• Title/Summary/Keyword: supply water

Search Result 3,509, Processing Time 0.026 seconds

Simulation of Water Redistribution for the Resized Beneficiary Area of a Large Scale Agricultural Reservoir (대규모 농업용저수지 수혜면적 변화에 따른 효율적 용수재분배 모의)

  • Sung, Muhong;Jeung, Minhyuk;Beom, Jina;Park, Taesun;Lee, Jaenam;Jung, Hyoungmo;Kim, Youngjoo;Yoo, Seunghwan;Yoon, Kwangsik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.3
    • /
    • pp.1-12
    • /
    • 2021
  • Optimal water management is to efficiently and equally supply an appropriate amount of water by using irrigation facilities. Therefore, it is necessary to evaluate water supply capacity through distribution simulation between the designed distribution rate and re-distributed rate according to the changed farming conditions. In this study, we recalculated the agricultural water supply amount of Geumcheon main canal, which beneficiary area was reduced due to the development of Gwangju-Jeonnam innovation city, and we constructed a canal network using the SWMM model to simulate the change in supply rate of each main canal according to the re-distributed rate. Even though the supply amount of the Geumcheon main canal was reduced from 1.20 m3/s to 0.90 m3/s, it showed a similar supply rate to the current, and the reduced quantity could be supplied to the rest of the main canal. As a result, the arrival time at the ends of all main canal, except for the Geumcheon main canal, decreased from 1 to 3 hours, and the supply rate increased from 4 to 17.0% at the main canal located at the end of the beneficiary area of Naju reservoir.

농촌지역 간이상수도 수질에 대한 수리지화학적 특성: 충남 금산군 일대

  • 이진수;고경석;김용재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.369-372
    • /
    • 2004
  • This study presents the hydrogeochmical investigation to know the effect of geology and sources for water quality in small potable water supply system at rural area. The results of water quality in Geumsan area showed the 3.2% of water samples exceeded the limit of drinking water standard by bacteria. The hydrochemical investigation results indicated the high EC, Ca and HCO$_3$ in surface water and metasedimentary rocks and this is caused by the dissolution of calc-slicate minerals of metasedimentary rocks.

  • PDF

Study on the cooling water supply method to the cooling water injection nozzle in the steam generator (증기발생기 내 냉각수 분사 노즐로의 냉각수 공급 방법에 관한 연구)

  • Oh, Jeong-hwa;Shin, Min-kyu;Cho, Young-seok;Ko, Young-sung
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.66-72
    • /
    • 2020
  • In this study, a method for increasing the initial water supply was employed to protect the water injection nozzle by the flame when supplying the water to the steam generator. During the initial steam generator test, the flow rate was controlled by using the only venturi, but cooling water was not supplied to the combustion chamber at the beginning of combustion, thereby resulting in damage to the water nozzle. To solve this problem, a venturi and an orifice were configured in parallel to increase the initial supply flow rate to form a differential pressure between the water manifold and the combustion chamber. Venturi and orifice supply sequences were established through the water flow tests, and combustion tests were conducted for final verification. Consequently, a continuous supply of the cooling water at the beginning of combustion was achieved, and the experiment was successfully performed without damaging the cooling water nozzle.

A Study on the Simple Piped Water Supply System in a Rural Area (일부 농촌지역의 간이 상수도 운영실태와 개선 방안에 관한 조사연구)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 1991
  • This study was carried out for 5 years between 1984 and 1986 and 1989 and 1990. This interviewers visited 292 households to evaluate the perception of the residents using .the. Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 42 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are surmnarized as follows: 1) Approximately 55% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 16 sites and valley water in 26 sites. 3) Considering the type of distribution of the SPWS, there are 28 natural gravity systems and 14 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 74% of the SPWS facilities were used more than ten years. In addition, 40% of residents expressed the need for repairs of old facilities. 5) 48% of the SPWS facilities are neighbored with pollution source. 6) 50% of the maintenance crews were not committed totheir job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 85% of the residents answered that SPWS was convenient and helpful. 8) About 57% of the residents complaind that the amount of daily water supply is not adequate. 9) About 74% of the residents felt that the water quality is high for dringking water and therefore, 52% of the facilities were not properly chlorinated. But in contrast, the biochemical tests indicated that only 28% of the SPWS met the dringking water quality standards. 10) Maintenance cost per a household ranges form 500 to 2, 000Won (1 $ = 700 Won) a month. Most of the cost was to cover the power electric charge. For the effective maintenance and arrangement of the facilities, gorvermental financial support for the maintenance is strongly recommended.

  • PDF

Evaluation of SRI Water Management on the Reduction of Irrigation Supply and NPS Pollution in Paddies (SRI 물관리 방법이 논의 관개용수량과 비점오염원 저감에 미치는 영향)

  • Seo, Jiyeon;Park, Baekyung;Park, Woonji;Yoon, Kwangsik;Choi, Dongho;Kim, Yongseok;Ryu, Jichul;Choi, Joongdae
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.2
    • /
    • pp.183-190
    • /
    • 2016
  • Monitored data (rainfall runoff and water quality) from 4 different paddy sites over 3 years were compared to analyze the effect of irrigation water management on irrigation supply and rainfall runoff quality in Korea. The system of rice intensification water management was adopted at one site (SRI) while the conventional water management method was used for rice culture at the other three sites (CT, SD and HD). The soil texture at SRI, CT and SD was sandy loam while that at HD was silt loam. The average reduction of irrigation supply at SRI compared with CT, SD and HD during the 3 years studied was 49%, 51% and 55%, respectively. The average event mean concentration (EMC) at SRI compared with that at CT, SD and HD was decreased by 35% (BOD), 44% (COD), 47% (SS), 19% (TN) and 38% (TP). The correlation between rainfall runoff and the measured non-point source (NPS) pollutants was very good in general. The comparison revealed that SRI water management significantly reduced both irrigation supply and EMC in rainfall runoff. Paddy NPS pollution was closely related to factors that induce runoff such as rainfall and irrigation supply. It was concluded that SRI management could be an effective and practical option to cope with both water shortage due to climate change and water quality improvement in rural watersheds. However, further studies are recommended in large irrigation districts for use in the development and implementation of NPS pollution policies since the data was collected from field sized paddies.

Agricultural Drought Assessment and Diagnosis Based on Spatiotemporal Water Supply in Irrigated Area (필지단위 관개용수 공급에 따른 농업가뭄진단 평가)

  • Shin, Ji-Hyeon;Nam, Won-Ho;Kim, Ha-Young;Mun, Young-Sik;Bang, Na-Kyoung;Lee, Jueng-Chol;Lee, Kwang-Ya
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.4
    • /
    • pp.1-12
    • /
    • 2021
  • Agricultural drought is a natural phenomenon that is not easy to observe and predict and is difficult to quantify. In South Korea, the amount of agricultural water used is large and the types of use are varied, so even if an agricultural drought occurs due to insufficient precipitation, the drought actually felt in the irrigated area is it can be temporally and spatially different. In order to interpret the general drought in the past, drought disasters were evaluated using single indicators such as drought damage area, precipitation shortage status, and drought index, and a comprehensive drought management system is needed through drought diagnosis survey. Therefore, we intend to conduct research on agricultural drought assessment and diagnosis using re-evaluation of agricultural facilities and irrigation water supply network due to changes in various conditions such as climate change, irrigation canal network, and evaluation of water supply capacity of agricultural facilities. In this study, agricultural drought diagnosis was conducted on two agricultural reservoirs located in Sangju, Gyeongsangbuk-do, with structural or non-structural evaluations to increase spatiotemporal water supply and efficiency in terms of water shortages. The results of the agricultural drought diagnosis evaluation can be used to identify irrigated areas and canal network vulnerable to drought and to prioritize drought response.

Change of Microbiological Quality according to Various Storage Conditions in the Drinking Process of Bottled Mineral Water (먹는 샘물의 개봉 후 음용과정에서의 보관 조건에 따른 미생물학적 수질 변화)

  • Bae, Kyung-Seon;Kim, Jihye;Jang, JunHyeong;Kim, Jeong Myeong;Lee, Wonseok;Chung, Hyen-Mi;Park, Sangjung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.6
    • /
    • pp.499-508
    • /
    • 2017
  • Objective: This study was conducted to investigate changes in microbiological quality according to various storage conditions in the drinking process of bottled mineral water. Methods: Heterotrophic plate counts ($21^{\circ}C$ and $36^{\circ}C$) and pathogenic indicators (total coliforms, fecal Streptococcus, Pseudomonas aeruginosa, Clostridium perfringens, Salmonella, and Shigella) were analyzed in commercial bottled mineral water stored under different conditions ($4^{\circ}C$, $20-25^{\circ}C$, $36^{\circ}C$) after injecting saliva. The heterotrophic plate counts were analyzed twice per day for the first week and once per day for the three weeks after. Pathogenic indicators were analyzed at the beginning and end (initial and final). Results: The results of the microbiological quality of the bottled mineral water in contact with saliva showed that heterotrophic plate counts ($21^{\circ}C$) had a tendency to be sustained or decrease slightly after 10 days. Heterotrophic plate counts ($36^{\circ}C$) had a high population in the initial samples and gradually decreased at $4^{\circ}C$ storage, but it remained constantly high in storage at $20-25^{\circ}C$ and $36^{\circ}C$. In the general drinking condition, the population was slightly higher than the control, but the overall trend was similar. Conclusions: As a result of the microbiological quality of mineral bottled water in contact with saliva during the process of drinking, heterotrophic plate counts ($21^{\circ}C$ and $36^{\circ}C$) showed a high population compared to the control, which was only opened and not in contact with saliva. In some samples, pathogenic indicators were also detected. Therefore, it is desirable to consume bottled mineral water as soon as possible after opening.

Analysis of Emergency Water Supply Effects of Multipurpose Dams Using Water Shortage Index (용수부족지표를 이용한 다목적댐의 비상용수 공급 효과 분석)

  • Lee, Gwang-Man;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.11
    • /
    • pp.1143-1156
    • /
    • 2012
  • One of the important purposes of most water resources systems is to prevent from drought damages. However, there are uncertainties in water supply plans from a reservoir due to factors such as limitation of available data, inaccuracy of surveyed data, unsuitability of analysis method, and climate change. In actual operating process, severe drought exceeding the water supply capability makes the normal water usage difficult. In Korea, however, alternative water source such as a development of new water project is very limited in case of water shortages due to drought. Especially, since there is no standard to evaluate the water supply effect considering severe drought damages, it is difficult to prepare the practical measures. In this study, water shortage events of existing multipurpose reservoirs are analyzed and the method of using low-storage emergency water supply is studied by using Water Shortage Index (WSI). The water shortage events are analyzed and the effect of water shortage decrease is evaluated using the existing inflow data of multi-purpose reservoirs. The results show that Imha, Daechung, Hapchon and Namkang reservoirs are highly vulnerable to the severe drought and required to develop additional emergency water source.

A Study on the design and evaluation of connection pipes for stable water supply (용수공급 안정화를 위한 연계관로 설계 및 평가)

  • Chang, Yong-Hoon;Kim, Ju-Hwan;Jung, Kwan-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.249-256
    • /
    • 2012
  • The paper describes a design methodology that can select a proper reliability factor and apply the selected reliability factor into the real water distribution system. Reliability factors which are used for the assesment of water supply networks, can be categorized by a connectivity, a reachability, an expected shortage and an availability. Among these factors, an expected shortage is the most proper reliability factor in the aspect of economic evaluation. Therefore, the expected shortage is applied to draw a water supply reliability into Changwon water supply systems. And the economic pipe diameter can be determined as 600mm for a connection pipe in the pipe network from the estimation of the expected shortage. Also, a quantitative effect of the connection pipe can be expressed in terms of the reduction, which is estimated by the expected shortage of 30,269$m^{3}$ from 68,705$m^{3}$ at initial condition to 38,436$m^{3}$ under the connected condition with the diameter 600mm pipe.

Thermal Performance of Solar Cooling & Hot-water System According to Control Condition (태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능)

  • Lee, Ho;Joo, Hong-Jin;Kim, Sang-Jin;Kwak, Hee-Yeol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF