• Title/Summary/Keyword: supplying water

Search Result 317, Processing Time 0.028 seconds

Experimental Studies on Acration in Water

  • Paik, Nam-Won;Chung, Kyou-Chull
    • Journal of Environmental Health Sciences
    • /
    • v.2 no.1
    • /
    • pp.25-28
    • /
    • 1975
  • The main purpose of the aeration units in activated sludge process is to enable micro-organisms to metabolize the constituents of the waste effectively by supplying sufficient oxygen for their respiration. Normally, aeration is achieved by bringing the mixture of waste and sludge into intimate contact with air. The main type of aeration unit is diffused air unit in which air is injected into the liquid in the form of bubbles. The object of these laboratory studies is to compare the performance of three laboratory scale aeration systems at various depths of submergence, aerating water with and without the addition of a surface active agent.

  • PDF

Effect of heat pump performance improvement by use of thermal tank with temperature seperation plate (격판분리 축열조의 히트펌프 성능개선 효과)

  • Moon, Jongpil;Lee, Sunghyoun;Kwon, Jinkyung;Kang, YounKoo;Lee, Sujang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.80.1-80.1
    • /
    • 2011
  • This study was carried out in order to estimate the effect of heat pump performance by use of thermal tank with 3 seperation plates which were able to divide thermal tank into 3 chambers that have different temperatures levels. For testing the effect of developed thermal tank which was installed for supplying the heat to the paprika greenhouse in Jinju city. The volume of thermal storage tank was designed for $110m^3$ which was able to cover 30% of heating capacity. The temperature difference was 3 degree Celcius between high temperature and low temperature when only heating circulation was made from heat pump to thermal tank. but 5.5 degree Celcius difference was made when heating circulation of heat pump to thermal thank and hot water supplying circulation of thermal tank to greenhouse was done simultaneously. As a result of this study showed that COP of heat pump was increased by 15% or more than that of using normal thermal tank because heat pump was able to take 3 ~ 5 degree Celcius lower thermal thank water constantly.

  • PDF

A STUDY ON HIGH-EFFICIENCY ATOMIZATION OF MOLTEN MATERIALS (PART 1: AN EXPERIMENTAL STUDY ON SUPPLYING MECHANISM BY AIR JETS) (Atomize 법에 의한 용융소재의 고효율 미세화에 관한 연구 (제1보:공기제트에 의한 액체의 공급기구))

  • Oh, J.G.;Lee, Ch.W.;Seok, J.K.
    • Journal of ILASS-Korea
    • /
    • v.2 no.2
    • /
    • pp.35-42
    • /
    • 1997
  • An innovating technique of atomizer has been proposed to supply and to atomise molten materials. Both of a simple geometry of nozzle and an improved nozzle have been fabricated in the present study. With these nozzles, characteristics of the suction and disintegration have been empirically investigated. The important conclusions are as follows; In the case of a simple nozzle: 1) Although the sucking up and supplying of molten materials are available, the applications of powder metallurgy are limited. 2) It is concluded that the more air flow rate, $W_A$ or the shorter the height of air nozzle from the surface of supplied water, $L_h$, the more the atomizing mass of liquids, $W_L$. In the case of an improved nozzle: 3) The stable liquids can be supplied due to cut off the passage of surrounding air entrainment by air jets. 4) The atomizing mass of liquids, $W_L$ has affected not so much on the height of nozzle from the surface of supplied water, $L_h$ as that from the orifice, hc.

  • PDF

A Numerical Study on the Control of the Gap Flow Using a Fluid Supply Device (유체 공급장치를 활용한 간극유동 제어에 관한 수치적 연구)

  • Seo, Dae-Won;Oh, Jung-Keun;Lee, Seung-Hee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.6
    • /
    • pp.578-586
    • /
    • 2009
  • Recently, horn-type rudders are generally being used at high speed container ships and are frequently suffering from the cavitation occurs on the rudder surface in the vicinity of the gap between the horn and rudder plate. In the present study, a fluid supplying device is employed as to decrease the gap cavitation of the horn-type rudder. The device is devised to inject the water against the pressure side through the nozzle installed inside of the gap to control the gap flow. Numerical calculations are performed to investigate the effectiveness of the device and the results show that the device can noticeably reduce the gap cavitation. The rates of water injection for achievement of the maximum retardations of gap flow are also sought.

Key Technologies for Floating Type Artificial Upwelling System to Strengthen Primary Production (해역 기초생산력 증대를 위한 부유식 인공용승시스템 요소기술)

  • Jung, Dong-Ho;Lee, Ho-Saeng;Kim, Hyeon-Ju;Moon, Deok-Soo;Lee, Seung-Won
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.78-83
    • /
    • 2012
  • The abundant nutrients contained in deep seawater are delivered by natural upwellings from the deep sea to the surface sea. However, the natural upwelling phenomenon is limited to specific areas of the sea; in other areas, the thermocline separates the surface sea from the lower layer. Thus, the surface layer is often deficient in nutritive salts, causing the deterioration of its primary productivity and ultimately leading to an imbalance in the marine ecosystem. Without a consistent supply of nitrogenous nutritive salts, they are absorbed by phytoplankton, resulting in a considerable problem in primary productivity. To solve this issue, a floating type of artificial upwelling system is suggested to artificially pump up, distribute, and diffuse deep seawater containing rich nutritive salts. The key technologies for developing such a floating artificial upwelling system are a floating offshore structure with a large diameter riser, self-supplying energy system, density current generating system, method for estimating the emission and absorption of CO2, and way to evaluate the primary production variation. Strengthening the primary production of the sea by supplying deep seawater to the sea surface will result in a sea environment with abundant fishery resources.

A Study on Formation and Concentration of Trihalomethanes in Water Treatment Process (정수처리공정의 THMs 생성과 농도변화에 관한 연구)

  • 조덕희;안승구
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.2
    • /
    • pp.28-34
    • /
    • 1997
  • This study was carried out to investigate the effects of prechlorination and algae growth on THMs generation. The sample water obtained from Paldang Dam which is a main source of raw water for the Seoul metropolitan area. THMs concentration in the sample water was investigated in water treatment process prechlorifiation, chemical coagulation, and sand filtration. And also, THMs concentration were analyzed in the water which cultured algae in laboratory. The results were as follows 1. The THMs concentration produced by prechlorination unit process were increased in control (not purified) but decreased in process of purification. 2. The THMs concertration can reduce by increasing the number of cleaning filters. 3. The main precursor in raw water for the THMs generation was supplied by algae growth. So as to reduce the THMs concentration in water supplying system, it is the best method to manage algae growth in water body of Paldang reservoir.

  • PDF

Automatic control problems of VVVF converter-based variable-frequency type air (VVVF기를 기초한 가변식기압급수설비의 자동제어 문제)

  • 박용규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.468-468
    • /
    • 1991
  • The variable-frequency type water supply equipment, which adopts the variable-voltage and variable-frequency converter(VVVF converter) to govern automatically the rotating speed of a pump, can save 15-20% of power, as compared with a throttle-controlled pump device or an airpressurized water supply equipment, and is finding a wide application. However, it still has some disadvantages : greater pressure fluctuations during switching over the pump and prolonged low-effeciency running of the pump in the case of small consumption of water. Therefore, it is difficult to apply the equipment to the fire water supply system where the water should not be put into use unless a fire takes place, and the water pressure in pipelines should permanently remain constant. This paper introduces the automatic regulation principle of the variable-frequency type air-pressurized water supply equipment (hereafter referred to as simply BFQS equipment) for dual purposes of daily life and fire control, which combined both technologies of speed governing by a converter and air-pressurized water supplying, then discusses some problems related to automatic control, and finally gives the experimental results of an embodiment-BPQS-100-50 water supply equipment.

  • PDF

Evaluation on the water supply stability of nakdong river basin based on future scenarios (미래 시나리오 기반 낙동강 유역의 용수공급 안정성 평가)

  • Choi, Si Jung;Kang, Seong Kyu;Lee, Dong-Ryul;Kang, Shin-Uk
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.spc
    • /
    • pp.1105-1115
    • /
    • 2018
  • In Korea, there are only a few cases that quantitative evaluate the impacts of climate change on water supply. Therefore, to ensure stable water supply in the future, a water resources plan is needed to establish by analyzing the scenarios that take into consideration the various situations in the future. In this study, we analyzed the changes of various situations for the Nakdong River basin, and constructed it for the future scenario. The stability of the water supply was analyzed through the analysis of water supply and demand prospect for each scenario path. We selected the areas expected to experience difficulty in supplying water supply and analyzed the scenarios of future water shortage by region and water sector. Also, the effect of increasing water supply capacity through optimal integrated operation of water supply facilities was analyzed and presented. Analysis of the results shows that there is a difficulty in supplying water due to future climate change experienced in the Nakdong River basin. Therefore it is necessary to prepare various countermeasures in order to mitigate or solve this problem.

Assessment of Leachate from Solid Waste Landfills in Daechong Lake Upper Drainage Basin (대청호 상류유역 매립지의 침출수 분석 및 평가)

  • Hong, Sang-Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.3
    • /
    • pp.161-170
    • /
    • 2003
  • To investigate the characteristics of 17 solid waste landfills in the upper drainage basin of Lake Daechong, the landfill sites were surveyed, the leachate of these landfills were analyzed, and the analysis results were assessed from standpoint of water contamination. Sanitary landfills which are now being operated are relatively well equipped with facilities such as leachate collection, daily soil cover and landfill gas treatment devices. But a few of open-dumping landfills were leaking leachate apparently and were supervised improperly and neglectfully by local governments. Some of sanitary landfills exceeded the COD permission criteria of leachate effluent, and some of open-dumping landfills exceeded SS, T-P, Pb, As, Fe, Mn permission criteria of leachate effluent. To improve the water quality of Lake Daechong which is utilized for supplying drinking water, agricultural water, and industrial water to the great part of Chungchong area, the adequate and prompt measures for preventing Daechong Lake water contamination from landfills leachate is necessary.

Demonstration study of desalination system with renewable energy (신재생에너지를 이용한 해수담수시스템 실증 연구)

  • Joo, Hong-Jin;Hwang, In-Seon;Joo, Moon-Chang;Kwak, Hee-Youl
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.197.1-197.1
    • /
    • 2010
  • This study was carried out to evaluate the operating performances of the evaporation desalination system with solar energy. This system was designed to use evacuated solar collector as the heat source, supplying the required heat energy and photovoltaic power as the electric source, supplying required power to pumps in the desalination system. The 5kW photovoltaic power generation system to make the electricity, the single-stage fresh water generator with plate heat exchanger, and remote control and monitoring system. Solar desalination system was designed and installed in Jeju-island, Korea in 2006, after about 4 years of operation, usability and stability of solar desalination system was guaranteed. The system comprises of the desalination unit which was designed to have daily fresh water capacity of $2m^3$, a $120m^2$ evacuated tubular solar collector to supply the heat, a $6m^3$ heat storage tank, and a 5.2kW photovoltaic power generation to supply the electricity to hydraulic pumps for the heat medium fluids. On a clear day, average daily solar irradiance in Jeju-island was measured to be $500W/m^2$ and the daily fresh water yield showed to be more than 500 liters under this condition. After around three years of a long term operation of the system from January 2007 to August 2009, average daily freshwater yield was analyzed to be around $330{\ell}$. The relationship equation between solar irradiance and freshwater yield was found to be y=1.1806x - 107.89.

  • PDF