Browse > Article
http://dx.doi.org/10.5345/JKIBC.2018.18.2.099

Proposals of Reliable Shapes of Supplementary V-ties for Section Jacketing Method of Columns  

Kwon, Hyuck-Jin (Department of Architectural Engineering, Kyonggi University)
Yang, Keun-Hyeok (Department of Plant.Architectural Engineering, Kyonggi University)
Sim, Jae-Il (4M Corp., Industry-Academia Collaboration Foundation, Dongshin University)
Publication Information
Journal of the Korea Institute of Building Construction / v.18, no.2, 2018 , pp. 99-107 More about this Journal
Abstract
The objective of the present study is to propose a reliable shape of supplementary V-ties in the section jacketing approach for seismic strengthening of reinforced concrete columns. A total of 24 pull-out specimens were prepared. The test parameters selected with regard to bond strength of V-ties were the shape of V-ties, embedment length of V-tie legs, and compressive strength of concrete. The measured bond strength of V-ties with different shapes were compared with that of the conventional V-ties and predictions using CEB-FIP equation. Ultimately, V-ties with pressed end-details at their legs could be recommended for the supplementary lateral reinforcement of strengthening columns with jacketing thickness less than the embedment length [= max (75mm, $6d_b$)] of conventional V-ties, where $d_b$ is the diameter of the reinforcing bar used for V-ties.
Keywords
V-tie; jacketing technique; supplementary lateral reinforcement; bond strength;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Dong JF, Wang QY, Guan ZW. Material properties of basalt fiber reinforced concrete made with recycled earthquake waste. Journal of Construction and Building Materials. 2017 Jan;130(1):241-51.   DOI
2 Jung JS. Seismic performance evaluation of medium and low-rise R/C buildings strengthened by RCSF-method [dissertation]. [Daejeon(Korea)]: Chonnam National University; 2015. 87 p.
3 Sun CG. Seismological and geotechnical characteristics of the 12 september 2016 Gyeongju earthquake. The Magazine of the Korean Society of Civil Engineers. 2017 Apr;65(4):14-9.
4 Liu J, Min D, Dong L, Xiuli D, Haibin X. Effects of cross section size and transverse rebar on the behavior of short squared RC columns under axial compression. Engineering Structures. 2017 Apr;142(1):223-39.   DOI
5 Yang KH. Lateral confinement effectiveness of V-shaped supplementary ties in RC columns subjected to axial compressive loads. Journal of the Architectural Institute of Korea Structure & Construction. 2016 Mar;32(3):11-8.   DOI
6 Troung GT, Kim JC, Choi KK. Seismic performance of reinforced concrete columns retrofitted by various methods. Engineering Structures. 2017 Mar;134(1):217-35.   DOI
7 Yang KH. Lateral confinement effectiveness of V-shaped supplementary ties in RC columns subjected to axial compressive loads. Journal of the Architectural Institute of Korea. 2016 Mar;32(3):11-18.
8 Kim WW, Yang KH. Effect of bending angle and embedment length on the bond characteristics of V-shaped tie reinforcement. Journal of the Korea Institute Building Construction. 2015 Oct 20;15(5):465-71.   DOI
9 Committee Euro-International Du Beton. CEB-FIP Model Code for Concrete Structure 1991. Thomas Telforld. 1991. 437 p.
10 Architectural Institute of Korea. Korea Building Code. Korea: Architectural Institute of Korea. 2016. 644 p.
11 Korean Industrial Standards. Standard test method for comparing concrete on the basis of the bond developed with reinforcing steel. Korea: Korean Standards Association; 2015. 9 p.
12 Testuya S, Masayasu O. Damage estimation of concrete canal due to earthquake effects by acoustic emission method. Journal of Construction and Building Materials. 2014 Sep;67(1):186-91.   DOI
13 Kim BJ, Jin IG, Choi HB, Kang KI. The effect of form oils on bond characteristics of reinforced concrete members. Journal of the Architectural Institute of Korea. 2007 Dec;23(12):89-96.