• Title/Summary/Keyword: subway

Search Result 2,109, Processing Time 0.024 seconds

Recommended Practice for Lighting Load Density by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Subway Stations (회귀분석이론을 이용한 지하철 역사의 조명부하밀도 분석)

  • Jung, Hyeon-Ki;Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.254-259
    • /
    • 2006
  • It is increased electrical energy consumption with the development of intelligence society in the subway station and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design load density in subway stations, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 34 subway stations and 10 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, maximum and thus it was carried linear and nonlinear regression analysis.

  • PDF

Integrated Ground-Underground Spatial Network for Urban Spatial Analysis (도시 공간분석을 위한 지상·지하 공간 네트워크)

  • Piao, Gensong;Choi, Jaepil
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.4
    • /
    • pp.69-76
    • /
    • 2018
  • The purpose of this study is to propose and verify a spatial network construction method that integrated roads and subway lines to improve the predictability of the urban spatial analysis model. The existing axial map for urban spatial analysis did not reflect the subway line that serves as an important moving space in modern cities. To improve this axial map, proposed a Ground-Underground Spatial Network by integrating the underground spatial network with the axial map. As a result of the integration analysis, the Ground-Underground Spatial Network(GUSN) were similar to the movement frequency. Correlation of GUSN was 0.723, which showed higher explanatory power than correlation coefficient of 0.575 in axial map. The result of this study is expected to be a theoretical basis for constructing spatial network in urban space analysis with subway.

A Convergence Exploration to Restrict Extension of OOH Advertising as Materialization of Borrowed City Phenomenon in Korea (한국의 빌린도시 현상의 유물화로서 옥외광고 확장을 제한하는 융복합적 탐색)

  • Moon, Yun-Su
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.9-20
    • /
    • 2015
  • To derive a check list of a borrowed city phenomenon, this discussion, through two cities subway OOH advertising in door, compared for convergence by segment analysis. First, discussions considered to be close to the topic of this discussion were arranged and summarized. Seoul and London were selected, and both sides of subway train doors in two cities selected, their states pictured and the images analyzed. As a result of comparison, in case of Seoul subway, the boundary between public information and commercial information(outdoor advertising) was very vague, so the borrowed city phenomenon was very generally analyzed. However, In case of London subway, its result was very contrary to that of Seoul. Eventually, Subway train doors of Seoul city as a borrowed city extracted check points of height, size, color, interval, space and permanency. Therefore in order to study serious discussion this contribution is necessity to limit thoughtless OOH advertising by these checklists in Korean cities.

Numerical Study on the Improvement Heat and Smoke Control System in Old Subway Station on Train Fire (수치해석을 통한 노후 지하철 역사 내 열차 화재 시 제연모드 개선에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.88-96
    • /
    • 2017
  • The subway can transport a lot of people at a certain route at once, and the railway and the platform are underground, so it is advantageous to use the ground space efficiently. But If a fire occurs in a subway that is used by an unspecified number of people, such as the Daegu Subway Fire Disaster, many casualties can occur. As a result of the previous research, it was confirmed that the performance of the ventilation system of the old subway platform was remarkably degraded. Therefore, in this study, based on the experimental results of the previous research, we confirmed the flow of the hot and CO flows according to the ventilation mode in the case of fire by three - dimensional numerical analysis. As a result, it was found that the old ventilation system could not maintain the hot air temperature below the reference value for 4 minutes based on the evacuation time of the platform, and when the ventilation performance was enhanced by adding Oversized Exhaust Ports at the upper part of the platform, And the temperature of the heat flow can be maintained.

Evaluation of Exposure Characteristics of Fine Dusts by Subway Lines (지하철역사의 호선별로 미세먼지의 노출특성에 대한 평가)

  • Hwang, Sung Ho;Kim, Jeong Oh
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.1
    • /
    • pp.71-76
    • /
    • 2017
  • Objectives: This study aimed to assess the environmental factors that affect particulate matters (PM10) and to compare with outdoor PM10 concentrations in an underground subway stations. Methods: The PM10 level was determined from May 2013 to September 2013 in the Seoul subway stations in four lines. PM mini-vol portable sampler sampler was used to collect PM10 for 6 hrs. Arithmetic means of PM10 concentrations with standard deviation (SD) were calculated. Paired t-test was used to compare the differences between indoor PM10 and outdoor PM10 concentrations with correlation analysis which was used to identify the association between indoor PM10 concentrations and environmental factors. Results: There were no different PM10 concentrations significantly between line 1, 2, 3 and 4 in an underground subway stations. Passenger number was positively associated with PM10 concentration while construction year was negatively associated with PM10 concentrations. Indoor PM10 concentrations were significantly higher than those in outdoor PM10 concentrations. PM10 concentrations were higher in the stations which were constructed before 1990s rather than the stations constructed after 1990s. Conclusion: PM10 levels in the underground subway stations varied greatly depending on the construction year. Therefore, it might need to be more careful management to the stations which constructed in before 1990s.

Smoke Control According to the Ventilation Capacity in Subway Tunnel Fire: I. FDS Simulation (지하철 터널 화재시 환기시설의 용량에 따른 제연효과 I. FDS 시뮬레이션)

  • Park, Kyung-Jun;Lee, Ki-Jun;Hadi, Bettar El;Lee, Jai-Hyo;Shin, Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.31-38
    • /
    • 2011
  • In this study, we investigate simulation studies to confirm the removal of smoke through ventilation when the subway car is on fire and stopped in an underground subway tunnel, by using Fire Dynamics Simulator (FDS) which is being upgraded by NIST. The structure of subway tunnel and train for simulation modeling are based actual data from Seoul metropolitan subway. The main purpose of this study is to assure the removal efficiency of the ventilation when changing the ventilation capacity between 2.0 m/s and 3.0 m/s. The results of the study shows that carbon monoxide (CO) and carbon dioxide ($CO_2$) are reduced by about 35% as the ventilation capacity is increased by 0.5 m/s. This study also performs the grid sensitivity verification of FDS for improved accuracy of the results. To find the effective size of the grid, three cases are simulated and the results are compared.

Development of Underground Facilities Management System on Subway Construction (지하철공사를 위한 지하매설물관리시스템 개발)

  • 강인준;장용구;정영미
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.75-80
    • /
    • 1997
  • In other to construct a subway, we have to consider the position of the subway and acquisition of a topography, profile-map, cross-map, underground facilities map. All information of underground is demanded accurate location in other to prevent of accident of underground in subway construction. We must think about water lines, sewer lines, electronic lines, telephone lines, all urban gas-line because these are needed construction the subway. And attributes of underground facilities recorded on topography are characteristics. length, width. number, position, and depth of the lines. We have to record these attributes because these are very important to design map on subway construction. If we develop GIS (Geographic Information System) to use the exact in-formation of the underground facilities, we can be management safely and prevent very dangerous accident as fast as possible. In this study, attribute informations are linked geographic informations about underground facilities and we can develop Underground Facilities Management System(UFMS) to analysis dangerous region through dangerous degreed and predict accident range with these informations.

  • PDF

Characterization of Aerosols Collected at a Subway Station Platform Using Low-Z Particle Electron Probe X-ray Microanalysis (Low-Z particle EPMA 단일입자 분석법을 이용한 지하철 승강장에서 미세입자 특성 분석)

  • Hwang HeeJin;Oh MiJung;Kang Sun-ei;Kim HyeKyeong;Ro Chul-Un
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.639-647
    • /
    • 2005
  • A single particle analytical technique, named low-Z particle electron probe X-ray microanalysis (EPMA), was applied to characterize samples collected at a subway station and ambient samples in Seoul. According to their chemical composition, many distinctive particle types were identified. For samples collected at the subway station platform, the major chemical species are carbon-rich, organic, aluminosilicates (AlSi), AlSi/C, AlSi/$CaCO_{3},\;CaCO_{3},\;SiO_{2},\;and\;Fe_{2}O_{3}$. For outdoor samples, carbon-rich, organic, AlSi, $CaCO_{3},\;SiO_{2},\;NaNO_{3},\;(Na,Mg)NO_{3},\;Na(CO_{3},NO_{3},SO_{4}),\;and\;(NH_{4})_2SO_4$, are abundantly encountered. Samples collected at the subway station show very high contents of $Fe_{2}O_{3}$, both in coarse and fine fractions, which come from brake block, subway train wheel, electric contact materials, etc. It is demonstrated that the single-particle characterization using this low-Z particle EPMA technique provided detailed information on various types of chemical species in indoor and outdoor samples.

Investigation and Evaluation of Noise Level of the Busan Subway (부산 지하철 소음도 조사 및 평가)

  • Lee, Chang-Myung;Jung, Jin-Guk;Jung, Jin-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.243-250
    • /
    • 2011
  • Noise levels of the three subway lines of Busan city have been investigated. Averaged cabin noise of the train has been measured during the train trip for each station. It has been measured with separation of day time (9:00~18:00) and night time (18:00~22:00) measurements but there was no big difference on the measured data. Repeating for the measured data has been confirmed with twice measurements in May and June 2010. Several noise effects to the subway noise levels of Busan are explained. Those are screen door effect, rail road surface condition, subway train type and curvature of railway. Among three subway lines of Busan city, the line 2 is relatively noisy and its reasons are studied. It has been shown that the screen door effect is 10 dB(A) and S shape of sharp curve contributes in high noise level.