• Title/Summary/Keyword: supercritical water

Search Result 248, Processing Time 0.03 seconds

Phase Equilibria of Ionic Liquid/Organic Compound/Supercritical CO2 Systems (이온성액체/유기화합물/초임계이산화탄소계의 상평형)

  • Lim, Bang-Hyun;Kim, Jong-Won;Paek, Sang-Min;Son, Bo-Kook;Lee, Yong-Rok;Lee, Chul Soo;Lee, Huen;Ra, Chun-Sup;Shim, Jae-Jin
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.128-137
    • /
    • 2006
  • The volume change of an ionic liquid and the phase separation behavior of room temperature ionic liquid(RTIL)/organic compound mixture in supercritical carbon dioxide were measured in a high pressure view cell. 1-Butyl-3-methylimidazolium hexafluorophosphate ([bmim][$PF_6$]) and 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][$BF_4$]) was used as ionic liquid(IL). and methanol and dimethyl carbonate were used as organic compound. For a fixed amount of [bmim][$PF_6$] the lower critical endpoint (LCEP) pressure, where the liquid phase is split, decreased as increasing the amount of organic compound. The LCEP pressure became higher as the water content of ionic liquid was higher. However, for water contents above a certain value, no LCEP was formed. LCEP appeared 1.0 MPa higher for a mixture with [bmim][$BF_4$] than with [bmim][$PF_6$]. There was almost no difference in the K-point pressures for different types of ionic liquid and for different amounts of organic liquid. When the concentration of ionic liquid([bmim][$PF_6$]) (IL/(IL+MeOH)) in the initial liquid mixture was larger than 5.9 mol% at the LCEP of the mixture, the volume of $L_1$ because larger than the volume of $L_2$. When it was smaller, however, the volume became smaller, too. The volume change of ionic liquid in the presence of carbon dioxide decreased as increasing the temperature, while it increased as increasing the pressure. For temperatures between 313.15 to 343.15K at 300 bar, it was about 123~125 % of the original volume.

  • PDF

Swelling and Mechanical Property Change of Shale and Sandstone in Supercritical CO2 (초임계 CO2에 의한 셰일 및 사암의 물성변화 및 스웰링에 관한 연구)

  • Choi, Chae-Soon;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.22 no.4
    • /
    • pp.266-275
    • /
    • 2012
  • In this study, a method is devised to implement a supercritical $CO_2$ ($scCO_2$) injection environment on a laboratory scale and to investigate the effects of $scCO_2$ on the properties of rock specimens. Specimens of shale and sandstone normally constituting the cap rock and reservoir rock, respectively, were kept in a laboratory reactor chamber with $scCO_2$ for two weeks. From this stage, a chemical reaction between rock surface and the $scCO_2$ was induced. The effect of saline water was also investigated by comparing three conditions ($scCO_2$-rock, $scCO_2-H_2O$-rock and $scCO_2$-brine(1M)-rock). Finally, we checked the changes in the properties before and after the reaction by destructive and nondestructive testing procedures. The swelling of shale was a main concern in this case. The experimental results suggested that $scCO_2$ has a greater effect on the swelling of the shale than pure water and brine. It was also observed that the largest swelling displacement of shale occurred after a reaction with the $H_2O-scCO_2$ solution. The results of a series of the destructive and nondestructive tests indicate that although each of the property changes of the rock differed depending on the reaction conditions, the $H_2O-scCO_2$ solution had the greatest effect. In this study, shale was highly sensitive to the reaction conditions. These results provide fundamental information pertaining to the stability of $CO_2$ storage sites due to physical and chemical reactions between the rocks in these sites and $scCO_2$.

CORE AND SUB-CHANNEL EVALUATION OF A THERMAL SCWR

  • Liu, Xiao-Jing;Cheng, Xu
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.677-690
    • /
    • 2009
  • A previous study demonstrated that the two-row fuel assembly has much more favorable neutron-physical and thermal-hydraulic behavior than the conventional one-row fuel assemblies. Based on the newly developed two-row fuel assembly, an SCWR core is proposed and analyzed. The performance of the proposed core is investigated with 3-D coupled neutron-physical and thermal-hydraulic calculations. During the coupling procedure, the thermal-hydraulic behavior is analyzed using a sub-channel analysis code and the neutron-physical performance is computed with a 3-D diffusion code. This paper presents the main results achieved thus far related to the distribution of some neutronic and thermal-hydraulic parameters. It shows that with adjustment of the coolant and moderator mass flow in different assemblies, promising neutron-physical and thermal-hydraulic behavior of the SCWR core is achieved. A sensitivity study of the heat transfer correlation is also performed. Since the pin power in fuel assemblies can be non-uniform, a sub-channel analysis is necessary in order to investigate the detailed distribution of thermal-hydraulic parameters in the hottest fuel assembly. The sub-channel analysis is performed based on the bundle averaged parameters obtained with the core analysis. With the sub-channel analysis approach, more precise evaluation of the hot channel factor and maximum cladding surface temperature can be achieved. The difference in the results obtained with both the sub-channel analysis and the fuel assembly homogenized method confirms the importance of the sub-channel analysis.

Elastic and Superhydrophobic Monolithic Methyltrimethoxysilane-based Silica Aerogels by Two-step Sol-gel Process

  • Mahadik, D.B.;Jung, Hae-Noo-Ree;Lee, Yoon Kwang;Lee, Kyu-Yeon;Park, Hyung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2016
  • The flexible and superhydrophobic properties of silica aerogels are extremely important material for thermal insulation and oil spill cleanup applications for their long-term use. Flexible silica aerogels were synthesized by using a two-step sol-gel process with precursors, methyltrimethoxysilane (MTMS) followed by supercritical drying. Silica aerogels were prepared at different molar ratio of methanol to MTMS (M). It was observed that the silica aerogels prepared at M=28 were monolithic but inelastic in nature, however, for M=35, the obtained aerogels were monolithic, elastic in nature with less shrinkage. The microstructural studies were carried out using scanning electron microscopy and surface area measurements. The hydrophobicity was confirmed by Fourier transform Infrared spectroscopy and water contact angle measurements. The detailed insight mechanism for flexible nature of silica aerogels and hydrophobic behavior were studied.

Pancreas로부터 의약품 원료생산을 위한 초임계 추출

  • Gwon, Hyeok-Su;Jeon, Byeong-Su;Lee, Baek-Cheon;An, Byeong-Geun
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.516-519
    • /
    • 2000
  • Generally pancreas consist of lipid, water and protein, digestion enzyme complex (pro-tease, lipase, amylase). The sample used in this work was frozen dry and treated by a semi-batch flow type. In order to develop a supercritical fluid extraction process to rem-ove lipid from the pancreas, experiments were conducted at various operating conditions(pressure range $1500{\sim}2800psi$, temperature range $25{\sim}40^{cdot}C$, particle size$(0.25{\sim}1.0mm$, flow rate $20{\sim}80m{\ell}/min)$. Also cholesterol in the pancreas was removed. The highest extraction efficiency was 2500psi, $35^{\cdot}C$, 0.25mm of pancreas size. The enzyme activity of the pancreas produced from this work showed high value compared with imported pancreas.

  • PDF

Review : Ionic Liquids as Green Solvent (리뷰 : 녹색용매로서의 이온성액체 기술동향)

  • Lee, Junwung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.690-702
    • /
    • 2013
  • Ionic liquids(ILs) have been the most investigated chemicals among green solvents including water, glycerol, supercritical carbon dioxdie($scCO_2$). ILs are attracting organic as well as inorganic chemicals because most ionic liquids' vapor pressures are very low so that ILs are liquids phase at ambient conditions. ILs are composed of various anions and cations, thus chemists can design functionalized solvents and/or catalysts that can be used in specific synthetic reactions by means of combinations of different ions. Many scientists believe ILs being green materials because of its low vapor pressure as well as the flexibility in controlling the chemical and physical properties. In this review the author describes recent development of ILs focused on imidazolium and pyridinium ILs which are being most investigated presently. In order to apply this materials in industrial level, the toxicity matter must be resolved first. In this regard, the author describes recent research trend regarding environmental effects by ILs as well as some meaningful results as well.

Heat Transfer Characteristics of an Annulus Channel Cooled with R-134a Fluid near the Critical Pressure (임계압력 근처에서의 환형관 채널에 대한 열전달 특성 연구)

  • Hong, Sung-Deok;Chun, Se-Young;Kim, Se-Yun;Baek, Won-Pil
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2094-2099
    • /
    • 2004
  • An experimental study on heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with the increase of the system pressure For a fixed inlet mass flux and subcooling, the CHF falls sharply at about 3.8 MPa and shows a trend toward converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall because the CHF occurred at remarkably low power levels. In the pressure reduction transient experiments, as soon as the pressure passed through the critical pressure, the wall temperatures rise rapidly up to a very high value due to the occurrence of the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, then tends to decrease gradually.

  • PDF

Low Temperature Selective Catalytic Reduction of NO with $NH_3$ over Mn/$CeO_2$ and Mn/$ZrO_2$ (Mn/$CeO_2$와 Mn/$ZrO_2$ 촉매 상에서 $NH_3$를 사용한 NO의 선택적 촉매 산화 반응)

  • Ko, Jeong Huy;Park, Sung Hoon;Jeon, Jong-Ki;Sohn, Jung Min;Lee, See-Hoon;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.105-111
    • /
    • 2012
  • Manganese (Mn) catalysts were generated using $CeO_2$ and $ZrO_2$supports synthesized by the supercritical hydrothermal method and two different Mn precursors, aimed at an application for a low-temperature selective catalytic reduction process. Manganese acetate (MA) and manganese nitrate (MA) were used as Mn precursors. Effects of the kind and the concentration of the Mn precursor used for catalyst generation on the NOx removal efficiency were investigated. The characteristics of the generated catalysts were analyzed using $N_2$ adsorption-desorption, thermo-gravimetric analysis, X-ray diffraction, and X-ray photoelectron spectroscopy. De-NOx experiments were carried out to measure NOx removal efficiencies of the catalysts. NOx removal efficiencies of the catalysts generated using MA were superior to those of the catalysts generated using MN at every temperature tested. Analyses of the catalyst characteristics indicated that the higher NOx removal efficiencies of the MA-derived catalysts stemmed from the higher oxygen mobility and the stronger interaction with support material of $Mn_2O_3$ produced from MA than those of $MnO_2$ produced from MN.

Heat Integration and Economic Analysis of Dry Flue Gas Recirculation in a 500 MWe Oxy-coal Circulating Fluidized-bed (CFB) Power Plant with Ultra-supercritical Steam Cycle (순환 유동층 보일러와 초초임계 증기 사이클을 이용한 500 MWe급 순산소 화력발전소의 건식 재순환 흐름의 열 교환 및 경제성 분석)

  • Kim, Semie;Lim, Young-Il
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • This study presented techno-economic analysis of a 500 MWe oxy-coal power plant with CO2 capture. The power plant included a circulating fluidized-bed (CFB), ultra-supercritical steam turbine, flue gas conditioning (FGC), air separation unit (ASU), and CO2 processing unit (CPU). The dry flue gas recirculation (FGR) was used to control the combustion temperature of CFB. One FGR heat exchanger, one heat exchanger for N2 stream exiting ASU, and a heat recovery from CPU compressor were considered to enhance heat efficiency. The decrease in the temperature difference (ΔT) of the FGR heat exchanger that means the increase in heat recovery from flue gas enhanced the electricity and exergy efficiencies. The annual cost including the FGR heat exchanger and FGC cooling water was minimized at ΔT = 10 ℃, where the electricity efficiency, total capital cost, total production cost, and return on investment were 39%, 1371 M$, 90 M$, and 7%/y, respectively.

Explicit solutions for alternate depth in parabolic open channel (포물선형 개수로에서 대응수심의 양해적 산정)

  • Kim, Dae Geun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.326-326
    • /
    • 2017
  • 개수로에서 비에너지(specific energy)는 수로바닥을 기준으로 단위무게의 물이 가지는 에너지로 정의되며 흐름의 위치수두와 속도수두의 합으로 표현된다. 비에너지는 수로단면의 변화에 따른 수심의 변화를 해석하기 위하여 사용되는 중요한 개념이다. 사각형 개수로에서의 비에너지 관계식은 3차방정식의 형태이며, 해석적으로 3개의 해(3개의 수심)를 가지나, 물리적인 의미를 가지는 해는 2개이며 나머지 하나의 해는 음수이므로 물리적인 의미를 가지지 않는다. 물리적인 의미를 가지는 2개의 해는 각각 흐름이 상류(subcritical flow)인 경우와 사류(supercritical flow)인 경우에 대한 수심이다. 즉, 일정한 유량이 흐르는 조건에서 동일한 비에너지를 가지는 수심이 상류와 사류에 각각 존재하는데, 이 2개의 수심을 대응수심(alternate depths)이라 정의한다. 이러한 사각형 개수로에 대한 비에너지 관계식은 3차방정식이므로 그 해석해를 구할 수 있어, 수로단면의 변화에 따른 흐름의 변화를 비교적 쉽게 해석할 수 있다. 사각형 개수로가 아닌 경우의 비에너지 관계식을 이론적으로 고찰하는 연구는 찾아보기 힘들다. 이에 본 연구에서는 포물선형 개수로에 대해서 비에너지 관계식을 유도하였다. 유도된 비에너지 관계식은 비선형 음함수의 형태로 해석적으로 해를 구할 수 없다. 유도된 관계식의 해법으로 2차의 정밀도를 가지는 Newton-Raphson방법을 이용하였으며, 계산의 초기치는 상용화된 Excel에서 쉽게 구할 수 있는 회귀식을 이용하여 구하였다. 적용 예를 통해, 단순 회귀식을 이용하는 경우에는 정해와의 상대오차가 2 - 8% 내외였는데, 본 연구에서 제안하는 방법을 사용하는 경우에는 동일한 조건에서 상대오차가 0.25% 내외를 보였다. 즉 본 연구에서 제시하고 있는 양해법을 이용하면, 포물선형 개수로 흐름의 대응수심을 용이하게 그리고 정확도가 매우 높게 산정할 수 있다.

  • PDF