study on the decrease of particle contamination in removable media disk drive)

  • 유신성;이정규;김대은
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.946-949
    • /
    • 2002
  • Particulate contamination is known to be a significant cause of failures of removable storage media. In this work, The effect of particles on the surface damage of removable hard disk media was investigated. The particles of different materials and size were introduced to the head-disk interface using a particle injection system. It was found that the particles of particulate size and property serious damaged the media. This study showed that cleaning pad is effective for reducing particle contamination, except for the particles of specific size and property. As a means to removed the particles of specific size, the concept of using a stepped taper at the leading edge of the slider is proposed.

  • PDF

소규모 돼지도축공정에서 도체오염 미생물의 변화 (Microbial change of pork carcass during processing in small size slaughterhouse)

  • 홍종해;이경환;이성모
    • 한국동물위생학회지
    • /
    • 제25권1호
    • /
    • pp.31-37
    • /
    • 2002
  • Major hazards existed in slaughterhouse are pathogenic microorganisms originated from intestinal microflora of slaughtered animals. This study was intended for the identification of microbial contamination sources during pork slaughtering in small plants. Total aerobic bacteria, Coliform group, Salmonella spp, Listeria monocytogenes, and Campylobacter jejuni/coli were isolated from the surface sample of pork carcasses. Contamination level among different sampling points of ham, belly and neck did not showed statistical differences. Therefore, the mixed sampling from belly and neck of carcass could be effective for microbiological monitoring. Isolation rates of pathogenic microorganisms showed Salmonella spp 20.9%, Listeria monocytogenes 10.5%, and Campylobacter jejuni/coli 8.1% from 296 sampling points. High prevalence rate of Salmonella spp indicated that the contamination of intestinal microflora occurred due to unsanitary processing control, which required HACCP system in small plants. It was recommended that the prerequisite program should be a key factor for a successful HACCP system implementation especially in small size slaughterhouse.

Study of point defects caused by a thin contamination layer in a-Si TFT-LCD

  • Oh, Jae-Young;Lee, Jae-Kyun;Yang, Moung-Su;Kang, In-Byeong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.845-848
    • /
    • 2007
  • Analysis of point defects invisible by a microscope has been studied on the a-Si thin film transistor panel. The point defects which were named Invisible Point Defect (IPD) is characterized by no particles or distortion of patterns on a pixel structure and randomly distributed on panels. To investigate the IPD, measurements were carried out: gray level driving, transistor transfer characteristic, focused ion beam (FIB), and secondary ion mass spectrometry (SIMS). The results showed that a contamination layer had a bad influence on an active surface. The contamination layer consisted of oxygen and iron from a water supply line during cleaning process. After the process tuning, IPD has been stabilized.

  • PDF

Post-CMP Cleaning에서 PVA 브러시 오염이 세정 효율에 미치는 영향 (Effect of PVA Brush Contamination on Post-CMP Cleaning Performance)

  • 조한철;유민종;김석주;정해도
    • 한국전기전자재료학회논문지
    • /
    • 제22권2호
    • /
    • pp.114-118
    • /
    • 2009
  • PVA (polyvinyl alcohol) brush cleaning method is a typical cleaning method for semiconductor cleaning process especially post-CMP cleaning. PVA brush contacts with the wafer surface and abrasive particle, generating the contact rotational torque of the brush, which is the removal mechanism. The brush rotational torque can overcome theoretically the adhesion force generated between the abrasive particle and wafer by zeta potential. However, after CMP (chemical mechanical polishing) process, many particles remained on the wafer because the brush was contaminated in previous post-CMP cleaning step. The abrasive particle on the brush redeposits to the wafer. The level of the brush contamination increased according to the cleaning run time. After cleaning the brush, the level of wafer contamination dramatically decreased. Therefore, the brush cleanliness effect on the cleaning performance and it is important for the brush to be maintained clearly.

병원 내 화장실의 방사성 표면오염도 측정 (Measurement of Radioactive Surface Contamination of the Restroom in the Hospital)

  • 한상현
    • 한국융합학회논문지
    • /
    • 제11권8호
    • /
    • pp.71-76
    • /
    • 2020
  • 본 연구는 병원 내 일반 공용화장실과 핵의학 전용화장실내의 방사성 표면오염도를 측정하였다. 측정방법은 Berthold(LB 124, Germany)을 이용하여 화장실 입구, 대변기 안, 대변기 주위바닥, 소변기 안, 소변기 주위바닥에서 측정하였다. 화장실 사용실태 결과 3곳의 병원 중 1곳의 병원에서 방사성동위원소를 투여 받은 환자가 대기하는 전용장소가 없었다. 방사성동위원소 전용 화장실을 측정한 결과 방사성옥소 치료병실에서 모든 측정 장소가 가장 높게 측정되었고, 공용화장실을 측정한 결과는 B병원을 제외한 모든 병원의 측정 장소에서 백그라운드 수준의 오염도를 나타냈다. 하지만 B병원의 1층 공용화장실 소변기 안, 소변기 주위바닥에서 8.073 Bq/㎠, 6.426 Bq/㎠으로 측정되었다. 따라서 환자들에게 방사선피폭의 위험성을 설명하고, 환자가 대기할 수 있는 장소를 마련할 것을 권고 한다. 그리고 방사성동위원소를 투여 받은 환자는 불필요한 이동과 일반 공용화장실을 사용하지 못하도록 하는 방안이 모색되어야 할 것이다.

흙의 자체정화능력을 이용한 오염된 토양정화 (Application of Soil's Self-Decontamination Ability to Contaminated Ground)

  • 정진섭;정정권;김태형
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.632-638
    • /
    • 2006
  • 최근에 오염된 토양을 정화하기 위해서 다양한 방법들이 사용되고 있으나 이들 대부분은 이미 오염된 토양에 대한 정화기술로서 많은 비용이 수반되는 단점이 있다. 본 연구에서는 이들 방법과는 달리 잠재적인 토양오염지역에서 오염되기 전이나 혹은 진행 중일 때 지형학적인 특징, 지표 위나 아래의 배수시스템의 재배열 및 선행계획을 통해 토양자체의 정화능력을 이용하는 새로운 정화방법을 고찰하였다. 즉, 토양자체 정화과정이 왜, 어떻게 발전되는가에 대해 단계적으로 규명하였다. 해안지역에서 오염된 바닷물의 침투와 거주지역에서 유해 라돈가스($^{222}Rn$)의 조절 및 제거 등 두 가지 사례를 통해 흙의 자체정화 능력을 이용한 토양정화방법의 효율성을 평가하였다.