• Title/Summary/Keyword: superconducting quantum interference device (SQUID)

Search Result 79, Processing Time 0.024 seconds

Reconstruction of Myocardial Current Distribution Using Magnetocardiogram and its Clinical Use (심자도를 이용한 심근 전류분포 복원과 임상적 응용)

  • 권혁찬;정용석;이용호;김진목;김기웅;김기영;박기락;배장호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.459-464
    • /
    • 2003
  • The source current distribution in a heart was reconstructed from the magnetocardiogram (MCG) and its clinical usefulness was demonstrated. MCG was measured using 40-channel superconducting quantum interference device (SQUID) gradiometers for a patient of Wolff-Parkinson-White (WPW) syndrome, which has an accessory pathway between the atria and the ventricles. Reconstruction of source current distribution in a plane below the chest surface was performed using minimum norm estimation (MNE) algorithm and truncated singular value decomposition (SVD), In the simulation, we confirmed that the current distributions. which were computed for the test dipoles, represented well the essential feature of the test current configurations, In the current map of WPW syndrome, we observed abnormal currents that would bypass the atrioventricular junction at a delta wave. However, we could not observe such currents any more after the surgery. These results showed that the obtained current distribution using MCG signals is consistent with the electrical activity in a heart and has clinical usefulness.

High sensitive SQUID sensor on YBCO thin film (YBCO 박막을 이용한 고감도 SQUID 센서)

  • ;;K.NM. Yugay;A.B. Muravjev;K.K. Yugay;G.M.Serojan;A.S.Sjichev
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.758-761
    • /
    • 2003
  • The goal of the research is to study and describe a new stressed state of High Temperature Superconducting (High-T$_{c}$) YBCO Films, to create of SQUIDs (Superconducting Quantum Interference Device) on the bases of these films with maximal sensitivity. With the experimental investigation of the stressed films grown by laser ablation method and its properties, the fabrication of the dc-SQUIDs with maximal sensitivity on the bases of the stressed YBCO films were carried out. The stressed film having the value of the critical current density J$_{c}$=3ㆍ$10^{5}$A/$\textrm{cm}^2$ was the more stable than others.ers.s.

  • PDF

Emulator Circuit for a Flux Locked Loop for Detection of Magnetocardiography Signal (심자도 신호 검출을 위한 Flux Locked Loop (FLL) Emulation 회로)

  • 안창범;이동훈;김인기;장경섭;김기태;정동현;최중필
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2749-2752
    • /
    • 2003
  • Magnetocardiography is a very weak biomagnetic field generated from the heart. Since the magnitude of the biomagnetic field is in the order of a few pico Tesla, it is measured with a superconducting quantum interference device (SQUID). SQUID is a transducer converting magnetic flux to voltage, however, its range of linear conversion is very restricted. In order to overcome the narrow dynamic range. a flux locked loop is used to feedback the output field with opposite polarity to the input field so that the total Held becomes zero. This prevents the operating point of the SQUID from moving too far away from the null point thereby escape from the linear region. In this paper, an emulator for the SQUID sensor and feedback coil is proposed. Magnetic courting between the original field and the generated field by the feedback coil is emulated by electronic circuits. By using the emulator, FLL circuits are analyzed and optimized without SQUID sensors. The emulator may be used as a test signal for multi-channel gain calibration and system maintenance.

  • PDF

A Single-Flux-Quantum Shift Register based on High-$T_c$ Superconducting Step-edge Josephson Junctions

  • Sung G.Y.;Choi, C.H.;Suh J.D.;Han, S. K.;Kang, K.Y.;Hwang, J.S.;Yoon, S.G.;Jung, K.R.;Lee, Y.H.;Kang, J.H.;Kim, Y.H.;Hahn, T.S.
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.31-35
    • /
    • 1999
  • We have fabricated and tested a simple circuit of the rapid single-flux-quantum(RSFQ) four-stage shift register using a single layer high-$T_c$ superconducting (HTS) $YBa_2Cu_3O_{7-x}$ (YBCO) thin film structure with 9 step-edge Josephson junctions. The circuit includes two read superconducting quantum interference devices(SQUID) and four stages. To establish a robust HTS RSFQ device fabrication process, we have focussed on the reproducible process of sharp and straight step-edge formation as well as the ratio of film thickness to step height, t/h. The spread of step-edge junction parameters was measured from each 13 junctions with t/h=1/3, 1/2, and 2/3 at various temperatures. We have demonstrated the simplified operation of the shift register at 65 K.

  • PDF

Magnetism in the Layered Structure Compound (C_18H_37NH_3)_2 MNCL_4

  • Lee, K. W.;Lee, C. H.;C. Rhee;Lee, Cheol-Eui;J. K. Kang;Lee, K.-S.
    • Journal of Magnetics
    • /
    • v.2 no.4
    • /
    • pp.126-129
    • /
    • 1997
  • We have studied magnetostructural phase transitions in the perovskite-type layered structure compound (C18H37NH3)2 MnCl4 by means of electron paramagnetic resonance (EPR) and superconducting quantum interference device (SQUID) measurements. Distinct slopes were observed in the linear temperature dependences of the Mn++ EPR linewidth in the low and high temperature phases. Besides, linewidth anomalies at the transition temperatures sensitively reflect the magnetic changes arising from the MnCl6 octahedra.

  • PDF

Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System (저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작)

  • Kim I. S;Yu K. K;Park Y. K
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF

Development of High-Field ESR System Using SQUID Magnetometer and its Application to Measurement under High Pressure

  • Sakurai, T.;Fujimoto, K.;Okubo, S.;Ohta, H.;Uwatoko, Y.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.168-172
    • /
    • 2013
  • We have developed a high-field and high-frequency ESR system using a commercially available magnetometer equipped with the superconducting quantum interference device (SQUID). This is magnetization detection type ESR and ESR is observed as a change of the magnetization at the resonance condition under irradiation of the electromagnetic wave. The frequency range is from 70 to 315 GHz and the maximum magnetic field is 5 T. The sensitivity is estimated to be $10^{13}$ spins/G. The advantage of this system is that the high-field ESR measurements can be made very easily and quantitatively. Moreover, this high-field ESR can be applied to the measurements under pressure by using a widely used piston-cylinder pressure cell.

A Single-Flux-Quantum Shift Register based on High-T$_c$ Superconducting Step-edge Josephson Junctions

  • Sung, G.Y.;Choi, C.H.;Suh, J.D.;Han, S.K.;Kang, K.Y.;Hwang, J.S.;Yoon, S.G.;Jung, K.R.;Lee, Y.H.;Kang, J.H.;Kim, Y.H.;Hahn, T.S.
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.133-133
    • /
    • 1999
  • We have fabricated and tested a simple circuit of the rapid single-flux-quantum(RSFQ) four-stage shift register using a single layer high-T$_c$ superconducting (HTS) YBa$_2Cu_3O_{7-x}$ (YBCO) thin film structure with 9 step-edge Josephson junctions. The circuit includes two read superconducting quantum interference devices(SQUID) and four stages. To establish a robust HTS RSFQ device fabrication process, we have focussed the reproducible process of sharp and straight step-edge formation as well as the ratio of film thickness to step height t/h. The spread of step-edge junction parameters was measured from each13 junctions with t/h=l/3, l/2, and 2/3 at various temperatures. We have demonstrated the simplified operation of the shift register at 65 K..

  • PDF