• 제목/요약/키워드: supplementary reinforcement

검색결과 34건 처리시간 0.037초

Test of Headed Reinforcement in Pullout II: Deep Embedment

  • Choi, Dong-Uk
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.151-159
    • /
    • 2006
  • A total of 32 pullout tests were performed for the multiple headed bars relatively deeply embedded in reinforced concrete column-like members. The objective was to determine the minimum embedment depth that was necessary to safely design exterior beam-column joints using headed bars. The variables for the experiment were embedment depth of headed bar, center-to-center distance between adjacent heads, and amount of supplementary reinforcement. Regular strength concrete and grade SD420 reinforcing steel were used. The results of the test the indicated that a headed bar embedment depth of $10d_b$ was not sufficient to have relatively closely installed headed bars develop the pullout strength corresponding to the yield strength. All the experimental variables, influenced the pullout strength. The pullout strength increased with increasing embedment depth and head-to-head distance. It also increased with increasing amount of supplementary reinforcement. For a group of closely-spaced headed bars installed in a beam-column joint, it is recommended to use column ties at least 0.6% by volume, 1% or greater amount of column main bars, and an embedment depth of $13d_b$ or greater simultaneously, to guarantee the pullout strength of individual headed bars over 125% of $f_y$ and ductile load-displacement behavior.

보조 띠철근으로써 V-타이의 부착-미끄러짐 관계 실험 (Bond-Slip Tests of V-ties as a Supplementary Lateral Reinforcement)

  • 권혁진;양근혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.157-158
    • /
    • 2017
  • This tests examined bond stress-slip relationship of V-ties embedded into concrete as a supplementary lateral reinforcement proposed for ductility of concrete flexural members. The different leg shapes of V-ties were prepared as a test parameter. The V-tie with pressed end-legs exhibited 28% higher bond strength than the conventional V-ties, whereas bond stress-slip curves were insignificantly affected by the embedment length of V-ties.

  • PDF

사출성형제품 부형상의 지적 설계에 관한 연구 (A Study on the Development of Intelligent Supplementary Feature Designer(ISFD) in Injection Molding)

  • 강성남;허용정
    • 한국정밀공학회지
    • /
    • 제18권8호
    • /
    • pp.164-173
    • /
    • 2001
  • The configuration of injection molded part can be classified into primary feature and supplementary feature. Even though supplementary features such as ribs, snap fits and bosses make mold more complicated, which cause the increasement of the mold cost, supplementary features should be attached to primary features because of assembly, reinforcement, moldability and other functional purposes. But it is not easy for novice designers to design them appropriately because of the profound knowledge related to Injection molding. In this paper, the intelligent design tool called ISFD(Intelligent Supplementary Feature Designer) which supplies easy, simple, time and cost-effective design method has been studied and developed. A knowledge-based design system is a new tool which enables the concurrent design and CIM with integrated and balanced design decisions at the initial design stage of injection molding.

  • PDF

시멘트 대체재료를 사용한 노후 저수지의 사면 개량에 따른 차수 및 보강 효과 분석 (Analysis of the Waterproof and Reinforcement Effect according to Slope Improvement of Aging Reservoir using Supplementary Cementitious Material)

  • 송상훤;조대성
    • 한국건설순환자원학회논문집
    • /
    • 제10권1호
    • /
    • pp.30-39
    • /
    • 2022
  • 본 연구에서는 비탈면 보강을 위해 순환자원을 재활용하여 개발된 시멘트 대체재료를 사용하여 노후 저수지의 사면 개량 재료로 활용하기 위해 실내시험 및 수치해석, 현장에서의 시험시공을 실시하고, 결과를 분석하였다. 실내시험 결과, 점착력과 내부마찰각의 변화를 고려할 때 시멘트 대체재료의 혼합비는 9 %가 적절하며, 투수계수는 약 10,000배 감소하여 국내에서 적용되고 있는 차수재료에 근접한 수준을 나타내는 것으로 분석되었다. 또한 수치해석과 시험시공 결과, 시멘트 대체재료를 사용하여 보강한 부분에서는 침투가 발생하지 않고, 국내 기준 대비 높은 안전율을 확보할 수 있어 충분한 차수 및 보강효과를 보이는 것으로 나타났다. 따라서 노후 저수지를 보강하기 위해 사용되고 있는 기존의 시멘트를 사용한 보수 및 보강방법을 충분히 대체할 수 있을 것으로 판단된다.

기둥의 단면 확대보강을 위한 V-타이 보조 띠철근의 형상 제시 (Proposals of Reliable Shapes of Supplementary V-ties for Section Jacketing Method of Columns)

  • 권혁진;양근혁;심재일
    • 한국건축시공학회지
    • /
    • 제18권2호
    • /
    • pp.99-107
    • /
    • 2018
  • 이 연구의 목적은 기존 철근콘크리트 기둥의 내진보강을 위한 단면 확대보강공법에서 보조 띠철근으로써 배근할 수 있는 V-타이의 상세를 제시하는 것이다. 모두 24개의 직접 인발실험체에서 V-타이의 역학적 거동을 고려한 부착강도 관점에서 선택한 주요 변수는 V-타이의 형상, 묻힘길이 및 콘크리트 강도이다. 다양한 상세를 갖는 V-타이의 부착강도는 일반 V-타이의 부착강도 및 CEB-FIP 제안식과 비교하였다. 그 결과 보강단면의 두께가 기존 V-타이의 묻힘 길이[= max(75mm, $6d_b$)]보다 적은 기둥의 경우 단부 압착형의 V-타이가 보조 띠철근로 추천될 수 있었는데, 여기서 $d_b$는 V-타이로 사용된 철근의 직경이다.

CGS 공법 적용 석회암 공동지역의 교량기초보강 사례 연구 (A Study on the Reinforcement Case of Bridge Foundation in the Limestone Cavity with CGS Method)

  • 박성수;홍종욱;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제14권12호
    • /
    • pp.43-52
    • /
    • 2013
  • 석회암은 일반적으로 망상형 공동이나 석회암 동굴 같은 대규모 공동을 형성시키고, 싱크홀과 돌리네 형태로 발전하기도 한다. 이러한 공동은 도로, 댐 등을 건설할 때 지반이 상부구조물을 지탱하지 못하여 부등침하 등으로 심각한 문제를 야기할 수 있어 공동충전 등의 보강이 필요하게 된다. 본 연구에서는 CGS 공법에 의한 석회암 공동지역의 구조물 기초 지반보강을 실시하고, 이를 통해 보강효과를 공학적으로 평가하였다. 먼저, 시추조사를 통해 지반의 구성 및 공학적 특성을 파악하였다. 또한, CGS 보강을 실시한 후, 보강검증을 위해 시추조사를 실시하였고, 시추조사 시 채취된 보강재코어 중 대표적인 시료에 대해 암석시험을 실시하여 보강재에 대한 물리적 특성을 파악하였다. 그 결과 CGS 공법을 적용한 후, 시추조사 시 채취된 보강재코어 중 대표적인 시료에 대해서 압축강도시험을 실시한 결과 공동 내 재료의 충전 상태가 양호한 것으로 나타났으며, 일축압축강도도 12.2~19.2(MPa)로 충분한 것으로 검토되어 석회암 공동이 적절하게 보강된 것으로 확인하였다.

Durability performance of concrete containing Saudi natural pozzolans as supplementary cementitious material

  • Al-Amoudi, Omar S. Baghabra;Ahmad, Shamsad;Khan, Saad M.S.;Maslehuddin, Mohammed
    • Advances in concrete construction
    • /
    • 제8권2호
    • /
    • pp.119-126
    • /
    • 2019
  • This paper reports an experimental investigation conducted to evaluate the durability performance of concrete mixtures prepared utilizing blends of Type I Portland cement (OPC) and natural pozzolans (NPs) obtained from three different sources in Saudi Arabia. The control concrete mixture containing OPC alone as the binder and three concrete mixtures incorporating NPs were prepared keeping water/binder ratio of 0.4 (by weight), binder content of $370kg/m^3$, and fine/total aggregate ratio of 0.38 (by weight) invariant. The compressive strength and durability properties that included depth of water penetration, depth of carbonation, chloride diffusion coefficient, and resistance to reinforcement corrosion and sulfate attack were determined. Results of this study indicate that at all ages, the compressive strength of NP-admixed concrete mixtures was slightly less than that of the concrete containing OPC alone. However, the concrete mixtures containing NP exhibited lower depth of water penetration and chloride diffusion coefficient and more resistance to reinforcement corrosion and sulfate attack as compared to OPC. NP-admixed concrete showed relatively more depth of carbonation than OPC when subjected to accelerated carbonation. The results of this investigation indicates the viability of utilizing of Saudi natural pozzolans for improving the durability characteristics of concrete subjected to chloride and sulfate exposures.

마이크로파일로 보강된 프리캐스트 콘크리트 옹벽의 최적보강형태에 관한 연구 (A Study on Optimal Reinforcing Type of Precast Retaining Wall Reinforced by Micropiles)

  • 김홍택;박준용;유찬호
    • 한국지반공학회논문집
    • /
    • 제22권11호
    • /
    • pp.89-99
    • /
    • 2006
  • 프리캐스트 콘크리트 옹벽은 현장타설 콘크리트 옹벽에 비해 공기 단축효과, 품질의 우수성, 교통 및 인접구조물과의 간섭 최소화 등 많은 장점을 가지고 있다. 하지만 지반조건이 비교적 양호한 직접기초형태의 경우에는 별도의 보강조치를 고려하지 않으면 자중만으로 저항하게 됨에 따라 옹벽의 단면이 증가하게 되고 그에 따른 운반상의 어려움 및 공사비 증가 등의 단점이 있다. 본 연구에서는 이러한 문제점을 보완하기 위한 방법으로 마이크로파일공법의 적용성을 평가해 보았다. 마이크로파일공법은 소형장비로 시공이 가능하므로 작업공간의 제약이 없고, 저비용 및 고효율의 장점을 가지고 있으나 보강효과를 높이기 위해 설치한 마이크로파일의 역학적 거동특성이 명확히 규명되지 않은 상태이며, 마이크로파일의 길이, 직경, 설치각도 및 설치위치 등에 대한 설치기준이 없고 경험에 의존하고 있는 실정이다. 따라서 본 연구에서는 프리캐스트 콘크리트 옹벽에 보강된 마이크로파일의 최적보강형태 및 보강효과를 규명 제시하기 위하여 활동 및 전도거동에 대한 실내모형실험을 각각 시행하였다. 또한 실내모형실험 결과를 토대로 제시된 마이크로파일의 최적보강형태를 검증하기 위한 목적으로 유한요소해석 및 한계평형해석 등의 수치해석을 수행하여 마이크로파일의 최적 보강형태를 제시하였다. 실내모형실험과 수치해석으로 프리캐스트 콘크리트 옹벽에 보강되는 마이크로파일의 최적보강형태를 평가한 결과, 마이크로파일은 옹벽높이의 0.4배 저판길이의 0.04배 일 때가, 최적의 보강효율을 보이는 것으로 평가되었다.

Reasons for Variation in Sensitivity and Specificity of Visual Inspection with Acetic Acid (VIA) for the Detection of Pre-Cancer and Cancer Lesions of Uterine Cervix

  • Parashari, Aditya;Singh, Veena
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7761-7762
    • /
    • 2013
  • Alternative strategies such as visual inspection of cervix with acetic acid, are real time, economical and easily implemented methods for cervical cancer screening. However, variable sensitivity and specificity have been observed in various community based studies. The possible reasons could include variation in man power training, light source used for visualization, and preparation of diluted (4-5%) acetic acid and its storage. A standardized protocol for training, teaching material (easy to understand in the local language) for trainees, supervision and reinforcement by intermittent and supplementary training to check the quality of their observation, a standard protocol for preparation dilute acetic acid and its storage and a standard good light source (equivalent to day light) are needed to minimize the variation in sensitivity and specificity of VIA in community settings.

순환골재 및 Fiber를 사용한 원심력 콘크리트의 염소이온 및 탄산화 저항성에 대한 시험적 고찰 (An Experimental Study on Chlorine-ion and Carbonation Resistance of the Spun-Concrete Used Recycled Aggregate and Fiber)

  • 심종성;박철우;박성재;김현중;김태광
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.423-426
    • /
    • 2005
  • Until now, the quantity to recycle wasted concrete as the great supplementary value was very little. But considering a insufficiency of the present state of aggregates, the recycling of wasted aggregates is indispensable. Recycled aggregate is useful resources for concrete, but its application to structural member is not frequently. In this an experimental study here in, this study is to reinforcement orientation containing fiber of the spun-concrete using recycled aggregate, evaluation of designed chlorine-ion and carbonation resistance. The result of study chlorine-ion resistance by using replacement ratios ($0.00\%,\;0.01\%,\;0.03\%,\;0.05\%,\;0.08\%$) of fiber which it more increase. Carbonated thickness of the spun-concrete used fiber and the normal spun-concrete was similar or it appeared with the tendency which it diminishes.

  • PDF