• Title/Summary/Keyword: subtraction technique

Search Result 150, Processing Time 0.024 seconds

Channel Compensation technique using silence cepstral mean subtraction (묵음 구간의 평균 켑스트럼 차감법을 이용한 채널 보상 기법)

  • Woo, Seung-Ok;Yun, Young-Sun
    • Proceedings of the KSPS conference
    • /
    • 2005.04a
    • /
    • pp.49-52
    • /
    • 2005
  • Cepstral Mean Subtraction (CMS) makes effectively compensation for a channel distortion, but there are some shortcomings such as distortions of feature parameters, waiting for the whole speech sentence. By assuming that the silence parts have the channel characteristics, we consider the channel normalization using subtraction of cepstral means which are only obtained in the silence areas. If the considered techniques are successfully used for the channel compensation, the proposed method can be used for real time processing environments or time important areas. In the experiment result, however, the performance of our method is not good as CMS technique. From the analysis of the results, we found potentiality of the proposed method and will try to find the technique reducing the gap between CMS and ours method.

  • PDF

The efficiency of subtraction technique in a nonequilibrium molecular dynamics simulation of a simple liquid shear flow (단순액체의 층밀리기 흐름에 대한 비평형 분자동력학 계산에서 공제방법의 효과)

  • 안성청
    • Journal of the Korea Society for Simulation
    • /
    • v.6 no.1
    • /
    • pp.53-60
    • /
    • 1997
  • Results from a nonequilibrium molecular dynamics (NEMD) simulation are presented for an argon liquid subject to a shear flow. The segmented molecular dynamics method and the subtraction technique used in NEMD program to reduce the thermal fluctuation noise in data are studied with different shear rates. The standard deviation in the shear stress reduced from 0.030 to 0.004 by the segmented molecular dynamics method for 50 repeated segments. On the other hand, the standard deviation of the data remained the same when the subtraction technique was applied, where as the results of shear stress by constant value in a random way.

  • PDF

THE STUDY OF THE INTERPRETATION OF THE TMJ RADIOGRAPHY USING SUBTRACTION TECHNIQUE (Subtraction법을 이용한 악관절 X-선사진 판독에 관한 연구)

  • Na Choon-Wha;Yoo Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.175-181
    • /
    • 1987
  • The purpose of this study is to know the value of the photographic subtraction technic in the transcranial oblique lateral projection of the TMJ. The author examined the transcranial oblique lateral projection radiographs which comprise 50 cases of 32 persons, compared the transcranial oblique lateral projection films and those subtraction films. The following results were obtained. 1) The condyle at closed jaw position had showed a reversed tone image, but the condyle at the opening position had showed a re-reversed ordinary image. Both condyles had showed one subtraction film because radiographic interpretation of TMJ was easy. 2) On 50 cases of subtraction films, 46 cases had showed same radiographic images compared with trascranial oblique lateral projection films. Four cases (3 cases of erosion, 1 cases of sclerosis) had showed additional changes of images so that capability of interpretation was improved.

  • PDF

Speech Enhancement using Spectral Subtraction and Two Channel Beamfomer (Spectral Subtraction과 Two Channel Beamfomer를 이용한 음성 강조 기법)

  • 김학윤
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.38-44
    • /
    • 1999
  • In this paper, a new spectral subtraction technique with two microphone inputs is proposed. In conventional spectral subtraction using a single microphone, the averaged noise spectrum is subtracted from the observed short-time input spectrum. This results in reduction of mean value of noise spectrum only, the component varying around the mean value remaining intact. In the method proposed in this paper, the short-time noise spectrum excluding the speech component is estimated by introducing the blocking matrix used in Griffiths-Jim-type adaptive beamformer with two microphone inputs, combined with the spectral compensation technique. A simulation was conducted to verify the effectiveness of the method.

  • PDF

Noise-Robust Speech Recognition Using Histogram-Based Over-estimation Technique (히스토그램 기반의 과추정 방식을 이용한 잡음에 강인한 음성인식)

  • 권영욱;김형순
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.53-61
    • /
    • 2000
  • In the speech recognition under the noisy environments, reducing the mismatch introduced between training and testing environments is an important issue. Spectral subtraction is widely used technique because of its simplicity and relatively good performance in noisy environments. In this paper, we introduce histogram method as a reliable noise estimation approach for spectral subtraction. This method has advantages over the conventional noise estimation methods in that it does not need to detect non-speech intervals and it can estimate the noise spectra even in time-varying noise environments. Even though spectral subtraction is performed using a reliable average noise spectrum by the histogram method, considerable amount of residual noise remains due to the variations of instantaneous noise spectrum about mean. To overcome this limitation, we propose a new over-estimation technique based on distribution characteristics of histogram used for noise estimation. Since the proposed technique decides the degree of over-estimation adaptively according to the measured noise distribution, it has advantages to be few the influence of the SNR variation on the noise levels. According to speaker-independent isolated word recognition experiments in car noise environment under various SNR conditions, the proposed histogram-based over-estimation technique outperforms the conventional over-estimation technique.

  • PDF

RGB Motion Segmentation using Background Subtraction based on AMF

  • Kim, Yoon-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.2
    • /
    • pp.81-87
    • /
    • 2013
  • Motion segmentation is a fundamental technique for analysing image sequences of real scenes. A process of identifying moving objects from data is a typical task in many computer vision applications. In this paper, we propose motion segmentation that generally consists from background subtraction and foreground pixel segmentation. The Approximated Median Filter (AMF) was chosen to perform background modeling. Motion segmentation in this paper covers RGB video data.

RGB Motion Segmentation using Background Subtraction based on AMF

  • Kim, Yoon-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 2014
  • Motion segmentation is a fundamental technique for analysing image sequences of real scenes. A process of identifying moving objects from data is a typical task in many computer vision applications. In this paper, we propose motion segmentation that generally consists from background subtraction and foreground pixel segmentation. The Approximated Median Filter(AMF) was chosen to perform background modeling. Motion segmentation in this paper covers RGB video data.

Digital Subtraction Technique for Intravenous X-ray Image System (컴퓨터 영상처리 방식을 이용한 정맥내 혈관 조영술 시스템 개발)

  • 이승지;이태수
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.109-116
    • /
    • 1981
  • The objective of this research is to develop the hardware and software systenls of the digital intravenous angiographic system. The system will be used in clinical diagnosis of cardiovascular and cerebrovascular diseases. By utilizing computer image processing technique and digital subtraction method, the system can decrease the patient's harzard and expenses in performing intravenous angiography, as compared with conventional angiograms of the arterial injection.

  • PDF

A study on the applications of the digital subtraction angiography imaging technique (디지탈 혈관 조영 장치의 영상기술 응용에 관한 연구)

  • 남문현;김성룡
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.684-689
    • /
    • 1987
  • Digital Subtraction Angiography(DSA) technique has been widely used to detect vascular diseases and hemodynamic parameters noninvasively. However, there are few quantitative studies on the factors in fluencing the resultant DSA image quality. In this paper, several important factors are suggested to improved the DSA image quality based on mathematical analysis. Experimental DSA images for different filters are shown and also discussed the difference between original and processed image quality.

  • PDF

Evaluation of mechanical and projective standardization in digital subtraction radiography (디지털 공제 방사선 촬영술에 있어서 기계적 및 투사적 규격화의 평가)

  • Choi Bong-In;Cho Bong-Hae;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.215-224
    • /
    • 1998
  • The following conclusions were obtained from the non-reconstructed and reconstructed subtraction images of the standard intraoral radiographs which were taken with paralleling technique with Rinn XCP only and with occlusal bite registration for geometric standardization using bilateral mandibular premolar and molar regions of two dry human skulls. 1. The SD of the overall subtraction images of the premolars and molars of the non-reconstructed, that is, the manual superimposition showed statistically significant difference between the non-registered and registered groups. 2. In non-reconstructed and non-registered cases, the quality of the subtraction images were improved when superimposition was focally done and this was more evident in areas where the radiographic images tend to be distorted due to anatomic reasons. 3. In non-reconstructed and registered cases, the subtraction images were consistent regardless of the anatomic site or the focus of superimposition. This means that the geometric standardization with only occlusal bite registration could produce serial radiographs which is suitable for subtraction. 4. The SD of the overall subtraction images of the premolars and molars of the reconstructed, that is, the automatic superimposition showed statistically insignificant difference between the non-registered and registered groups. This means that using reconstruction, subtraction radiography is possible without occlusal bite registration. 5. In reconstructed and non-registered cases, compatible quality of the subtraction images were obtained regardless of the anatomic site or area of the corresponding points. 6. In reconstructed and registered cases, best subtraction images whose quality showed sensitivity to the areas of corresponding points were obtained.

  • PDF