• Title/Summary/Keyword: subtraction image

Search Result 276, Processing Time 0.038 seconds

Diagnosis of Ictal Hyperperfusion Using Subtraction Image of Ictal and Interictal Brain Perfusion SPECT (발작기와 발작간기 뇌 관류 SPECT 감산영상을 이용한 간질원인 병소 진단)

  • Lee, Dong Soo;Seo, Jong-Mo;Lee, Jae Sung;Lee, Sang-Kun;Kim, Hyun Jip;Chung, June-Key;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.20-31
    • /
    • 1998
  • A robust algorithm to disclose and display the difference of ictal and interictal perfusion may facilitate the detection of ictal hyperfusion foci. Diagnostic performance of localizing epileptogenic zones with subtracted SPECT images was compared with the visual diagnosis using ictal and interictal SPECT, MR, or PET. Ietal and interictal Tc-99m-HMPAO cerebral perfusion SPECT images of 48 patients(pts) were processed to get parametric subtracted images. Epileptogenic foci of all pts were diagnosed by seizure free state after resection of epileptogenic zones. In subtraction SPECT, we used normalized difference ratio of pixel counts(ictal-interictal)/interictal ${\times}100%$) after correcting coordinates of ictal and interictal SPECT in semi-automatized 3-dimensional fashion. We found epileptogenic zones in subtraction SPECT and compared the performance with visual diagnosis of ictal and interictal SPECT, MR and PET using post-surgical diagnosis as gold standard. The concordance of subtraction SPECT and ictal-interictal SPECT was moderately good(kappa=0.49). The sensitivity of ictal-interictal SPECT was 73% and that of subtraction SPECT 58%. Positive predictive value of ictal-interictal SPECT was 76% and that of subtraction SPECT was 64%. There was no statistical difference between sensitivity or positive predictive values of subtraction SPECT and ictal-interictal SPECT, MR or PET. Such was also the case when we divided patients into temporal lobe epilepsy and neocortical epilepsy. We conclude that subtraction SPECT we produced had equivalent diagnostic performance compared with ictal-interictal SPECT in localizing epileptogenic zones. Additional value of these subtraction SPECT in clinical interpretation of ictal and interictal SPECT should be further evaluated.

  • PDF

A Study on the Improvement of Image Quality of the Digital Subtraction Angiography Unit (디지탈 혈관 조영장치의 화질 개선에 관한 연구)

  • Kim, Sung-Ryong;Nam, Mun-Hyon;Chung, Hwan;Yeon, Kyung-Mo
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.189-198
    • /
    • 1987
  • Digital Subtraction Angiography(DSA) technique has been widely used to detect vascular diseases and hemodynamic parameters noninvasively. However, there factors in fluencing the resultant DSA image quality. In this paper, several important factors are suggested to improve the DSA image quality based on mathematicical analysis. Experimental DSA images for different filters are shown and also dicussed the difference between original and processed image qualities.

  • PDF

A Study on the Extraction of Road & Vehicles Using Image Processing Technique (영상처리 기술을 이용한 도로 및 차량 추출 기법에 관한 연구)

  • Ga, Chill-O;Byun, Young-Gi;Yu, Ki-Yun;Kim, Yong-Il
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.13 no.4 s.34
    • /
    • pp.3-9
    • /
    • 2005
  • The extraction of traffic information based on image processing is under broad research recently because the method based on image processing takes less cost and effort than the traditional method based on physical equipment. The main purpose of the algorithm based on image processing is to extract vehicles from an image correctly. Before the extraction, the algorithm needs the pre-processing such as background subtraction and binary image thresholding. During the pre-processing much noise is brought about because roadside tree and passengers in the sidewalk as well as vehicles are extracted as traffic flow. The noise undermines the overall accuracy of the algorithm. In this research, most of the noise could be removed by extracting the exact road area which does not include sidewalk or roadside tree. To extract the exact road area, traffic lanes in the image were used. Algorithm speed also increased. In addition, with the ratio between the sequential images, the problem caused by vehicles' shadow was minimized.

  • PDF

Digital X-ray Imaging in Dentistry (치과에서 디지털 x-선 영상의 이용)

  • Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.387-396
    • /
    • 1999
  • In dentistry. RadioVisioGraphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter. many types of direct digital radiographic system have been produced in the last decade. They are based either on charge-coupled device(CCD) or on storage phosphor technology. In addition. new types of digital radiographic system using amorphous selenium. image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose. image processing, computer storage. electronic transfer of images and so on. Image processing includes image enhancement. image reconstruction. digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system(IMACS) for dentomaxillofacial radiology was reported in 1992. IMACS in dental hospital has been increasing. Meanwhile. researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible. feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis. have been performed actively in the last decade. Further developments in digital radiographic imaging modalities. image transmission system. imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  • PDF

A Background Subtraction Algorithm for Fence Monitoring Surveillance Systems (담장 감시 시스템을 위한 배경 제거 알고리즘)

  • Lee, Bok Ju;Chu, Yeon Ho;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.37-43
    • /
    • 2015
  • In this paper, a new background subtraction algorithm for video based fence monitoring surveillance systems is proposed. We adopt the sampling based background subtraction technique and focus on the two main issues: handling highly dynamic environment and handling the flickering nature of pulse based IR (infrared) lamp. Natural scenes from fence monitoring system are usually composed of several dynamic entities such as swaying trees, moving water, waves and rain. To deal with such dynamic backgrounds, we utilize the confidence factor for each background value of the input image. For the flickering IR lamp, the original sampling based technique is extended to handle double background models. Experimental results revealed that our method works well in real fence monitoring surveillance systems.

Automatic Registration of Images for Digital Subtraction Radiography Using Local Correlation (국소적 상관계수를 이용한 자동적 디지털 방사선 영상정합)

  • 이원진;허민석;이삼선;최순철;이재성
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.111-117
    • /
    • 2004
  • Most of digital subtraction methods in dental radiography are based on registration using manual landmarks. We have developed an automatic registration method without using the manual selection of landmarks. By restricting a geometrical matching of images to a region of interest (ROl), we compare the cross-correlation coefficient only between the ROIs. The affine or perspective transform parameters satisfying maximum of cross-correlation between the local regions are searched iteratively by a fast searching strategy. The parameters are searched on the 1/4 scale image coarsely and then, the fine registration is performed on the original scale image. The developed method can match the images corrupted by Gaussian noise with the same accuracy for the images without any transform simulation. The registration accuracy of the perspective method shows a 17% improvement over the manual method. The application of the developed method to radiography of dental implants provides an automatic noise robust registration with high accuracy in almost real time.

Usefulness of subtraction pelvic magnetic resonance imaging for detection of ovarian endometriosis

  • Lee, Hyun Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.2
    • /
    • pp.90-97
    • /
    • 2020
  • Background: To minimize damage to the ovarian reserve, it is necessary to evaluate the follicular density in the ovarian tissue surrounding endometriosis on preoperative imaging. The purpose of the present study was to evaluate the usefulness of subtraction pelvic magnetic resonance imaging (MRI) to detect ovarian reserve. Methods: A subtracted T1-weighted image (subT1WI) was obtained by subtracting unenhanced T1WI from contrast-enhanced T1WI (ceT1WI) with similar parameters in 22 patients with ovarian endometriosis. The signal-to-noise ratio (SNR) in ovarian endometriosis, which was classified into the high signal intensity and iso-to-low signal intensity groups on the T2-weighted image, was compared to that in normal ovarian tissue. To evaluate the effect of contrast enhancement, a standardization map was obtained by dividing subT1WI by ceT1WI. Results: On visual assessment of 22 patients with ovarian endometriosis, 16 patients showed a high signal intensity, and 6 patients showed an iso-to-low signal intensity on T1WI. Although SNR in endometriosis with a high signal intensity was higher than that with an iso-to-low signal intensity, there was no difference in SNR after the subtraction (13.72±77.55 vs. 63.03±43.90, p=0.126). The area of the affected ovary was smaller than that of the normal ovary (121.10±22.48 vs. 380.51±75.87 ㎟, p=0.002), but the mean number of pixels in the viable remaining tissue of the affected ovary was similar to that of the normal ovary (0.53±0.09 vs. 0.47±0.09, p=0.682). Conclusion: The subtraction technique used with pelvic MRI could reveal the extent of endometrial invasion of the normal ovarian tissue and viable remnant ovarian tissue.

A comparison of subtracted images from dental subtraction programs (디지털공제프로그램간의 디지털공제영상 비교)

  • Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

External Light Evasion Method for Large Multi-touch Screens

  • Park, Young-Jin;Lyu, Hong-Kun;Lee, Sang-Kook;Cho, Hui-Sup
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.4
    • /
    • pp.226-233
    • /
    • 2014
  • This paper presents an external light evasion method that rectifies the problem of misrecognition due to external lighting. The fundamental concept underlying the proposed method involves recognition of the differences between two images and elimination of the desynchronized external light by synchronizing the image sensor and inner light source of the optical touch screen. A range of artificial indoor light sources and natural sunlight are assessed. The proposed system synchronizes with a Vertical Synchronization (VSYNC) signal and the light source drive signal of the image sensor. Therefore, it can display synchronized light of the acquired image through the image sensor and remove external light that is not from the light source. A subtraction operation is used to find the differences and the absolute value of the result is utilized; hence, the order is irrelevant. The resulting image, which displays only a touched blob on the touchscreen, was created after image processing for coordination recognition and was then supplied to a coordination extraction algorithm.