• Title/Summary/Keyword: sum of temperature

Search Result 225, Processing Time 0.027 seconds

The Crystallograpic and Magnetic Properties of EuFeO3 Doped with in ions (In 이온을 첨가한 $EuFeO_{3}$의 결정구조 및 자기적 성질)

  • 김정기;서정철;한은주
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.4
    • /
    • pp.335-339
    • /
    • 1994
  • The crystallograpic and magnetic properties of $Eu(Fe_{1-x}In_{x})O_{3}$ (x=0, 0.03과 0.05) have been studied by the methods of X-ray diffraction, $M\"{o}ssbauer$ spectroscopy, and magnetic hysteresis measurement at room temperature. The X-ray results show that the samples have a crystal structure of orthorhombic and unit cell volume of the crystal with the exception of the sample of x=0 increases as increasing the In concentration. In the analysis assuming two sets of six-line of $M\"{o}ssbauer$ spectra, it is found that the magnetic hyperfine field in each of sets decreases increasing x. The linewidth of the absorption lines for the samples increased as increasing x. This implies that the data involve a sum of several hyperfine patterns which have intensity being proportional to $_{n}P_{z}(x)$, the probability of an environment with z such Fe neighbors. The magnetic hysteresis curves show decrease of $M_{s}$ and increase of $H_{c}$ of the samples with increasing x.

  • PDF

Development of PLC by using micro controller for the distributed fire alarm system (마이크로 콘트롤러를 이용한 분산형 방재 시스템용 중계기 개발)

  • Han, Kyong-Ho;Lee, Ki-Sik;Hwang, Seok-Yong;Kim, Jong-Chol
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1243-1247
    • /
    • 1996
  • In this paper, a small PLC system is designed and developed for the distributed building control and fire control system. It uses 8031, a 8-bit micro controller from Intel Inc. The size of the PLC is $7cm{\times}8cm$ and the PLC can accept 4 sensor inputs and drive 4 relay outputs, which operates at 24V. Multiple access of PLC by one host computer is implemented by assigning a unique 10 to each PLC, which ranges from 0 to 126. The operation starts by sending a command packet from host computer to a PLC and the PLC of the same 10 fetches the command packet by comparing the first byte of the command packet with its own 10. The PLC is programmed to perform a various functions and the function is selected by the content of the command byte, which is the second byte of the command packet. The third byte, which is the last byte, is a checksum byte. The checksum byte is the sum of the first byte and the second byte and is used to detect the communication error. Depending on the content of the command byte, PLC performs the desired function and returns the response packet back to the host computer. The response packet is also a three-byte packet, 10 byte, response byte and checksum byte. For the independent operation of PLC without being controlled by the host computer, variable length RULE data packet is sent to PLC. In case the communication line is broken, the PLC perform the independent operation by referencing the RULE data. The applicable areas are; building automation system, distributed factory automation, measurement of temperature of toxic or dangerous area.

  • PDF

Change in Agricultural Irrigation Water Quality in Mankyeong River (만경강 수계 농업용수의 시기별 수질변화)

  • Lee, Kyeong-Bo;Lee, Deog-Bae;Lee, Sang-Bok;Kim, Jae-Duk
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.6-7
    • /
    • 1999
  • The water quality at Mankyeong River was surveyed 13 sites of main stream for 6 months from April to September in 1995 and 1997. The monthly average value of $NH_4-N$, $SO_4^{2-}$ and $Cl^-$ showed the highest peak in April while that of $NO_3-N$ showed the highest peak in August. The monthly average value of COD showed the highest peak in September at high temperature season. Concentrations of $NH_4-N$ and $SO_4^{2-}$ in Mankyeong River stream exceeded the standard water quality criteria in many sites. The water quality of Mankyeong River stream was not suitable for the irrigation source excepted the sites such as Hari, Gosan stream and Soyang stream. The floodgate of Mokcheon, Yocheon, Jeonju and Samcheon stream were rapidly polluted by the sewage of city, otherwise the Iksan stream was rapidly polluted by the sewage of swine. The sum of ionic concentrations in Mankyeong River stream was the highest at floodgate of Yocheon by influence of the sewage from city and industry. The order of the major anions and cations concentration in Mankyeong River stream were $SO_4^{2-}$ > $Cl^-$ > $NO_3-N$ > $SO_4^{3-}$ and $Na^+$ > $Ca^{2+}$ > $NH_4^+$ > $Mg^{2+}$ > $K^+$, respectively.

  • PDF

Early Development of the Ascidian (Halocynthia hilgendorfi ritteti) (리테르개멍게 (Halocynthia hilgendorfi ritteri)의 초기 발생)

  • CHOI Young Jin;KIM Sam Yun;LEE Chi Hoon;RHO Sum;LEE Young Don
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.2
    • /
    • pp.98-104
    • /
    • 2004
  • Early development and metamorphosis of the ascidian (Halocynthia hilgendorfi ritteri) were investigated from fertilized egg. The samples were collected in the coastal waters of Yongdam, northwest of Jeju Island in November 2002. H. hilgendorfi ritteri was solitary ascidian and produced spheral eggs with egg size ranging from $0.33\pm0.01\;mm.$ On the outer surface of the vitelline coat are attached many follicle cells. At $21.0\pm0.5^{\circ}C$ of water temperature, first cleavage took place in about 1.5 hrs after fertilization, and gastrulation followed in about 12.5 hrs. The formation of tailbud embryos and free swimming larvae were observed 13.3 hrs and 20.5 hrs after fertilization, respectively. The size of newly hatched tadpole larva was 1.30-1.45 mm, the larva swam for 2 hrs to 14 hrs. At 4 hrs after hatching, the palpi were lost and tail absorption began with an abrupt rupture of the anterior end of the notochord. At 17-18 hrs after hatching, tail completely absorption and remained trunk. The coniform adhesive papilla began protrusion at 30 hrs after hatching. The oral and atrial siphon formed at 6-7 days after settlement. At 17-18 days after settlement, metamorphosed the larvae developed into protoascidian of which the external morphology was similar to their adult.

REVIEW: Dynamic force effects on batteries (종설: 동적 부하가 배터리에 미치는 영향)

  • Sunghyun, Jie;Taeksoo, Jung;Seunghoon, Baek;Byeongyong, Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.669-679
    • /
    • 2022
  • Lithium-ion battery has been used for lots of electronic devices. With the popularization of batteries, researchers have focused on batteries' electrochemical performances by environmental conditions, such as temperature, vibration, shock and charging state. Meanwhile, due to very serious global warming, car companies have started using lithium-ion batteries even in cars, replacing internal combustion engines. However, batteries have been developed based on non-moving systems which is totally different from vehicles. In the line of the differences, researchers have tried to reveal relationship between variables from dynamic systems and batteries. In this review, we discuss the comprehensive effect of vibration and shock on batteries. We firstly summarize vibration profiles and effect of normal vibration on batteries. We also sum up effect of shock and penetration on batteries and introduce how ultrasound influences on batteries. Lastly, outlook for the battery design as well as dynamic design of EVs are discussed.

Evaluation of Water Quality Characteristics and Water Quality Improvement Grade Classification of Geumho River Tributaries (금호강 수계 지류하천의 수질 특성 평가 및 수질개선 등급화 방안)

  • Jung, Kang-Young;Ahn, Jung-Min;Kim, KyoSik;Lee, In Jung;Yang, Duk Seok
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.767-787
    • /
    • 2016
  • In this study, we analyzed on-site monitoring data for 15 tributaries in Geumho watersheds for 3 years (2011-2013) in order to sort out priorities on water quality characteristics and improvement. As a result of estimating contribution to contamination of the tributary rivers, Dalseocheon showed the highest load densities, despite the smallest watershed area, with 22.7% $BOD_5$, 30.7% $COD_{Mn}$, 31.3% TOC and 47.6% TP. After conducting PCA (principal component analysis) and FA (factor analysis) to analyze water quality characteristics of the tributary rivers, the first factor was classified as $COD_{Mn}$, TOC, EC, TP and $BOD_5$, the second factor as pH, Chl-a and DO, the third factor as water temperature and TN, and the fourth factor as SS and surface flow. In addition, arithmetical sum of each factor's scores based on grading criteria revealed that Dalseocheon and Namcheon were classified into Group A for their highest scores - 96 and 93, respectively -, and selected as rivers that require water environmental management measures the most. Also, water environmental contamination inspection showed that Palgeocheon had the most number of aquatic factors to be controlled: $BOD_5$, $COD_{Mn}$, SS, TOC, T-P, Chl-a, etc.

Characteristics of NOB Formation in a Coaxial Multi-Air Staged LPG Flame (동축 공기다단 LPG화염의 NOx 생성특성에 관한 연구)

  • Kim, Han-Seok;Ahn, Kook-Young;Kim, Ho-Keun;Yu, Myung-Jong;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.215-226
    • /
    • 2003
  • Experimental and numerical studies have been done to examine the effects of excess air ratio and tertiary air swirl number on the formation characteristics of NOx in a pilot scale combustor adopting a multi-air staged burner. In numerical calculation the mathematical models for turbulence, radiation and nitric oxide chemistry were taken into account. The radiative transfer equation was solved using the discrete ordinates method with the weighted sum of gray gases model. In the NOx chemistry model, the chemical reaction rates for thermal and prompt NOx were statistically averaged using a probability density function. The results were validated by comparison with measurements. For the experiment, a 0.2 MW pilot multi-staged air burner has been designed and fabricated. Using the numerical simulation developed here, a variation of thermal and prompt NOx formation was predicted by changing the excess air ratio and tertiary air swirl number. As the excess air ratio increased up to 1.9, the formation of the total as well as thermal NOx at exit increased while the prompt NOx decreased. The formation of thermal NOx was more affected by concentration of $O_2$ and $N_2$ than gas temperature. When the tertiary air swirl number increased, the formation of the total as well as the prompt NOx slightly decreased.

Intercomparison of Carbonaceous Analytical Results using NIOSH5040, IMPROVE_A, EUSAAR2 Protocols (NIOSH5040, IMPROVE_A, EUSAAR2을 이용한 탄소 분석 결과 비교)

  • Oh, Sea-Ho;Park, Da-Jeong;Cho, Ji-Hye;Han, Young-Ji;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.447-456
    • /
    • 2018
  • Elemental carbon (EC) and organic carbon (OC) thermal/optical methods for the analysis of ambient particulate matter were used to analyze twenty-two $PM_{2.5}$ samples along collected from May 28 to June 20 of 2016 at the Anmyeon measurement site ($36.32^{\circ}N$; $126.19^{\circ}E$). The three laboratory OCEC protocols, which are the National Institute of Occupational Safety and Health (NIOSH5040), the Interagency Monitoring of Protected Visual Environments_A(IMPROVE_A), and European Supersites for Atmospheric Aerosol Research2 (EUSAAR2), were utilized for the aerosol characterization experiment as in intercomparisons between three protocols. There are excellent agreement for total carbon (i.e. sum of EC and OC), but statistically significant differences were observed in the split between the measured EC and OC. IMPROVE_A EC values were always larger than both NIOSH5040 and EUSAAR2 protocols. These methods exhibited significantly different temperature-distributions based on thermogram analysis, which is normalized to total carbon. In this study, a protocol for carbonaceous analysis is suggested for the Korean Peninsula.

The biological and biochemical characteristics of a Vibrio sp., causative agent of intestinal necrosis of flounder larvae (Paralichthys olivaceus) (넙치, Paralichthys olivaceus 자어(仔魚)에서 분리(分離)한 장관백탁증(腸管白濁症)의 원인균(原因菌)인 Vibrio sp.(INFL group)의 생물학적(生物學的) 및 생화학적(生化學的) 특성(特性))

  • Lee, Jung-Baik;Rho, Sum;Song, Choon-Bok
    • Journal of fish pathology
    • /
    • v.8 no.2
    • /
    • pp.99-109
    • /
    • 1995
  • The diseased larvae of the flounder, Paralichthys olivaceus, were sampled several times from a fish hatchery located in Cheju Island between December, 1991 and April, 1992. They turned out to be infected with Vibrio sp. and diagnosed as intestinal necrosis of flounder larvae(INFL) based on morphological, biological, and biochemical examinations. INFL was known to be caused by the live food organism infected with Vibrio sp. The optimal growth conditions of the isolates for temperature, pH, and NaCl concentration were $20\sim30^{\circ}C$, 6~8, and 2~4%, respectively. In the drug sensitivity test, the isolates were sensitive to oxytetracycline, nalidixic acid, kanamycin, and novobiocin, but resistant to ampicillin, erythromycin, spiramycin and sulfa-drug.

  • PDF

A comparison on the heat load of HTS current leads with respect to uniform and non-uniform cross-sectional areas

  • Han, Seunghak;Nam, Seokho;Lee, Jeyull;Song, Seunghyun;Jeon, Haeryong;Baek, Geonwoo;Kang, Hyoungku;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.3
    • /
    • pp.44-48
    • /
    • 2017
  • Current lead is a device that connects the power supply and superconducting magnets. High temperature superconductor (HTS) has lower thermal conductivity and higher current density than normal metal. For these reasons, the heat load can be reduced by replacing the normal metal of the current lead with the HTS. Conventional HTS current lead has same cross-sectional area in the axial direction. However, this is over-designed at the cold-end (4.2 K) in terms of current. The heat load can be reduced by reducing this part because the heat load is proportional to the cross-sectional area. Therefore, in this paper, heat load was calculated from the heat diffusion equation of HTS current leads with uniform and non-uniform cross-sectional areas. The cross-sectional area of the warm-end (65K) is designed considering burnout time when cooling system failure occurs. In cold-end, Joule heat and heat load due to current conduction occurs at the same time, so the cross-sectional area where the sum of the two heat is minimum is obtained. As a result of simulation, current leads for KSTAR TF coils with uniform and non-uniform cross-sectional areas were designed, and it was confirmed that the non-uniform cross-sectional areas could further reduce the heat load.