• Title/Summary/Keyword: subway system

Search Result 859, Processing Time 0.031 seconds

System and method for accurate train stop in manual operation mode (수동운전 모드에서 정위치 정차 방법 및 연동 시스템)

  • Son Young-Jin;Ahn Cheong-Mo;Jeong Dong-Yoon;Park Byoung-No
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1504-1506
    • /
    • 2004
  • The platform screen door(PSD) hasn't been installed yet within the manual operation system, that is, ATS & ATC Signal system. In other countries, it is mostly installed and operated within automatic operation system, that is, ATO. Especially, as a part of the environment friendly system installation, the installation of PSD shall be considered aggressively to improve the air quality in the underground area and to maintain the air-conditioning. Besides the number of suicides in the subway station gets increased these days causing safety hazard, so the installation of PSD is positively reviewed. To install PSD in the manual operation system, it is important to stop the train at the correct position. So we would like to suggest the technical system thereby.

  • PDF

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

Standardization Specification Research for Linear Induction Motor Type Light Rail Vehicle (선형유도모터형 경량전철 표준사양 연구)

  • Hong, Jai-Sung;Ryu, Sang-Whan;Lee, Ahn-Ho;Hwang, Hyeon-Chyeol
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.40-44
    • /
    • 2007
  • Light rail vehicle is optimized vehicle system for complex urban circumstance. LRT systems have many merits such as improve accuracy, speediness and safety. There are many LRT systems such as monorail, tram, automated guideway transit, linear induction motor propulsion and so on. These systems have operated in Japan and other advanced countries. In Korea, local government has many projects to apply the advanced LRT system. But there are no standardized specification, performance test specification, construction specification for monorail system, linear induction motor propulsion system, tram in Korea up to now. So, we need to establish of standardized to economical construction and safety. The linear induction motor system has been usually applied in Japan subway and ART(Advanced Rapid Transit) of Canada. In Korea, the linear induction motor system has been adopted for Yongin LRT and currently under construction. This paper covers the contents and technical base for main items of rolling stock, performance standard, carbody structure, bogie, electronic unit and brake equipment in order to implement linear induction motor LRT system according to local conditions.

  • PDF

An analysis according to the caange in power SCADA systems from the viewpoint of the operator (운영자입장에서 본 전력 SCADA시스템 변화에 따른 분석)

  • Oh, Sung-Hyo;Choi, Sang-Chun;Choi, Si-Haeng
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.407-416
    • /
    • 2008
  • The OCC of Seoul Metro whose operation began in 1974 is in charge of conveying 4,000,000 passengers across 117 subway stations in travel zones of 134.9Km in length. It continues to strive to ensure passenger safety by applying state-of-the-art-technology to each control system without delay. The power control center especially designed to provide power system operations for all stations of Seoul Metro(Line 1 to 4) and the rolling stocks implements preventive safety systems with the real time power system operational information on changes in conditions from the field through the power SCADA system(41 substations, 117 stations, 137 terminal units). This paper reports the differences of each line's power SCADA system(power SCADA systems of Seoul Metro(Line 1 to 4)), the roles and functions of the system, and the system operating characteristics and limits from the standpoint of the operator.

  • PDF

Real-Time Surveillance of People on an Embedded DSP-Platform

  • Qiao, Qifeng;Peng, Yu;Zhang, Dali
    • Journal of Ubiquitous Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.3-8
    • /
    • 2007
  • This paper presents a set of techniques used in a real-time visual surveillance system. The system is implemented on a low-cost embedded DSP platform that is designed to work with stationary video sources. It consists of detection, a tracking and a classification module. The detector uses a statistical method to establish the background model and extract the foreground pixels. These pixels are grouped into blobs which are classified into single person, people in a group and other objects by the dynamic periodicity analysis. The tracking module uses mean shift algorithm to locate the target position. The system aims to control the human density in the surveilled scene and detect what happens abnormally. The major advantage of this system is the real-time capability and it only requires a video stream without other additional sensors. We evaluate the system in the real application, for example monitoring the subway entrance and the building hall, and the results prove the system's superior performance.

  • PDF

Development of a Sliding-Plug Entrance Door System for Urban Electric Transit Unit to Reduce Inside Noise Level (전동차 소음저감을 위한 슬라이딩플러그 출입문 개발)

  • 서승일;임영호;신동국
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.2
    • /
    • pp.112-117
    • /
    • 2002
  • Reduction of noise level in the cabin of urban transit unit is an important issue to enhance the comfortability of passengers. It is made clear that a cause of increased noise level in cabin is the imperfect airtightness of entrance doors. In this study, the sliding-plug door system is developed to reduce the noise level of cabins by securing the airtightness of entrance door. The sliding-plug door system is composed of air-driven engine, swing arms, guide rails, guide rollers and locking devices. It is economical owing to using the previous door engine system. It is also adequate for the platform system of our subway station. It was tested to prove the reliability of system and was applied to standard urban transit unit. The effectiveness of noise reduction in cabin resulting form the sliding-plug door system was confirmed by test results.

A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate (대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량)

  • 박외철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.

A Simulation for the Train Automatic Operation Control System (전동차의 자동운전제어 시스템에 관한 시뮬레이션 기술)

  • 한성호;윤용기;안태기;김원경;조연옥
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.255-261
    • /
    • 1998
  • The train automatic operation control system is an on-board train control system that is widely adopted in modern rapid transit systems. The control system consists of TCMS(Train Control and Monitoring System), ATC(Automatic Train Control), ATO(Automatic Train Operation) and TWC(Train to wayside communication) in the train and wayside facilities. The functions of the system is to regulate train riding comfort, to service limited speed and smoothness during start, acceleration, constant speed travel, and fixed point parking under the corresponding commands. The paper describes the simulation model of the train automatic operation control of subway system, configuration of simulator hardware and software and operational algorithms.

  • PDF

A Numerical Study of Ventilation System Operation for Smoke Control in a Subway Station when a Train under Fire is Approaching (화재열차가 진입하여 정차하는 지하철 역사에서 제연을 위한 환기장치 운전에 대한 수치해석 연구)

  • Lee, Seung-Ho;Hur, Nahm-Keon;Cha, Chul-Hyun;Ryou, Hong-Sun;Kim, Dong-Hyeon;Jang, Yong-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.136-141
    • /
    • 2009
  • The platform screen door(PSD) is installed in the station of the Seoul Metro 9th line for passengers' safety and comfortable environment of the station. The track way exhaust system(TES) is also operated with PSD to exhaust heat released from train. TES can also be used for the purpose of the heat and smoke control in an emergency case of the carriage fire. When the fire is occurred, operation of TES is switched to the smoke exhaust mode form its normal ventilation mode. In the present study, a subway station of Seoul Metro 9th line is modeled, and a 3-D CFD simulation is performed to investigate effectiveness of designed TES in case of fire. A scenario that a train under fire is arriving the station is simulated for several possible operation modes of the TES using moving mesh technique. As a result, temperature and CO concentration distribution in the station is obtained for each operation modes of TES. The effectiveness of TES operation in case of fire is also discussed.

  • PDF

A Study on the Application of the Six Sigma Techniques to Railway Safety (철도안전의 6시그마 기법 적용방안 연구)

  • Song, Bo-Young;Kim, Man-Ung;Moon, Dae-Seop;Lee, Dong-Hun
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.793-799
    • /
    • 2009
  • Using transportations like railway, aviations and roads have been increasing continuously. Traffic accidents have been increasing as well. To prevent or lessen these accidents become a big issue to solve. Therefore, more enforced safety levels are being required to meet. In railway field, continuous efforts of railway safety are being executed to prevent traffic accidents. In present, railway accidents have been decreasing since subway accident happened in Daegu Subway in 2003. However, safety levels in railway field have not yet achieved as much as in advanced countries. Basic concept for enforced safety level in railway system is to prevent or minimize accidents by managing systems like related facilities, management method, organization, education. This is the same concept to minimize error rate in six sigma theory. In this paper, we are to apply six sigma techniques used in manufacturing industry to railway safety and go through ways to make more efficient railway safety system.