• Title/Summary/Keyword: surface adhesion

Search Result 2,041, Processing Time 0.026 seconds

Surface Modification of Low Density Polyethylene and Adhesion Characteristics of Low Density Polyethylene/Aluminum Laminate (저밀도 폴리에틸렌의 표면개질과 이를 이용한 저밀도 폴리에틸렌/알루미늄 라미네이트의 접착특성)

  • Jung, B.Y.;Ryu, S.H.
    • Elastomers and Composites
    • /
    • v.36 no.3
    • /
    • pp.195-200
    • /
    • 2001
  • Ultraviolet photografting of acrylic acid onto low density polyethylene was characterized using XPS and contact angle measurement. Effects of surface modification at LDPE and aluminum on LDPE/Al laminate were also investigated. Contact angle decreased significantly at initial state arid tends to level off with increasing UV irradiation time. The improvement of hydrophilicity was due to the presence of acrylic acid on LDPE surface. Graft of acrylic acid onto LDPE was also identified from O1s/C1s ratios in XPS spectrum. Adhesion strength of LDPE-g-AAc/Al laminate showed about 30 times higher than LDPE/A1 system and it could be attributed to the increase of polarity of LDPE surface. Chemical treatment of Al surface using sulfuric acid/sodium dichromate also increased the adhesion strength of LDPE/Al laminate. Adhesion strength of LDPE/Al laminate decreased significantly under acetic acid.

  • PDF

Surface Modification of Biomaterials for Hard Tissue Substitutes to Improve Biocompatibility and Osteoconductivity (생체적합성 및 골전도성 향상을 위한 경조직 대체용 생체재료의 표면개질)

  • Kim, Sung-Wook;Lee, Woo-Kul
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.725-730
    • /
    • 2005
  • In the development of biomaterials as a substitute of hard tissues, the biocompatibility and osteoconductivity of the biomaterial are considered to be one of the most significant considerations. These biological properties of a material can be greatly improved by the modification of the surface properties by the depositing calcium phosphate thin films on the material since calcium phosphate films possess similar chemical compositions to hard tissues. The success of a material as a biomaterial will be determined by the interaction of the surface of the material with the adhesion molecules which induce cellular adhesion and biological responses of the adherent cells. Depending on the adsorption mechanisms and adsorbed conformation of the adhesion molecules on the surface of the biomaterial, cellular responses, such as adhesion, proliferation and differentiation of osteoblast cells, can be promoted or restricted. It has been reported that materials of which surfaces were modified with thin films of calcium phosphate appeared to be more osteoconductive. Rapid formations of bone nodule in addition to higher differentiations of osteoblast have been observed on the calcium phosphate thin films.

Characteristics of Silver Nanow ire Solution and Film Depending on Hydroxypropyl Methylcellulose Adhesion Promoter Addition (Hydroxypropyl methylcellulose 접착력 증진제 첨가에 따른 은 나노와이어 용액 및 필름의 특성 변화)

  • Seungju Kang;Kim
    • Journal of Adhesion and Interface
    • /
    • v.24 no.2
    • /
    • pp.54-59
    • /
    • 2023
  • Silver nanowire-based transparent electrodes are very attractive as a next-generation flexible and transparent electrode that can replace ITO-based flexible electrodes because they have excellent conductivity, transmittance and mechanical flexibility. However, weak understanding of the silver nanowire solution for the fabrication of silver nanowire-based transparent electrodes often cause abnormal operation of the electrical device or peeling problem of the electrode films when applied to electronic devices. Here, we studied a Hydroxypropyl Methylcellulose (HPMC) adhesion promoter, which is one of the additives for silver nanowire solution, to improve the understanding of silver nanowire solution. In detail, it is characterized how the HPMC changes the properties of silver nanowire solution and silver nanowire film, which is fabricated with silver nanowire solution including the HPMC adhesion promoter. As the characteristics of solution, polar surface tension and dispersive surface tension were measured. As the film characteristics, surface energy, surface morphology, silver nanowire density, and sheet resistance were analyzed.

Studies on Adhesion Properties between Zinc-Coated Steel Cord and Adhesion Promoter-Containing Rubber Compound (아연 코팅된 스틸코드와 접착증진제가 적용된 고무 Compound와의 접착특성 연구)

  • Ko, Sang Min;Choi, Hee Seok;Son, Woo Jung;Kang, Sin Jung
    • Journal of Adhesion and Interface
    • /
    • v.15 no.2
    • /
    • pp.49-56
    • /
    • 2014
  • In this study, properties of adhesion between adhesion promoter-containing rubber compound and zinc coated steel cord was investigated. Cobalt salt, resorcinol formaldehyde resin (RF resin) and hexamethoxymethylmelamine (HMMM) were used to adhesion promoter. Since cobalt salts accelerate sulphidation rate of zinc at zinc coated steel cord surface, pullout force of rubber compound applying cobalt salts was increased compared to that of rubber compound without applying cobalt salts. Pullout force and rubber coverage of rubber compounds applying all adhesion promoters were superior because strong interlocking between rubber matrix increased modulus due to applying RF resin and HMMM and grown zinc sulfides at zinc coated steel cord surface.

A Molecular Simulation on the Adhesion Control of Metal Thin Film-Carbon Nanotube Interface based on Thermal Wetting (Thermal wetting 현상이 탄소나노튜브-금속박막 계면의 응착력에 미치는 영향에 관한 분자 시뮬레이션 연구)

  • Sang-Hoon Lee;Hyun-Joon Kim
    • Tribology and Lubricants
    • /
    • v.39 no.1
    • /
    • pp.8-12
    • /
    • 2023
  • This study presents a molecular simulation of adhesion control between carbon nanotube (CNT) and Ag thin film deposited on silicon substrate. Rough and flat Ag thin film models were prepared to investigate the effect of surface roughness on adhesion force. Heat treatment was applied to the models to modify the adhesion characteristics of the Ag/CNT interface based on thermal wetting. Simulation results showed that the heat treatment altered the Ag thin film morphology by thermal wetting, causing an increase in contact area of Ag/CNT interface and the adhesion force for both the flat and rough models changed. Despite the increase in contact area, the adhesion force of flat Ag/CNT interface decreased after the heat treatment because of plastic deformation of the Ag thin film. The result suggests that internal stress of the CNT induced by the substrate deformation contributes in reduction of adhesion. Contrarily, heat treatment to the rough model increases adhesion force because of the expanded contact area. The contact area is speculated to be more influential to the adhesion force rather than the internal stress of the CNT on the rough Ag thin film, because the CNT on the rough model contains internal stress regardless of the heat treatment. Therefore, as demonstrated by simulation results, the heat treatment can prevent delamination or wear of CNT coating on a rough metallic substrate by thermal wetting phenomena.

Effect of Pore Structures of a Ti-49.5Ni (at%) Alloy on Bone Cell Adhesion (Ti-49.5Ni (at%)합금의 다공성 구조가 뼈 세포 흡착에 미치는 영향)

  • Im, Yeon-Min;Choi, Jung-Il;Khang, Dong-Woo;Nam, Tae-Hyun
    • Korean Journal of Materials Research
    • /
    • v.22 no.2
    • /
    • pp.66-70
    • /
    • 2012
  • Ti-Ni alloys are widely used in numerous biomedical applications (e.g., orthodontics, cardiovascular science, orthopaedics) due to their distinctive thermomechanical and mechanical properties, such as the shape memory effect, superelasticity and low elastic modulus. In order to increase the biocompatibility of Ti-Ni alloys, many surface modification techniques, such as the sol-gel technique, plasma immersion ion implantation (PIII), laser surface melting, plasma spraying, and chemical vapor deposition, have been employed. In this study, a Ti-49.5Ni (at%) alloy was electrochemically etched in 1M $H_2SO_4$+ X (1.5, 2.0, 2.5) wt% HF electrolytes to modify the surface morphology. The morphology, element distribution, crystal structure, roughness and energy of the surface were investigated by scanning electron microscopy (SEM), energy-dispersive Xray spectrometry (EDS), X-ray diffractometry (XRD), atomic force microscopy (AFM) and contact angle analysis. Micro-sized pores were formed on the Ti-49.5Ni (at%) alloy surface by electrochemical etching with 1M $H_2SO_4$+ X (1.5, 2.0, 2.5) wt% HF. The volume fractions of the pores were increased by increasing the concentration of the HF electrolytes. Depending on the HF concentration, different pore sizes, heights, surface roughness levels, and surface energy levels were obtained. To investigate the osteoblast adhesion of the electrochemically etched Ti-49.5Ni (at%) alloy, a MTT test was performed. The degree of osteoblast adhesion was increased at a high concentration of HF-treated surface structures.

Interaction of Fibroblast Cells onto Chloric Acid-treated Poly($\alpha$-hydroxy acid) Polymer Surfaces (염소산 처리된 Poly($\alpha$-hydroxy acid)계 고분자 표면과 섬유아세포의 상호작용)

  • 이상진;강길선;이진호;이영무;이해방
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.877-885
    • /
    • 2000
  • PLA, PGA and PLGA films were treated with chloric acid mixture solution [70% perchloric acid (HClO$_4$)/potassium chlorate (KClO$_3$) aq. saturated solution, 3 : 2] to increase surface wettability and thus cell compatibility. The surface-treated PLA, PGA, and PLGA films were characterized by the measurement of water contact angle, electron spectroscopy for chemical analysis, and scanning electron microscopy. Surface wettability of chloric acid-treated PLA, PGA, and PLGA film surfaces was gradually increased with increase of treatment time. Unlike EtOH pre-treatment, chloric acid-treated polymer films maintain hydrophilic surface after drying. In cell adhesion test, fibroblasts were cultured on the chloric acid-treated film surfaces for 1 and 2 days. As the surface wettability increased, the cell adhesion on the surface were increased. In conclusion, this study demonstrated that the surface wettability of polymer plays an important role for cell adhesion and proliferation behavior.

  • PDF

Hydrophobic Self-assembled Monolayer(SAM) Coating for Enhanced Demolding Performance in Micromolding (마이크로몰딩의 이형성 향상을 위한 소수성 Self-assembled Monolayer(SAM) 코팅)

  • Park, Sang-Ha;Han, Seung-O;Park, Jong-Yeon;Mun, Seong-Uk;Park, Jeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.4
    • /
    • pp.175-183
    • /
    • 2002
  • In this paper, the surface modification effect of self-assembled monolayer(SAM) of 1-dodecanethiol [$CH_3$($CH_2$)$_{11}$SH] used as an anti-adhesive film in micromolding process was studied. Monolayers of 1-dodecanethiol[$CH_3$(CH$_2$)$_{11}$SH] were obtained by immersing a metal place in pure 1-dodecanethiol. SAM film on the nickel plate has been examined by using X-ray photoelectron spectroscopy(XPS). The focus has been placed on S-Ni bonding. From the XPS analysis, sulfur atoms were detected from the SAM film as a chemical composition of S-Ni. In order to measure an adhesion force of the SAM-coated nickel surface, atomic force microscopy(AFM) was used in force-distance mode, which whows the micro-adhesive force on solid surface. It was shown that adhesion forces measured from the SAM-coated nickel surface and the Ni surface without SAM coating were 3.52nN and 5.32nN, respectively. In order to investigate the effect of SAM coating on the surface foughness the replica in demolding process, hot embossing experiments were performed using a SAM-coated nickel master and a nickel master without SAM coating. Surface roughness of replica from the SAM-coated master showed 25nm and that of replica from master without SAM coating was 35nm. The smoother surface roughness of the replica from the SAM-coated, master is believed to result from reduction in the adhesion forces.ces.

The Effect of Fluid Shear Stress on Endothelial Cell Adhesiveness to Modified Polyurethane Surfaces

  • Gilson Khang;Lee, Sang-Jin;Lee, Young-Moo;Lee, Jin-Ho;Lee, Hai-Bang q
    • Macromolecular Research
    • /
    • v.8 no.4
    • /
    • pp.179-185
    • /
    • 2000
  • Generally vascular grafts with a relatively large inner diameter (> 5 mm) have been successfully employed for replacement in the human body. However, the use of small diameter grafts is limited, because these grafts rapidly occlude due to the thrombosis. The ideal blood-contacting surface of a prosthesis would be an endothelial cell (EC) lining, because the confluent monolayer of healthy ECs that culture natural blood vessels represents the ideal nonthrombogenic surface. For vascular graft application, the stable EC adhesion on surface under How conditions is very important. In this study, the adhesive strength of ECs attached on polymer surfaces coated with collagen type IV (Col IV), fibronectin (Fn), laminin (Ln), and treated with corona was investigated onto polyurethane (PU) films. The EC-attached PU surfaces were mounted on parallel-plate flow chambers in a How system prepared for cell adhesiveness test. Three different shear stresses (100, 150, and 200 dyne/㎠) were applied to the How chambers and each shear stress was maintained for 120 min to investigate the effect of shear stress and surface treatment condition on the EC adhesion strength. It was observed that the EC adhesion strength on the surface-modified PU films was in the order of Ln≡Fn > Col IV > corona 》 control. More than 70% of the adhered cells were remained on surface-modified PU surface after applying the shear stress,200 dyne/㎠ for 2 hrs, whereas the cells were completely detached on the control PU surface within 10 min after applying the same shear stress. It seems that the type of adsorbed proteins and hydrophilicitv onto the PU surfaces play very important roles for cell adhesion strength.

  • PDF

The study on the influence of surface cleanness and water soluble salt on corrosion protection of epoxy resin coated carbon steel

  • Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.163-169
    • /
    • 2014
  • The corrosion resistance of epoxy-coated carbon steel was evaluated. The carbon steel surface was subjected to different treatment methods such as steel grit blasting and power tool treatment as well as contamination of water soluble salt. To study the effect of the surface treatments and contamination, the topology of the treated surface was observed by confocal microscopy and a pull-off adhesion test was conducted. The corrosion resistance of the epoxy-coated carbon steel was further examined by electrochemical impedance spectroscopy (EIS) combined with immersion test of 3.5 wt% of NaCl solution. Consequently, the surface contamination by sodium chloride with $16mg/m^2$, $48mg/m^2$ and $96mg/m^2$ didn't affect the adhesion strength for current epoxy coated carbon steel and blister and rust were not observed on the surface of epoxy coating contaminated by various concentration of sodium chloride after 20 weeks of immersion in 3.5 wt% NaCl aqueous solutions. In addition, the results of EIS test showed that the epoxy-coated carbon steel treated with steel grit blasting and power tool showed similar corrosion protection performance and surface cleanness such as Sa 3 and Sa 2.5 didn't affect the corrosion protectiveness of epoxy coated carbon steel.