• Title/Summary/Keyword: surface adhesion

Search Result 2,041, Processing Time 0.029 seconds

Effect of Additional Electrical Current on Adhesion Strength between Copper and Polyimide Films (인가 전류가 구리 도금 피막과 폴리이미드 필름의 접합력에 미치는 영향)

  • Lee, Jang-Hun;Han, Yoonsung;Lee, Ho-Nyun;Hur, Jin-Young;Lee, Hong Kee
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • The effect of the additionally applied electrical current on the adhesion strength between electroless Cu and polyimide films was investigated. Peel tests were performed after applying electrical current within the range from 0.1 to 100 mA for the duration from 1 to 30 minutes. Sample with more than 1 mA of additional electrical current for 1 minute showed higher adhesion strength than that without additional electrical current. However, samples with 10 mA of additional electrical current for more than 10 miniutes showed the degradation of adhesion strength. Ra and RMS values of the peeled polyimide surface were proportional to the adhesion strength though there were no significant changes in the morphology of the peeled surfaces with varied amount and time-length of additional electrical current. Applying electrical current could increase the density of chemical bonding, which results in increase of the adhesion strength between copper and polyimide. However, in the case of applying additional electrical current for excessive amount or time, the degradation of the adhesion strength owing to the formation of copper oxide at the interface could occur.

Adhesion Force Measurements of Nano-Imprint Materials Using Atomic Force Microscope (원자력현미경을 이용한 나노임프린트 재료의 접착력 측정)

  • Yun, Hyeong Seuk;Lee, Mongryong;Song, Kigook
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.358-363
    • /
    • 2014
  • Adhesion forces between acrylate imprinting resin and a surface treated atomic force microscope (AFM) tip were investigated. Compared to the untreated silicon tip, 38% of the adhesion force is reduced for the hydrophobic tip treated with $CH_4$ plasma whereas 1.6 time increases is found for the hydrophilic tip with $O_2$ plasma treatment. Such a measurement of the adhesion force using AFM provides very quantitative results on adhesion comparing to the crosscut adhesion test which gives qualitative results. Since the adhesion area becomes larger as the imprinting pattern size gets smaller, the surface treatment issue becomes more important in the nano-imprinting process.

Interfacial Adhesion Properties of Oxygen Plasma Treated Polyketone Fiber with Natural Rubber (폴리케톤 섬유의 산소 플라즈마 처리에 따른 천연고무와의 계면접착 특성)

  • Won, Jong Sung;Choi, Hae Young;Yoo, Jae Jung;Choi, Han Na;Yong, Da Kyung;Lee, Seung Goo
    • Journal of Adhesion and Interface
    • /
    • v.13 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • Recently developed polyketone fiber has various applications in the mechanical rubber goods as reinforcement because of its good mechanical properties. However, its surface is not suitable for good adhesion with the rubber matrix. Thus, a surface modification is essential to obtain the good interfacial adhesion. Plasma treatment, in this study, has been conducted to modify the surface of the polyketone fiber. The morphological changes of the fibers by oxygen plasma treatment were observed by using SEM and AFM. The chemical composition changes of PK fiber surface treated with oxygen plasma were investigated using an XPS (X-ray photoelectron spectroscopy). Finally, the effect of these changes on the interfacial adhesion between fiber and rubber was analyzed by using a microdroplet debonding test. By the plasma treatment, oxygen moieties on the fiber surface increased with processing time and power. The surface RMS roughness increases until the proper processing condition, but a long plasma processing time resulted in a rather reduced roughness because of surface degradation. When the treatment time and power were 60 s and 80 W, respectively, the highest interfacial shear strength (IFSS) was obtained between the PK fiber and natural rubber. However, as the treatment time and power were higher than 60 s and 80 W, respectively, the IFSS decreased because of degradation of the PK fiber surface by severe plasma treatment.

Adhesion Properties of Indigenous Dadih Lactic Acid Bacteria on Human Intestinal Mucosal Surface

  • Dharmawan, Jorry;Surono, Ingrid S.;Kun, Lee Yuan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.5
    • /
    • pp.751-755
    • /
    • 2006
  • Dadih is Indonesian traditional fermented buffalo milk believed by the natives to have beneficial effects on human health. This may be due to the probiotic properties possessed by the lactic acid bacteria (LAB) involved in its fermentation process. It was discovered that ten strains of dadih lactic isolates possessed some probiotic properties in vitro. In this study, the adhesion properties of dadih LAB, in comparison with documented probiotic strains, were investigated in vitro by using mucin extracted from human faeces and Caco-2 cells as the models for human intestinal mucosal surface and intestinal cells respectively. The adhesion results showed the distinction of Lactobacillus reuteri IS-27560 in adhering to both mucus layer and Caco-2 cells. The competition assay for adhesion to the mucus layer between dadih LAB and selected pathogens indicated the competence of Lactococcus lactis IS-16183 and Lactobacillus rhamnosus IS-7257 in significantly inhibiting the adhesion of Escherichia coli O157:H7. Accordingly, these two strains may be potential candidates for use as probiotic strains. Overall, the adhesion properties of all dadih LAB strains were relatively comparable to that of Lactobacillus casei Shirota and Lactobacillus rhamnosus GG, the documented probiotic strains.

The Epoxy-metal Interphase and Its Incidence on Practical Adhesion

  • Roche, Alain Andre;Aufray, Maelenn
    • Journal of Adhesion and Interface
    • /
    • v.4 no.2
    • /
    • pp.1-9
    • /
    • 2003
  • Epoxy-amine liquid prepolymers are extensively applied onto metallic substrates and cured to obtain painted materials or bonded joint structures. Overall performances of such systems depend on the created interphase between the organic layer and the substrate. When epoxy-amine liquid mixtures are applied onto more or less hydrated metallic oxide layer, concomitant amine chemical sorption and hydroxide dissolution appear lending to the chelate formation. As soon as the chelate concentration is higher than the solubility product, these species crystallize as sharp needles. Moreover, intrinsic and thermal residual stresses are developed within painted or bonded systems. When residual stresses are higher than the organic layer/substrate adhesion, buckling, blistering, debonding may occur leading to a catastrophic drop of system performances. Practical adhesion can be evaluated with either ultimate parameters (Fmax or Dmax) or the critical strain energy release rate, using the three point flexure test (ISO 14679-1997). We observe that, for the same system, the ultimate load decreases while residual stresses increase when the liquid/solid time increases. Ultimate loads and residual stresses depend on the metallic surface treatment. For these systems, the critical strain energy release rate which takes into account the residual stress profile and the Young's modulus gradient remains quite constant whatever the metallic surface treatment was. These variations will be discussed and correlate to the formation mechanisms of the interphase.

  • PDF

Fine Structural Analysis on the Dry Adhesion System of the Jumping Spider Plexippus setipes (Araneae: Salticidae)

  • Moon, Myung-Jin;Park, Jong-Gu
    • Animal cells and systems
    • /
    • v.13 no.2
    • /
    • pp.161-167
    • /
    • 2009
  • The cuticle of spider's exoskeleton is a hydrophobic and non-adhesive material, but the jumping spiders have the distinctive attachment apparatus for adhesion on smooth dry surface without sticky fluids. We have examined the whole tarsal appendages of the jumping spider, Plexippus setipes with using scanning electron microscope to reveal the fine structural characteristics of the dry adhesion system. All eight legs have the scopulae with a pair of claws on the tip of feet. Each scopula is composed of two groups of setae that are capable of dry adhesion on smooth surface, and the hook structure of the claw is advanced to move on the rough surface. The setae toward the bottom of the tarsal segment are densely covered by numerous setules on the underside which broadened from middle to distal portion. It has been revealed by this research that the contact area of the setule is always a triangular shape, and these cuticular surfaces are connected by the elongated stalks from the underlying setae. It is likely that the nano-scale structures including a triangular depression and a longitudinal groove on each setule could functionate when the spider detach its feet from the substrate.

Electroless Silver Plating of PC/ABS and PC by Plasma Treatment and MmSH Injection Process (Plasma 처리 및 MmSH 사출방법으로 인한 PC/ABS와 PC상의 은도금 밀착성에 관한 연구)

  • Park, Ki-Y.;Lee, Hye-W.;Lee, Jong-K.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.1
    • /
    • pp.33-37
    • /
    • 2008
  • Polycarbonate has a high transmittance to light, low specific gravity, flexibility and cost-effectiveness that extends the application field of the polymer to bio-engineering, optics, electronic parts, etc. Moreover, electro plating of metallic film on PC could endow the parts the electromagnetic interference shielding capability. However, poor adhesion of copper on PC limited the wide usage in the industry. In this work, a composite(PC/ABS) and MmSH(Momentary mold Surface Heating) injection process were used to improve the plating characteristics; plating thickness, gloss and adhesion. Also plasma treatment and chemical treatment were employed for improving adhesion. Plating characteristics on PC/ABS were better than those on PC due to the anchoring effect of butadiene. MmSH injection process could ameliorate the gloss and coating adhesion. Also plating thickness and adhesion of PC and PC/ABS were increased by plasma treatment.

Adhesion and Corrosion Resistance of Electrophoretic Paint on "Electroless" Paint Coated AZ31 Mg Alloy

  • Phuong, Nguyen Van;Kim, Donghuyn;Moon, Sungmo
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.6
    • /
    • pp.405-414
    • /
    • 2018
  • The present study investigated the adhesion and corrosion resistance of subsequent electrophoretic paint (E-paint) on "electroless" paint coated AZ31 Mg alloy, which was formed by immersion of AZ31 Mg alloy in E-painting solution. It was found that with increasing immersion time of AZ31 in E-painting solution, the amount of paint deposited by electroless process increased but it decreased the electrochemical equivalent of E-painting process and the adhesion of the subsequent E-paint layer. The E-paint on electroless paint coated AZ31 contained pores with the highest pore density and the largest pore size was obtained on the samples with electroless times of 2 and 5 minutes, respectively. Results of the salt-spray test showed an accelerated growth of blisters over the entire surface of the sample immersed for less than 5 minutes whereas blisters were observed only in the vicinity of the scratch in case of samples treated for 15 and 30 minutes. The E-paint on AZ31 with shorter electroless immersion time in E-painting solution was found to have good adhesion and better corrosion resistance.

Effect of Brown Oxide Formation on the Fracture Toughness of Leadframe/EMC Interface (Brown Oxide 형성이 리드프레임/EMC 계면의 파괴인성치에 미치는 영향)

  • Lee, H.Y.;Yu, J.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.4
    • /
    • pp.531-537
    • /
    • 1999
  • A copper based leadframe was oxidized in brown-oxide forming solution, then the growth characteristics of brown oxide and the effect of brown-oxide formation on the adhesion strength of leadframe to epoxy molding compound (EMC) were studied by using sandwiched double cantilever beam (SDCB) specimens. The brown oxide is composed of fine acicular CuO, and its thickness increased up to ~150 nm within 2 minutes and saturated. Bare leadframe showed alomost no adhesion to EMC, while once the brown-oxide layer formed on the Surface of leadframe, the adhesion strength increased up to ~80 J/$\m^2$ within 2 minutes. Correlation between oxide thickness, $\delta$ and the adhesion strength in terms of interfacial fracture toughness, $G_{c}$ was linear. Considering the above results, we might conclude that the main adhesion mechanism of brown-oxide treated leadframe to EMC is mechanical interlocking, in which fine acicular CuO plays a major role.e.

  • PDF

EFFECT OF CARBON FIBER SURFACE PROPERTIES ON FIBER-MATRIX ADHESION OF THE COMPOSITES

  • Kim Mun-Han;Park Su-Jin;Lee Jae-Rak;Choe Seon-Ung
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.40-43
    • /
    • 1999
  • Electrochemical surface treatment of PAN-based carbon fibers in acidic electrolyte has been studied in increasing the surface functional groups on fiber surfaces for the improvement of fiber-matrix adhesion of the resulting composites. According to the FT-IR and XPS measurements, it reveals that the oxygen functional groups on fibers are largely influence on the composite mechanical behaviors, whereas the nitrogen functional groups are not affected in the system. In this work, a good correlation between surface functionality and mechanical properties is established.

  • PDF