• Title/Summary/Keyword: subway system

Search Result 859, Processing Time 0.033 seconds

A Numerical Study on Passenger Evacuation in a Subway Station in Case of Fire Occurrence (화재 발생 지하철 역사에서의 여객 대피 해석에 관한 연구)

  • Kim, Chi-Gyeom;Lee, Sung-Won;Hur, Nahm-Keon;Nam, Seong-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.509-514
    • /
    • 2010
  • A numerical simulation of passenger evacuation in a subway station was performed by coupling the passenger flow analysis and the fire simulation. The algorithm of the passenger flow analysis was based on a DEM (Discrete Element Method) using the potential map of the direction vector for each passenger. This algorithm was improved in the present study as to use finer grid smaller than a passenger in order to resolve detailed geometry of the station and to resolve the behavior of passengers in the bottleneck at the ticket gate considering the collision of passengers to a wall or with other passengers. In the fire simulation, the CO distribution predicted by using CFD was used to take into account the effect of toxic gases on the passengers' mobility. The methodology proposed in the present study could be used in designing safer subway station in case of fire occurrence.

Failure Analysis on the Equipment of PCS common-repeater at the Metropolitan Subway (수도권 지하철내 PCS 공용중계기 장비장애 분석)

  • 신지윤;박덕규
    • The Journal of the Korea Contents Association
    • /
    • v.3 no.2
    • /
    • pp.78-86
    • /
    • 2003
  • The Minisoy of Information and Communication(MIC) requires telecompanys to share base stations in order to prevent the duplicated investment and environmental destruction which would be caused by the indiscreet construction of basestations for enlarging their own service area among telecompanys. This paper discusses' the problems of mobile communication services that have been generated in common-repeater at the Metropolitan subway. These problem include factors of power obstacles, communication equipment and establishment obstacles. The content of this paper is helpful in organizing the basestation sharing of IMT-2000 and the 4th generation mobile system, and provides the basics of a higher quality service for common-service communication.

  • PDF

Mode Choice Behavior Analysis of Commuter Feeder Passengers to Subway System (통근.통학자의 지하철 연계교통수단 선택행태분석)

  • 정헌영;김정주
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.5
    • /
    • pp.69-82
    • /
    • 2000
  • When new subway lines are considered to construct in a large city, there is a need to establish the appropriate transfer systems between subway and other transit modes, so as to increase the use of subway system. In this study, a multi-nominal logit model is developed to analyze the travel characteristics and the mode choice of subway Passengers transferring to and from the buses, minibuses and taxi. These passengers represent a large Portion of transit Passengers in Pusan city It shows that the explanatory variables that affect Passengers\` mode choice are in order of OVIT(Out-of-Vehicle Travel Time), IVTT(In-Vehicle Travel Time), transit fare,. income, gender, and age in modeling. In particular, OVTT is shown to have more significant impact on the mode choice than IYTT due to the fact that transfer trip is involved only in a short distance. Variables associated with the travel costs, however, do have an insignificant impact on the mode choice. It shows that it would be a better Policy to improve the quality of transit service using additional financial resource by increasing transit fare rather than by reducing the fare to increase travel demand. It also shows that value of travel time of OVTT is remarkably higher than that of IVTT and value of travel time of taxi Passengers is much higher than that of minibus Passengers .

  • PDF

A study on the evaluation of fire safety according to the ventilation mode in a train fire at the subway platform (지하철 승강장에서 열차 화재시 제연모드에 따른 화재 안전성 평가 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.293-310
    • /
    • 2020
  • The purpose of this study is to present the most effective smoke exhaust mode by comparing the quantitatively evaluated risks according to the smoke exhaust mode when a train fire occurs in a subway platform. Therefore, applying the typical subway platform as a model, train fire scenarios are developed with the evacuation start time and location of the fire train for each exhaust mode. The fire accident rates (F) are calculated and the number of fatalities (N) was quantitatively estimated by fire analysis and evacuation analysis for each scenario. In addition, the F/N curve compared with the social risk assessment criteria and the following conclusions were obtained. In the event of a train fire at the subway station platform, the evacuation must start up within 600 s in maximum to ensure the evacuees' safety. To secure evacuation safety, it is advantageous to operate the HVAC system of the platform in the air-supply mode at station without TVF. Comparing the F/N curve for each exhaust mode with the social risk criteria, it turned out that the risk significantly exceeds the social risk criteria in case of no mechanical ventilation. As a result, this paper shows that the ventilation mode in which TVF are exhausted and HVAC system is operated in the pressurized mode are the most effective smoke exhaust mode for ensuring evacuation safety.

Groundwater Investigation of the Cheonggyecheon Watershed Area

  • Choi, Doo-Hyung;Yang, Jea-Ha;Jun, Sung-Chun;Lee, Kang-Keun;Kim, Yoon-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.323-327
    • /
    • 2004
  • The groundwater system of the Cheonggyecheon watershed is very complicated because it is influenced by many factors such as pumping out, groundwater leakages into subway stations, civil use of groundwater, and leaking water from water supply and sewage lines. So the characterization and evaluation of tile groundwater flow and contaminant transport in the Cheonggyecheon water system is quite a difficult task. The purpose of this study is to analyze of the influence to the 'groundwater' below the Cheonggyecheon watershed by the 'surface water' on the Cheonggyecheon stream after the restoration. We have so far collected groundwater quality data, hydrogeologic aquifer parameters, and tile amount of leakages into subway stations and its influence on the groundwater system of the Cheonggyecheon. Results show that groundwater level was influenced by the direction and depth of a 녀bway station. This study will continue to monitor groundwater quality, a water level fluctuation relation between rainfall and groundwater recharge for further investigation of the groundwater flow system in Cheonggyecheon.

  • PDF

A study on Fairing System for Traveling Noise Reduction in Urban Subway (도시철도 운행소음 저감용 훼어링시스템 연구)

  • Choi, Sang-Chun;Jang, Won-Rak;Ho, Kyoung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.659-666
    • /
    • 2009
  • As the density and height of the buildings nearby subway lines get higher, the unprecedented residents' appeals for noise are on the rise. Furthermore, in accordance with the revision of enforcement regulations on the Noise and Vibration Control Act, the night time noise standards have been reinforced by 5dB effective on January 1st 2010 and the appropriate measures shall be taken accordingly. For the settlement of the public grievances against noise and vibration generated on tracks in at-grade and elevated section, the installation of continuously-welded-rail, rail lubrication system, improved fastening system and higher noise barrier is currently executed. Nevertheless, the noise and vibration levels in some areas are still exceeding the limits required in the regulation. Among the measures, an installation of higher noise barrier or noise tunnel seems to be the most effective way; however, it has limitations owing to the structural stability of existing elevated structures. The paper in consideration of the local conditions and foreign practices discusses the installation of fairing system under the train body as an noise insulation panel in order to reduce the rolling noise and under-carriage noise. Based on the result of this study, a performance verification test during actual train operation is in progress for further study.

  • PDF

An Empirical Study on the Relationship between Subway Trips and Characteristics of Subway Catchment Area. (역세권 특성이 지하철 이용수요에 미치는 영향분석)

  • Jo, Hyun-Woo;Lee, Seok-Hwan;Shin, Kang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.5191-5198
    • /
    • 2010
  • Although numerous studies have analyzed the relationship between subway travel demand (STD) and various characteristics of subway catchment area (SCA), a few studies examined the relationship between STD and the structure of pedestrian networks within each SCA. Hence, this study evaluates the structure of pedestrian networks within 79 SCAs in the city of Busan using Space syntax and investigates the relationship between STD and several characteristics of SCA including the spatial structure of pedestrian network. The analysis results show that the spatial integration of pedestrian networks within the SCAs, which represents the magnitudes of walking accessibility to subway station, is positively associated with STD among the three spatial indexes such as integration, connectivity, and intelligibility. In addition, the results show that STD significantly increases as the number of travel gathering facilities and the average floor area ratio within the SCAs increase. This study ultimately corroborates that designing the grid pedestrian network and assigning the travel gathering facilities to the compact buildings within SCAs are needed to ameliorate the spatial structure of SCA in the city of Busan as transit-oriented development system.

A Study on Environmental Design Treatments of Subway Stations in Terms of Visual Cues for Place Indication - Focused on the Cases of Seoul, Tokyo and Taipei - (장소지시단서로서의 지하철역 환경디자인 기법에 관한 연구 -서울, 동경, 타이페이 사례를 중심으로-)

  • Park, Hey-Kyung
    • Archives of design research
    • /
    • v.19 no.5 s.67
    • /
    • pp.351-362
    • /
    • 2006
  • Currently, finding one's way in the underground spaces associated with subway stations in large cities is becoming a serious problem, and an environment that facilitates wayfinding is becoming more important. This study investigated interior treatments that function as visual cues in the subway stations of Seoul, Tokyo, and Taipei in order to develop design guidelines that would improve the place-cognition environment. A theoretical study has shown that there are three categories of visual cue for place cognition: marked trails, regional differentiation, and landmarks. The case study showed that marked trails involve treatments like vertical markers, confrontational positioning, and subway color codes. Regional differentiation involves patterns on the floors and walls, and accent colors on the walls and columns. Landmarks include treatments such as super graphics, symbolic features, artistic decoration and special lights. In the cases of Seoul, marked trails and regional differentiation were predominant. In addition, the Olympic symbol 'Hodori' and the ancient Korean character "Hunminjungeum" were used as landmarks. In the cases of Tokyo, regional differentiation predominated over marked trails because of the complexity of the spatial structure and subway line connection system. In the cases of Taipei, simple, unified images predominated, and there was minimal dependence on marked trails and landmarks. The need for regional differentiation was weak, because the stations studied have open structures that guarantee an open field of view. The results of this research could be used as design guidelines, after further experimental verification, that would help to improve the public environment in terms of wayfinding.

  • PDF

Smoke Control in a Subway Station Platform with Screen Doors - Based on Busan Subway Line 3 - (스크린도어 설치에 따른 지하승강장 제연의 문제점과 대책 - 부산 지하철 3호선을 중심으로 -)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.50-54
    • /
    • 2006
  • A fire in a subway station platform, completely isolated by screen doors, was numerically simulated to investigate problems in smoke control and find their countermeasures. A part of the platform, $40m{\times}5m$ floor and 3 m high, and a fire of 1 MW were considered, and the smoke extraction system was assumed to start operation at the onset of the fire. For three different values of the exhaust air flow rate, 0.1, 2, and $4m^3/min-m^2$, the distributions of temperature, concentrations of soot and carbon monoxide, and those of visibility were compared. The time-variations of the number of randomly distributed particles in the space were also investigated for the air flow rates to see the efficiency in smoke control. It was shown that smoke control takes time by lack of air supply. It was also confirmed that air supply from the railway to the platform at emergency is needed so that smoke is able to be controlled efficiently, and that opening the doors at the both ends of the platform is desirable until the fire is completely extinguished.

A study of comparative of evacuation time by platform type according to the propagation speed of smoke in subway platform fire (지하철 승강장 화재시 연기의 전파속도에 따른 승강장 형태별 피난시간 비교·분석 연구)

  • Kim, Jin-Su;Rie, Dong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.577-588
    • /
    • 2017
  • There are many constraints, both economically and ethically that experimenting human evacuation behavior in situations such as fire. Therefore, the evacuation behavior is simulated based on the existing studies. In recent years, the foundation has been established as computer performance advances, models closer to reality can be studied. In this study, the evacuation time in the subway platform was analyzed from modeling human behavior and smoke propagation in a fire. The evacuation efficiency was also examined by dividing the shape of the subway station platform by the stair position and comparing the evacuation times for each platform. As a result, it was found that the side platform was longer than the island platform by 36.82% more time to evacuation. The shape of the stairs is most advantageous in terms of evacuation form side type platform was 210 seconds and island type platform was 186 seconds, when a fire occurs in the center of the platform. And most favorable in location of evacuation stairs were located at 2/5 point and 4/5 from depending on the step location.