• Title/Summary/Keyword: super-tall building

Search Result 130, Processing Time 0.025 seconds

Vertical coherence functions of wind forces and influences on wind-induced responses of a high-rise building with section varying along height

  • Huang, D.M.;Zhu, L.D.;Chen, W.;Ding, Q.S.
    • Wind and Structures
    • /
    • v.21 no.2
    • /
    • pp.119-158
    • /
    • 2015
  • The characteristics of the coherence functions of X axial, Y axial, and RZ axial (i.e., body axis) wind forces on the Shanghai World Trade Centre - a 492 m super-tall building with section varying along height are studied via a synchronous multi-pressure measurement of the rigid model in wind tunnel simulating of the turbulent, and the corresponding mathematical expressions are proposed there from. The investigations show that the mathematical expressions of coherence functions in across-wind and torsional-wind directions can be constructed by superimposition of a modified exponential decay function and a peak function caused by turbulent flow and vortex shedding respectively, while that in along-wind direction need only be constructed by the former, similar to that of wind speed. Moreover, an inductive analysis method is proposed to summarize the fitted parameters of the wind force coherence functions of every two measurement levels of altitudes. The comparisons of the first three order generalized force spectra show that the proposed mathematical expressions accord with the experimental results well. Later, the influences of coherence functions on wind-induced dynamic responses are analyzed in detail based on the proposed mathematical expressions and the frequency-domain method of random vibration theory.

The Influence of the Type of Silica Fume on the Property of Cement Binder for Ultra High Strength (초고강도용 시멘트 결합재의 물성에 미치는 실리카퓸 종류의 영향)

  • Kim, Ki-Hoon;Hwang, Yin-Seong;Kim, Sung-Su;Choi, Sung-Yong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.51-54
    • /
    • 2007
  • This study investigates the properties of paste and mortar from different types and forms of silica fume on cement binder for ultra high strength. Although most Silica Fumes distributed in the market fulfill the KS quality standard, each type showed different levels of loss of ignition. When evaluating cement binder for ultra high strength in a form of paste. Flow, viscosity and moving freely time show great difference depending on the Silica Fume's form and type of primary particle's dispersibility. The evaluation of Silica Fume's dispersibility can be possible with the paste test since there is a high correlation of flow quality between paste and mortar. The compressive strength when using Silica Fume was correlated to the SiO2 content. Synthetically, selecting Silica Fume with the most the ideal primary particle is the key to optimizing the formation for cement binder for ultra high strength.

  • PDF

A Study on the Unit Type BIPV Design Method for Super-Tall Building Concentrating on the Solar Irradiance Incident on the Building Facades (수직면 일사량을 고려한 초고층 건축물 적용 Unit형 BIPV 설계 방안에 관한 연구)

  • Liu, Chun-De;Seo, Young-Seok;Oh, Min-Seok;Kim, Hway-Suh
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.370-375
    • /
    • 2011
  • BIPV시스템 분야는 다른 PV 적용 기술 분야에 비해 빠르게 성장하고 있으나 소형 건축물 위주로 적용되었으며, 초고층 건축물과 같이 수직적으로 높은 건축물의 외부환경조건에 대응하기 위한 BIPV의 적용 방안은 현재까지 연구되어지지 않았다. 국내의 경우 선진국에 비해 초고층 건축물에 대한 BIPV시스템 적용기술은 아직 초기 연구단계에 불과하다. 초고층 건축물의 고유의 특징을 고려하여 초고층 건축물 파사드에 입사하는 일사량의 분포가 균일하지 않을 것이라고 예측하고 실측을 진행하였으며, 실측 결과의 분석을 통하여 초고층 건축물에서의 BIPV시스템 최적 설계방안을 제시하였다. 결론적으로 본 연구에서는 초고층 건축물의 외벽에 입사하는 일사량을 고려한 Unit형 BIPV설계 방안을 제시하였으며, 특히, 측정된 일사량 데이터를 활용하여 초고층 건축물에 적합한 인버터의 선정의 대안을 제시하였다.

  • PDF

Effect of the Various Combinations of the Binders and the Silica Fume Types to the Physical Properties of the Pre-Mix Cement (프리믹스 시멘트의 물리적 특성에 미치는 결합재조합 및 실리카퓸 종류의 영향)

  • Jin, Cheng-Ri;Kim, Ki-Hoon;Pei, Chang-Chun;Lee, Hai-III;Kim, Sung-Su;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.37-40
    • /
    • 2007
  • This study investigates the effect of the pre-mix cement to the physical properties of the concrete according to the various combinations of the binders and the silica fume types. The results are summarized as following. For the properties of the fresh, the fluidity in the case that OPC+cilica fume-blast-furnace slag is appropriate compared to OPC+cilica fume+fly ash. Expecially, it is favorable when pre-mix is used. The fluidity time of the A, B depending on silica fume types is favorable, but it is decreased on C. The air content depending on silica fume types is low when the fly ash is used. Specially, the air content in the case that pre-mix is used is low caused by the dispersion of the silica fume. For the properties of the hardened concrete, the compressive and flexible strength when the blast-furnace slag is pre-mixed are high, and they exceed OPC. The strength depending on the silica fume types is high on B, and the strength of the others is similar.

  • PDF

Control Performance Evaluation of Mid-Story Isolation System for Residence-Commerce Complex Building (주상 복합 구조물에 적용된 중간층 면진 시스템의 성능 검토)

  • Park, Kwang-Seob;Kim, Yun-Tae;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.33-40
    • /
    • 2019
  • A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.

Characteristics of Aerodynamic Damping on Helical-Shaped Super Tall Building (나선형 형상의 초고층건물의 공력감쇠의 특성)

  • Kim, Wonsul;Yi, Jin-Hak;Tamura, Yukio
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • Characteristics of aerodynamic damping ratios of a helical $180^{\circ}$ model which shows better aerodynamic behavior in both along-wind and across-wind responses on a super tall building was investigated by an aeroelastic model test. The aerodynamic damping ratio was evaluated from the wind-induced responses of the model by using Random Decrement (RD) technique. Further, various triggering levels in evaluation of aerodynamic damping ratios using RD technique were also examined. As a result, it was found that when at least 2000 segments were used for evaluating aerodynamic damping ratio for ensemble averaging, the aerodynamic damping ratio can be obtained more consistently with lower irregular fluctuations. This is good agreement with those of previous studies. Another notable observation was that for square and helical $180^{\circ}$ models, the aerodynamic damping ratios in along-wind direction showed similar linear trends with reduced wind speeds regarding of building shapes. On the other hand, for the helical $180^{\circ}$ model, the aerodynamic damping ratio in across-wind direction showed quite different trends with those of the square model. In addition, the aerodynamic damping ratios of the helical $180^{\circ}$ model showed very similar trends with respect to the change of wind direction, and showed gradually increasing trends having small fluctuations with reduced wind speeds. Another observation was that in definition of triggering levels in RD technique on aerodynamic damping ratios, it may be possible to adopt the triggering levels of "standard deviation" or "${\sqrt{2}}$ times of the standard deviation" of the response time history if RD functions have a large number of triggering points. Further, these triggering levels may result in similar values and distributions with reduced wind speeds and either may be acceptable.

Performance Evaluation of Fire Resistance of High Strength Concrete by Incorporation of Combined Fiber (복합섬유 혼입에 따른 고강도콘크리트의 내화 성능 평가)

  • Shin, Jae-Kyung;Park, Jong-Ho;Jeong, Yong;Moon, Hyung-Jae;Kim, Jeong-Jin;Park, Soon-Jeon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.423-424
    • /
    • 2010
  • This study purpose is to develop the high fireproof concrete which applied method of combined fiber mixed with polymer powder and organic fiber which can satisfy flowability and the fire resistance properties for construction of the super tall building. According to the results, in case of polymix it is effective to the reduction of internal temperature rise and spalling resistance so it as fire resistance that is similar to existing fiber cocktail.

  • PDF

Noise Management Process for Big Scale Concrete Pouring in Urban Area (도심지 대규모 콘크리트 타설시 소음관리 사례)

  • An, Jang-Ho;Lee, Joo-Ho;Lee, Jun-Seo;Kim, Il-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.787-790
    • /
    • 2012
  • In downtown, construction noise related claims are the most important issues. Sometimes noise related claims halt the construction process. Therefore, Introduction of noise reduction measures is common to construction process with a loud noise. This case is about concrete pouring for mat foundation of super tall building. Concrete pouring process using High Pressure Pumping machine causes high noise level in the vicinity of area. And large number of transit-mixer truck cause traffic congestion. This paper introduces effort and process to prevention of construction noise claims on massive scale concrete pouring.

  • PDF

An Experimental Study on Fire Performance of Curtain Walls in Super Tall Building (초고층용 커튼월 내화성능 평가를 위한 실험적 연구)

  • Jang, Seung-Bae;Kim, Heoung-Youl;Kim, Hyung-Jun;Lee, Jae-Sung;Cho, Bong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.345-350
    • /
    • 2011
  • 본 연구에서는 건축물의 초고층화와 대형화로 접목된 커튼월을 모델로 선정하여 알루미늄과 스틸 커튼월의 성능 비교를 위한 화재실험을 실시하였다. 화재실험은 $3m{\times}3m$ 규모의 알루미늄과 스틸 재질로 제작하여, 차염성, 차열성, 방열성, 변위, 커튼월 파괴를 측정하였다. 실험결과 알루미늄커튼월의 차염성은 12분, 차열성은 6분, 방열성은 26분을 기록하였고 스틸커튼월의 차염성은 10분, 차열성은 6분, 방열성은 14분을 기록하였다.

  • PDF

An Evaluation of Mechanical Properties of Ultra High Strength Concrete(UHSC) (초고강도 콘크리트의 재료역학적 특성 평가)

  • Lim Hee Jae;Shin Sung Woo;Ahn Jong Mun;Lee Kwang Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.281-284
    • /
    • 2004
  • The most important reason of using of ultra high strength concrete in super tall building is that ultra high strength concrete can reduce the section of members and control side sway effectively. However, the practical utilization of ultra high strength concrete is dependent not only on the production techniques, but also the overall preparation including proper code provisions, construction technique. The purpose of this study is to evaluate of mechanical properties of UHSC, such as modulus of elasticity, stress-strain behavior, modulus of rupture and tensile splitting strength. It is similar to normal or high strength concrete but necessary to discern the difference between normal or high strength concrete and ultra high strength concrete and modify existed equations. And in this study another important factor is to discern the difference according to member size, curing method in ultra high strength concrete experimentally.

  • PDF