• Title/Summary/Keyword: subtractive

Search Result 289, Processing Time 0.023 seconds

Comparison of prosthetic models produced by traditional and additive manufacturing methods

  • Park, Jin-Young;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Jae-Hong;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.294-302
    • /
    • 2015
  • PURPOSE. The purpose of this study was to verify the clinical-feasibility of additive manufacturing by comparing the accuracy of four different manufacturing methods for metal coping: the conventional lost wax technique (CLWT); subtractive methods with wax blank milling (WBM); and two additive methods, multi jet modeling (MJM), and micro-stereolithography (Micro-SLA). MATERIALS AND METHODS. Thirty study models were created using an acrylic model with the maxillary upper right canine, first premolar, and first molar teeth. Based on the scan files from a non-contact blue light scanner (Identica; Medit Co. Ltd., Seoul, Korea), thirty cores were produced using the WBM, MJM, and Micro-SLA methods, respectively, and another thirty frameworks were produced using the CLWT method. To measure the marginal and internal gap, the silicone replica method was adopted, and the silicone images obtained were evaluated using a digital microscope (KH-7700; Hirox, Tokyo, Japan) at 140X magnification. Analyses were performed using two-way analysis of variance (ANOVA) and Tukey post hoc test (${\alpha}=.05$). RESULTS. The mean marginal gaps and internal gaps showed significant differences according to tooth type (P<.001 and P<.001, respectively) and manufacturing method (P<.037 and P<.001, respectively). Micro-SLA did not show any significant difference from CLWT regarding mean marginal gap compared to the WBM and MJM methods. CONCLUSION. The mean values of gaps resulting from the four different manufacturing methods were within a clinically allowable range, and, thus, the clinical use of additive manufacturing methods is acceptable as an alternative to the traditional lost wax-technique and subtractive manufacturing.

Molecular Cloning and Characterization of Wound-inducible Beta-amyrin Synthase from Soybean (콩으로부터 상처 유도 beta-amyrin synthase 유전자의 동정 및 발현분석)

  • Park, Seong-Whan;Lee, Jai-Heon
    • Journal of Plant Biotechnology
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • Suppression subtractive hybridization (SSH) was used to isolate wound-induced cDNAs from wounded soybean. One of wound-induced cDNA, gmwi33 showed high homology with genes encoding $\beta$-amyrin synthase. The full length cDNA of gmwi33, designated GmAMS1, is 2416 bp long and contains an open reading frame consisted of 739 amino acids. GmAMS1 protein showed 89% identity with licorice GgbAS1 and 86% identity with pea OSCPSY. In 5 day-old, dark-grown seedlings, the expression of GmAMS1 was most strongly induced by light and weakly induced by methyl jasmonate and by low temperature. However, GmAMS1 was not induced by elicitor or UV-B treatment. Such expression pattern might be closely related with the oxygen-radical scavenging activity of soyasaponin.

Monthly Dam Inflow Forecasts by Using Weather Forecasting Information (기상예보정보를 활용한 월 댐유입량 예측)

  • Jeong, Dae-Myoung;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.6
    • /
    • pp.449-460
    • /
    • 2004
  • The purpose of this study is to test the applicability of neuro-fuzzy system for monthly dam inflow forecasts by using weather forecasting information. The neuro-fuzzy algorithm adopted in this study is the ANFIS(Adaptive neuro-fuzzy Inference System) in which neural network theory is combined with fuzzy theory. The ANFIS model can experience the difficulties in selection of a control rule by a space partition because the number of control value increases rapidly as the number of fuzzy variable increases. In an effort to overcome this drawback, this study used the subtractive clustering which is one of fuzzy clustering methods. Also, this study proposed a method for converting qualitative weather forecasting information to quantitative one. ANFIS for monthly dam inflow forecasts was tested in cases of with or without weather forecasting information. It can be seen that the model performances obtained from the use of past observed data and future weather forecasting information are much better than those from past observed data only.

Current Limiting Characteristics of Flux-Lock Type High-TC Superconducting Fault Current Limiter According to Fault Angles (사고각에 따른 자속구속형 전류제한기의 전류제한특성)

  • Park, Hyoung-Min;Lim, Sung-Hun;Cho, Yong-Sun;Park, Chung-Ryul;Han, Byoung-Sung;Choi, Hyo-Sang;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.12-14
    • /
    • 2004
  • We investigated current limiting characteristics of the flux-lock type high-Tc superconcting fault current limiter(HTSC-FCL) according to fault angles. The Flux-lock type HTSC-FCL consists of primary and the secondary copper coils that are wound in parallel each other through the iron core and YBCO thin flim. In this paper, the current limiting characteristics of the flux-lock type HTSC-FCL according to fault angles in case of the subtractive and additive polarity windings were compared and analyzed. From the results, the flux-lock type HTSC-FCL could limit more quickly fault current as the fault angles increased irrespective of the fault angles. On the other hand, the initial power burden of HTSC element after a fault happened increased as the fault angles increased. In addition, it was confirmed that the resistance of flux-lock type HTSC-FCL in case of subtractive polarity winding was more increased than that of additive polarity winding and that the peak current of fault current in case of subtractive polarity winding was larger than that of the additive polarity winding case.

  • PDF

Operational Characteristics in integrated Three-Phase a Flux-Lock type SFCL according to Fault Conditions (3상 일체화된 자속구속형 전류제한기의 동작특성)

  • Lee, Na-Young;Choi, Hyo-Sang;Jeong, Soo-Bok;Lee, Sang-Il;Nam, Gueng-Hyun;Lim, Sung-Hun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.467-470
    • /
    • 2006
  • Superconducting fault current(SFCLs) are expected to improve not only reliability but also stability of real power systems. The analysis on the single line-to-ground fault current of the integrated three phase flux-lock type SFCL, which consists of three flux-lock reactor wound on an iron core in each single phase and three YBCO thin films, was investigated in current limiting operating characteristics. We compared additive polarity winding with the subtractive one in the flux lock reactor. Its turns ratio each phase between the primary and the secondary coils is 63:42. When a single line-to-ground fault occurred in any phase, the peak value of line current in the fault phase of the additive polarity winding increased up to 31.44[A] during first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to 81.77[A] under the same conditions. This is because the current flow between the primary and the secondary windings becomes to be additive or subtractive in each winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to ground fault.

  • PDF

Subtractive versus additive indirect manufacturing techniques of digitally designed partial dentures

  • Snosi, Ahmed Mamdouh;Lotfy, Shaimaa Mohamed;Thabet, Yasmine Galaleldin;Sabet, Marwa Ezzat;Rizk, Fardos Nabil
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.327-332
    • /
    • 2021
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of digitally designed removable partial denture (RPD) frameworks, constructed by additive and subtractive methods castable resin patterns, using comparative 3D analysis. MATERIALS AND METHODS. A Kennedy class III mod. 1 educational maxillary model was used in this study. The cast was scanned after modification, and a removable partial denture framework was digitally designed. Twelve frameworks were constructed. Two groups were defined: Group A: six frameworks were milled with castable resin, then casted by the lost wax technique into Co-Cr frameworks; Group B: six frameworks were printed with castable resin, then casted by the lost wax technique into Co-Cr frameworks. Comparative 3D analysis was used to measure the accuracy of the fabricated frameworks using Geomagic Control X software. Student's t-test was used for comparing data. P value ≤ .05 was considered statistically significant. RESULTS. Regarding the accuracy of the occlusal rests, group A (milled) (0.1417 ± 0.0224) showed significantly higher accuracy than group B (printed) (0.02347 ± 0.0221). The same results were found regarding the 3D comparison of the overall accuracy, in which group A (0.1501 ± 0.0205) was significantly more accurate than group B (0.179 ± 0.0137). CONCLUSION. In indirect fabrication techniques, subtractive manufacturing yields more accurate RPDs than additive manufacturing.

Color evaluation by thickness of interim restorative resin produced by digital light processing 3D printer (디지털 광학기술인 3D 프린터로 제작된 임시수복용 레진의 두께별 색 평가)

  • Kang, Wol;Kim, Won-Gi
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.77-83
    • /
    • 2021
  • Purpose: The purpose of this in vitro study was to measure and compare the thickness-dependent color dimensions of digital light processing (DLP) three-dimensional (3D) printer and conventional interim restorative resin. Methods: Specimens (N=60) were fabricated using either subtractive manufacturing (S group) or DLP 3D printing (D group) material. All milled and 3D-printed specimens were allocated into three different groups (n=10) according to different thicknesses as follows: 1.0, 1.5, and 2.0 mm. Color measurements in the CIELab coordinates were made using a spectrophotometer under room light conditions (1,003 lux). The color differences (𝚫E*) between the specimen and control target data were calculated. Data were analyzed using the oneway analysis of variance (ANOVA). Post hoc comparisons were conducted using Tukey's honestly significant difference method (α=0.05 for all tests). Results: The 𝚫L*, 𝚫a*, 𝚫b*, and 𝚫E* values of interim restorative resin produced by DLP 3D printing were obtained in terms of the specimen's thickness increased compared with the increases by subtractive manufacturing. When the thickness was similar, the color difference between subtractive manufacturing and DLP 3D printing was ≥5.5, which is a value required by the dentist for remanufacturing. Conclusion: Color was influenced by the thickness of the interim restorative resin produced by DLP 3D printing.

Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: a comparative analysis between subtractive and additive manufacturing

  • Kim, Yong-Kyu;Han, Jung-Suk;Yoon, Hyung-In
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.122-132
    • /
    • 2022
  • PURPOSE. This in-vitro analysis aimed to compare the intaglio trueness, the antagonist's wear volume loss, and fracture load of various single-unit zirconia prostheses fabricated by different manufacturing techniques. MATERIALS AND METHODS. Zirconia crowns were prepared into four different groups (n = 14 per group) according to the manufacturing techniques and generations of the materials. The intaglio surface trueness (root-mean-square estimates, RMS) of the crown was measured at the marginal, axial, occlusal, and inner surface areas. Half of the specimens were artificially aged in the chewing simulator with 120,000 cycles, and the antagonist's volume loss after aging was calculated. The fracture load for each crown group was measured before and after hydrothermal aging. The intaglio trueness was evaluated with Welch's ANOVA and the antagonist's volume loss was assessed by the Kruskal-Wallis tests. The effects of manufacturing and aging on the fracture resistance of the tested zirconia crowns were determined by two-way ANOVA. RESULTS. The trueness analysis of the crown intaglio surfaces showed surface deviation (RMS) within 50 ㎛, regardless of the manufacturing methods (P = .053). After simulated mastication, no significant differences in the volume loss of the antagonists were observed among the zirconia groups (P = .946). The manufacturing methods and simulated chewing had statistically significant effects on the fracture resistance (P < .001). CONCLUSION. The intaglio surface trueness, fracture resistance, and antagonist's wear volume of the additively manufactured 3Y-TZP crown were clinically acceptable, as compared with those of the 4Y- or 5Y-PSZ crowns produced by subtractive milling.

A Generalized Subtractive Algorithm for Subset Sum Problem (부분집합 합 문제의 일반화된 감산 알고리즘)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.9-14
    • /
    • 2022
  • This paper presents a subset sum problem (SSP) algorithm which takes the time complexity of O(nlogn). The SSP can be classified into either super-increasing sequence or random sequence depending on the element of Set S. Additive algorithm that runs in O(nlogn) has already been proposed to and utilized for the super-increasing sequence SSP, but exhaustive Brute-Force method with time complexity of O(n2n) remains as the only viable algorithm for the random sequence SSP, which is thus considered NP-complete. The proposed subtractive algorithm basically selects a subset S comprised of values lower than target value t, then sets the subset sum less the target value as the Residual r, only to remove from S the maximum value among those lower than t. When tested on various super-increasing and random sequence SSPs, the algorithm has obtained optimal solutions running less than the cardinality of S. It can therefore be used as a general algorithm for the SSP.

Marginal and internal discrepancy of 3-unit fixed dental prostheses fabricated by subtractive and additive manufacturing (절삭 및 적층 가공법으로 제작된 3본 고정성 국소의치의 변연 및 내면 적합도에 관한 연구)

  • Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.7-13
    • /
    • 2020
  • Purpose: This study was to evaluate marginal and internal discrepancy of 3-unit fixed dental prostheses (FDP) fabricated by subtractive manufacturing and additive manufacturing. Materials and methods: 3-unit bridge abutments without the maxillary left second premolar were prepared (reference model) and the reference model scan data was obtained using an intraoral scanner. 3-unit fixed dental prostheses were fabricated in the following three ways: Milled 3-unit FDP (MIL), digital light processing (DLP) 3D printed 3-unit FDP (D3P), stereolithography apparatus (SLA) 3D printed 3-unit FDP (S3P). To evaluate the marginal/internal discrepancy and precision of the prosthesis, scan data were superimposed by the triple-scan protocol and the combinations calculator, respectively. Quantitative and qualitative analysis was performed using root mean square (RMS) value and color difference map in 3D analysis program (Geomagic control X). Statistical analysis was performed using the Kruskal-Wallis test (α=.05), MannWhitney U test and Bonferroni correction (α=.05/3=.017). Results: The marginal discrepancy of S3P group was superior to MIL and D3P groups, and MIL and D3P groups were similar. The D3P and S3P groups showed better internal discrepancy than the MIL group, and there was no significant difference between the D3P and S3P groups. The precision was excellent in the order of MIL, S3P, and D3P groups. Conclusion: Within the limitation of this study, the 3-unit fixed dental prostheses fabricated by additive manufacturing showed better marginal and internal discrepancy than the those of fabricated by subtractive manufacturing, but the precision was poor.