저온에서 정방형 공간내 성층화된 유체의 열적거동에 관한 실험적 연구 (An Experimental Study on the Low-Temperature Behavior of Stratified Fluids in the Square Cavity)

  • 강한용;이동석;김병철
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.381-387
    • /
    • 2000
  • An experimental study on the stratified fluids was carried out to investigate the flow characteristics, heat transfer through the interface of fluids, and the applications of thermal behaviors in the square cavity. The same volume of water and silicon oil was filled in it. The experiments were performed with the variations of initial temperatures and cooling surface temperatures. And the effect of vertical or horizontal cooling surface positions in the square cavity was investigated. When the cooling surface temperatures were $-4^{\circ}C$ , the supercooling phenomena were observed for both cases of cooling surface positions in the full region regardless of the initial temperature of fluid. In the square cavity with horizontal cooling surfaces, the lower the initial temperatures were, the longer the supercooling durations were, and with vertical cooling surface the lower the initial temperatures were, the shorter the supercooling durations were.

  • PDF

포접화합물의 열물성에 미치는 첨가제의 효과 (II) -TMA 물계 포접화합물에 Ethylene Glycol을 첨가한 경우- (The Effects of Additives on the Thermal Properties of a Clathrate Compound (II) -The Case of Ethylene Glycol-)

  • 정낙규;김진흥;김창오;김광일
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.499-505
    • /
    • 2004
  • The objective of this study is to investigate the effect of supercooling repression on the TMA clathrate by adding ethylene glycol. For this purpose, phase change temperature, supercooling, specific heat, latent heat and rate of volume change were measured and evaluated experimentally for heat source temperatures of -6$^{\circ}C$, -7$^{\circ}C$, -8$^{\circ}C$. The results show that supercooling was decreased. Thus the experimental results are expected to be used for the increase of coefficient of performance of low temperature thermal storage system in the building.

첨가제를 첨가한 저온축열물질의 냉각특성에 대한 연구 (A Study on Cooling Characteristics of Low Temperature Thermal Storage Material with Additives)

  • 정낙규;김진흥;정종헌;김창오;강승현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1746-1750
    • /
    • 2004
  • The objective of this study is to investigate the effect of supercooling repression on the clathrate compound by adding additives. For this purpose, phase change temperature and supercooling were measured when additives added to TMA30wt% clathrate for heat source temperature of $-6^{\circ}C$. The experimental results show that the phase change temperature with the chloroform of 0.1wt% is higher by $0.3^{\circ}C$ than TMA30wt% and the supercooling with the surfactant 0.1wt% is reduced by $9.2^{\circ}C$.

  • PDF

티타늄 산화물강 열영향부 조직변태에 미치는 망간 및 탄소의 영향 (Effects of Manganese and Carbon on the HAZ Microstructural Evolution in Titanium Oxide Steel)

  • 방국수
    • Journal of Welding and Joining
    • /
    • 제22권2호
    • /
    • pp.78-84
    • /
    • 2004
  • Effects of manganese and carbon on the HAZ microstructural evolution in 500㎫ grade titanium oxide steels were investigated. Microstructural evolution primarily depends on supercooling. When cooled at 3$^{\circ}C$/s in 0.15%C-1.5%Mn steel, grain boundary and Widmanst tten ferrite formed at 640 and 62$0^{\circ}C$, respectively, followed by competitive formation of acicular ferrite and upper bainite inside of grain at 58$0^{\circ}C$. With an increase of manganese, degree of supercooling increased while critical cooling rate for the formation of gain boundary ferrite decreased. Consequently, the amount of acicular ferrite in HAZ was decreased in 2.0%Mn after initial increase in 1.0 and 1.5%Mn. Therefore, optimum supercooling should be maintained to accelerate acicular ferrite formation in titanium oxide steels. Low carbon steel, 0.11%C-1.5%Mn, showed larger amount of acicular ferrite than higher carbon steel because of effectiveness of diffusionless transformation in low carbon steel.

저온축열물질의 열물성에 미치는 첨가제의 영향 (The Effects of Additives on the Thermal Properties of a Low Temperature Thermal Storage Material)

  • 강승현;김진홍;정낙규;김창오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1165-1170
    • /
    • 2004
  • The purpose of this study is to investigate the supercooling improvement of TMA30wt% clathrate when the chloroform is added to it. For this purpose, phase change temperature and supercooling are measured and evaluated experimentally in heat source of $-7^{/circ}C$. The results show that phase change temperature and supercooling are improved. From the results, this research can provide and important data for the low temperature thermal storage.

  • PDF

가압조건이 정지상태 과냉각 수용액의 해소에 미치는 영향 (Effect of pressurization on dissolution of a supercooled aqueous solution with a stationary state)

  • 김병선;백종현;홍희기;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.132-137
    • /
    • 2006
  • Supercooled type ice slurry system is hard to keep a proper supercooling degree when solution becomes supercooling state. This is the reason of the ice blockage in pipe or cooling part due to an unstable cooling state. In this study, a cooling experiment was performed to pressurized solution in a stationary state. The behaviors during the supercooled aqueous solution were investigated at fixed flow rate of brine and aqueous solution of ethylene glycol 7 mass%. Also the effect to the freezing point of supercooled aqueous solution was investigated to the different pressure 101, 202, 303, and 404 kPa. At results, the pressure of the aqueous solution in the cylinder increased the supercooling degree increased and dissolution of supercooled point decreased.

  • PDF

에탄올에 의한 TMA-포접화합물의 냉각특성 개선에 대한 연구 (A Study on the Cooling Characteristics Improvement of TMA-Water Clathrate Compound by Ethanol)

  • 이종인;김창오
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.23-28
    • /
    • 2007
  • This study aims to find out cooling characteristics of TMA(Tri-Methyl-Amine, $(CH_3)_3N$) 25wt%-water clathrate compound with ethanol($CH_3CH_2OH$) such as supercooling, phase change temperature and specific heat. For this purpose, ethanol is added as per weight concentration and cooling experiment is performed at $-6{\sim}-8^{\circ}C$, cooling heat source temperature, and it leads the following result. (1) Phase change temperature is decreased due to freezing point depression phenomenon. Especially, it is minimized as $3.8^{\circ}C$ according to cooling source temperature in case that 0.5wt% of ethanol is added. (2) If 0.5wt% of ethanol is added, average supercooling degree is $0.9^{\circ}C$ and minimum supercooling is 0.8, $0.7^{\circ}C$ according to cooling heat source temperature. The restraint effect of supercooling is shown. (3) Specific heat shows tendency to decrease if ethanol is added. It is $3.013{\sim}3.048\;kcal/kg^{\circ}C$ according to cooling heat source temperature if 0.5wt% of ethanol is added. Phase change temperature higher than that of water and inhibitory effect against supercooling can be confirmed through experimental study on cooling characteristics of TMA 25wt%-water clathrate compound by adding additive, ethanol. This can lead to shorten refrigerator operation time of low temperature latent heat storage system and improve COP of refrigerator and efficiency of overall system. Therefore energy can be saved and efficiency can be improved much more.

저온잠열저장을 위한 TMA-물계 포접화합물의 냉각특성에 대한 연구 (A Study on Cooling Characteristic of TMA-Water Clathrate Compound for Low Temperature Latent Heat Storage)

  • 김창오;김진흥;정낙규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2471-2475
    • /
    • 2007
  • Clathrate compound is the material that host in hydrogen bond forms cage and guest is included into it and combined. Crystallization of hydrate is generated at higher temperature than that of ice from pure water. And physical properties according to temperature are stable and congruent melting phenomenon is occurred without phase separation. But clathrate compound still had supercooling problem occurred in the course of phase change and supercooling should be minimized because it affects efficiency of equipment very much. Therefore, various studies on additives to restrain this or heat storage methods are needed. In this study was investigated the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N)$ of 20${\sim}$25 wt% as a low temperature latent heat storage material. And ethanol$(CH_3CH_2OH)$ was added and its cooling characteristics were studied experimentally to restrain supercooling of TMA-water clathrate compound.

  • PDF

저온잠열축열을 위한 TMA-물계 포접화합물의 냉각특성 (TMA-Water Clathrate Compound of Cooling Characteristics for Low Temperature Latent Heat Storage)

  • 김창오;정현호;정낙규
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.296-301
    • /
    • 2009
  • The ice storage system uses water for low temperature latent heat storage. However, a refrigerator capacity is increased and COP is decreased due to supercooling of water in the course of phase change from solid to liquid. This study investigates the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N)$ of $20{\sim}25wt%$ as a low temperature latent heat storage material. The results showed that the phase change temperature and the specific heat is increased and the supercooling degree is decreased as the weight concentration of TMA increased. Especially, the clathrate compound containing TMA 25wt% has the average phase change temperature of $5.8^{\circ}C$, the supercooling degree of $8.0^{\circ}C$ and the specific heat of 3.499 kJ/kgK in the cooling process. This can lead to reduction of operation time of refrigerator in low temperature latent heat storage system and efficiency improvement of refrigerator COP and overall system. Therefore, energy saving and improvement of utilization efficiency are expected.

  • PDF

R141b 포접화합물을 이용한 축냉시스템의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Cool Storage System using R141b Clathrate)

  • 정인성;김양규;이준식;노승탁
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.354-364
    • /
    • 1994
  • Experiments have carried out to investigate the effects of parameters, such as mass ratio of R141b-to-water, stirrer speed, brine inlet temperature, brine flowrate, and additives, on the performance of the cool storage system using R141b clathrate. The cool storage system in this experiment was composed of storage tank, refrigerator, and heater. The results show that the mass ratio of R141b-to-water, 1 : 3~1 : 3.5 gives the best performance and the stirring speed has optimum point as 600rpm. At this speed impeller Reynolds number is $1.01{\times}10^5$. The lower the inlet brine temperature and the highter the brine flowrate, the better performance. The addition of metal powder turned out to reduce the degree of supercooling. The supercooling reduction was proportional to the amount of the metal power. However when metal powder was added more than 0.1 wt%, there was no additional supercooling reduction. The surfactants shortened the time consumed for cool storage to the half of no surfactant added case.

  • PDF