• Title/Summary/Keyword: suppression rate

Search Result 498, Processing Time 0.03 seconds

A Study on the Fire Suppression Characteristics Using a Water Mist (물분무에 의한 화재제어 특성에 관한 연구)

  • 김성찬;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.261-267
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water droplet, droplet evaporation, and combustion of pool fire. The predicted temperature fields of smoke layer are compared with that of measured data. Numerical results agree with the experimental results within 5$^{\circ}C$ in the case without water mist In the case of fire suppression with water mist, numerical results dose not predict well lot temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with that of measured data. The reason of the discrepancy between predicted and measured data is due to the variation of turning rate during the injection of water mist. The effect of burning rate on the fire suppression is left as future study.

The Study on Arc Suppression of Line-to-Line Electrodes in Air and Removal of the Metaloxide (선대 선 전극방식의 대기압 아크억제 대책 및 Metaloxide 제거에 관한 연구)

  • 정종한;김문환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.264-267
    • /
    • 2004
  • Recently the pulsed power systems have been widely used in many fields such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam. In this paper, we studied various electrical characteristics for arc suppression of line-to-line electrodes in air and removal of the metaloxide using our pulsed power system. To obtain high efficiency of the pulsed power system, we repeatedly experimented and tested their characteristics. by adjusting electrode length of the load. As a result, when the value of the electrode length and pulse repetition rate were changed at the load, the value of the arc voltage changed at the electrode load. In conclusion, we controlled arc voltage of the load by ,changing electrode length and pulse repetition rate. Also. we stydied removal area of the metaloxide using area discharge according to pulse repetition rate.

Numerical analysis to determine fire suppression time for multiple water mist nozzles in a large fire test compartment

  • Ha, Gaghyeon;Shin, Weon Gyu;Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1157-1166
    • /
    • 2021
  • In this study, a numerical sensitivity analysis was performed to determine the fire suppression time for a large number of water mist nozzles in a large fire compartment. Fire simulations were performed using FDS (Fire dynamics simulator) 6.5.2 under the same condition as the test scenario 5 of the International Maritime Organization (IMO) 1165 test protocol. The sensitivities of input parameters including cell size, extinguishing coefficient (EC), droplets per second (DPS), and peak heat release rate (HRR) of fuel were investigated in terms of the normalized HRR and temperature distribution in the compartment. A new method of determining the fire suppression time using FDS simulation was developed, based on the concept of the cut-off time by cut-off value (COV) of the heat release rate per unit volume (HRRPUV) and the cooling time by the HRR cooling time criteria value (CTCV). In addition, a method was developed to determine the average EC value for the simulation input, using the cooling time and cut-off time.

Application of CFD Method to Performance Prediction of Fire-Suppression System for Electric Power Utilities (발전설비용 소화시스템의 성능 예측을 위한 CFD기법 적용 연구)

  • Chung, H.T.;Bae, K.Y.;Kim, C.H.;Jeong, I.S.;Bae, J.S.;Han, Y.S.;Kim, J.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.296-299
    • /
    • 2008
  • In the present research, the exclusive analysis system based on the CFD method were suggested to predict the fire-suppression performance of water mist fire-suppression equipments for design applications. The computing scope is ranged from starting pump to fire-suppression equipments, composed of three parts that calculation of flow rate and pressure distribution at each nozzle, examining of spray performance and predicting of fire-suppression performance in the fire space. Application were done to the fire-suppression system for electric power generation plants. The results were analyzed by comparison between numerical results and initial design conditions in terms of thermal and fluid mechanics.

  • PDF

TDMA jammer suppression on CDMA overlay

  • 김동구;박형일
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.961-971
    • /
    • 1996
  • The effect of inband TDMA narrow band jammers to DS-CDMA system performance and the suppression techniques are investigated using Monte Carlo simulations. TIA stantard North American Digital Cellular wea used as jammer. Levinson Dubin and conventional recursive least square algorithm were emphasized since these techniques can be implemented with a few DSPs for CDMA application. Two filter structures, i.e., complex suppression filter and real suppression filter in each inphase and quadrature channels, are investigated and their performances are compared. Complex suppression filter with Levinson Durbin algorithm of 20msec updata rate is the most promising with respect to implementation and performance poit of view. Implementation feasibility is discussed and the channel capacity lost by suppression is computed.

  • PDF

CO2 Suppression Characteristics of the Nitrogen-diluted Methane Counterflow Non-premixed Flame (질소로 희석된 대향류 메탄 비예혼합화염에서 CO2에 의한 소화특성)

  • Lee, Ho-Hyun;Oh, Chang Bo;Hwang, Cheol Hong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.42-48
    • /
    • 2013
  • The $CO_2$ suppression characteristics and flame structure of nitrogen-diluted methane counterflow non-premixed flame were studied experimentally and numerically. To mimic a situation where combustion product gases are entrained into a compartment fire, fuel stream was diluted with $N_2$. A gas-phase suppression agent, $CO_2$, was diluted in the air-stream to investigate the suppression characteristics by the agent. For numerical simulation, an one-dimensional OPPDIF code was used for comparison with experimental results. An optically-thin radiation model(OTM) was adopted to consider radiation effects on the suppression characteristics. It was confirmed experimentally and numerically that suppression limit decreased with increasing nitrogen mole fraction in the fuel stream. A turning point was found only when a radiation heat loss was considered and the extinguishing concentration for turning point was differently predicted compared to the experiment result. Critical extinguishing concentration when neglecting radiation heat loss was also differently predicted compared with the experimental result.

Performance of a Compton Suppression Spectrometer of the SNU-KAERI PGAA Facility

  • Sun Gwang Min;Park Chang Su;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.347-355
    • /
    • 2003
  • The \gamma-ray spectrometer of the PGAA (Prompt Gamma Activation Analysis) facility constructed at HANARO of the Korea Atomic Energy Research Institute was upgraded to the multi-mode spectrometer including the single mode, the Compton suppression mode and the pair mode. The performance of the spectrometer was tested and summarized. The background count rate and the uncertainty of the detection efficiency were reduced greatly in comparison with those before the new installation.

Residual Vibration Suppression of a Piezoelectric Beam Using a Self-sensing Technology (자기계측 기능을 이용한 압전 빔의 잔류진동 제어)

  • Nam, Yoon-Su;Jang, Hu-Yeong;Park, Jong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.3 s.192
    • /
    • pp.67-75
    • /
    • 2007
  • This paper deals with a problem of vibration suppression of a piezoelectric beam using a self-sensing algorithm. Two methods, which are PPF(positive position feedback) and SRF(strain rate feedback), are considered to suppress a residual vibration of a piezoelectric beam developed during the step positioning of a beam end point. A self-sensing algorithm treated here is basically a strain rate estimator of a beam movement and is to be used for the closed loop control. The efficacy of the proposed idea is evaluated through experiments.

Matrix Decomposition for Low Computational Complexity in Orthogonal Precoding of N-continuous Schemes for Sidelobe Suppression of OFDM Signals

  • Kawasaki, Hikaru;Matsui, Takahiro;Ohta, Masaya;Yamashita, Katsumi
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.2
    • /
    • pp.117-123
    • /
    • 2017
  • N-continuous orthogonal frequency division multiplexing (OFDM) is a precoding method for sidelobe suppression of OFDM signals and seamlessly connects OFDM symbols up to the high-order derivative for sidelobe suppression, which is suitable for suppressing out-of-band radiation. However, it severely degrades the error rate as it increases the continuous derivative order. Two schemes for orthogonal precoding of N-continuous OFDM have been proposed to achieve an ideal error rate while maintaining sidelobe suppression performance; however, the large size of the precoder matrices in both schemes causes very high computational complexity for precoding and decoding. This paper proposes matrix decomposition of precoder matrices with a large size in the orthogonal precoding schemes in order to reduce computational complexity. Numerical experiments show that the proposed method can drastically reduce computational complexity without any performance degradation.

The Efficacy of a Combination Administration of GnRH Agonist(Lupron) and Gonadotropins for Controlled Ovarian Hyperstimulation in IVF Program (체외수정시술을 위한 과배란유도시 GnRH Agonist(Lupron)와 성선자극호르몬 복합 투여의 효용성에 관한 연구)

  • Moon, Shin-Yong;Lee, Jin-Yong;Chang, Yoon-Seok
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.17 no.1
    • /
    • pp.29-44
    • /
    • 1990
  • In 105 patients with the past history of poor response to the previous controlled ovarian hyperstimulation(COH) due to poor follicular growth or premature LH surge, the effectiveness of pituitary suppression with gonadotropin-releasing hormone agonist(GnRH agonist) in IVF/GIFT program was evaluated in 112 cycles of COH using a combination regimen of Leuprolide acetate (Lupron TAP Pharmaceuticals, USA) and FSH/hMG or pure FSH from May to December, 1989 at SNUH. Starting on day 21 of the menstrual cycle(MCD #21, Day 1), Lupron (1.0mg/day, subcutaneous) was administered once a day till next MCD #3(suppression phase). After the confirmation of pituitary suppression, ovarian follicular growth was stimulated with FSH/hMG or pure FSH from MCD #3(Day + 1), and Lupron was continued with hMG or FSH until hCG administration (D 0) (stimulation phase). After suppression phase, serum E2 level decreased from 183.7${\pm}$95.1(Day 1) to 17.4${\pm}$12.3pg/ml (Day +1), and serum progesterone level from 19.17${\pm}$8.67 to 0.12${\pm}$0.05ng/ml. But there was no decresas in serum LH and FSH levels; LH from 12.74${\pm}$6.21 to 15.49${\pm}$4.93mIU/ml,FSH from 7.60${\pm}$3.84 to 8.58${\pm}$3.15 rnlU/ml. There was no occurrence of premature LH surge during COH. Eleven cycles(9.8%) were cancelled due to poor follicular growth during stimulation phase, and 3 cycles (3.0%) failed in the transvaginal oocytes fretrieval. Serum E2 level was 1366.8${\pm}$642.4 on D 0 and 1492.3${\pm}$906.9pg/ml on D+1. 7.00${\pm}$3.32 follicles(FD${\geq}$12mm) were observed on D 0, and 6.11${\pm}$4.15 oocytes were retrieved, with the oocyte retrieval rate per follicle of 95.0%. 3.59${\pm}$2.57 oocytes were fertilized and cleaved with the oocyte cleavage rate of 55.7%. In 83 IVF patients, 4.08${\pm}$2.39 embryos were transferred, and 16 pregnancies were obtained with the pregnancy rate per ET 2.39 mebryos were transferred, and 16 pregnancies were obtained with the pregnancy rate per ET of 19.3%. In 6 GIFT patients, 7.83${\pm}$3.31 oocytes were retrieved and transferred with maximum number of 6, but no pregnancy was obtained. When compared with the previous 108 cycles of COH using FSH/hMG or pure FSH regimen, the cancellation rate during COH was significantly decreased, and all the parameters of the outcome of COH including the pregnancy rate were increased. These data suggest that GnRH agonist therapy for pituitary suppression is an effective adjunct to the current gonadotropin regimens for COH in IVF/GIFT and can increase the probability of oocytes retrieval and pregnancy, especially in the previous poor responders.

  • PDF