• Title/Summary/Keyword: subtraction

Search Result 1,056, Processing Time 0.024 seconds

A Background Subtraction Algorithm for Fence Monitoring Surveillance Systems (담장 감시 시스템을 위한 배경 제거 알고리즘)

  • Lee, Bok Ju;Chu, Yeon Ho;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.37-43
    • /
    • 2015
  • In this paper, a new background subtraction algorithm for video based fence monitoring surveillance systems is proposed. We adopt the sampling based background subtraction technique and focus on the two main issues: handling highly dynamic environment and handling the flickering nature of pulse based IR (infrared) lamp. Natural scenes from fence monitoring system are usually composed of several dynamic entities such as swaying trees, moving water, waves and rain. To deal with such dynamic backgrounds, we utilize the confidence factor for each background value of the input image. For the flickering IR lamp, the original sampling based technique is extended to handle double background models. Experimental results revealed that our method works well in real fence monitoring surveillance systems.

Detection of Pulmonary Nodules' Shadow on Chest X-ray Image (흉부 X선 영상에 있어서 폐 종류 음영의 검출)

  • Kim, Eung-Kyeu;Lee, Do-Kyeom
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.293-294
    • /
    • 2007
  • The purpose of this study is prove the effectiveness of an energy subtraction image for the detection of pulmonary nodules and the effectiveness of multi-resolutional filter on an energy subtraction image to detect pulmonary nodules. Also we study influential factors to the accuracy of detection of pulmonary nodules from viewpoints of types of images, types of digital filters and types of evaluation methods. As one type of images, we select an energy subtraction image, which removes bones such as ribs from the conventional X-ray image by utilizing the difference of X-ray absorption ratios at different energy between bones and soft tissue. Here we select two evaluation methods and make clear the effectiveness of multi-resolutional filter on an energy subtraction image.

  • PDF

Identification of OH emission lines from IGRINS sky spectra and improved sky subtraction method

  • Lee, Jae-Joon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.72.2-72.2
    • /
    • 2019
  • The hydroxyl radical (OH) sky emission lines arise from the Earth's mesosphere, and they serve as a major source of the sky background in the infrared. With IGRINS, the observed line strength show non-negligible variation even within a few minutes of time scale, making its subtraction difficult. Toward the aim better sky subtraction in the IGRINS pipeline, we present 1) improved identification of sky lines in H and K band and 2) improved method of subtracting sky background. Using the recent line list of Brooke et al. (2015), we have detected ~500 OH doublets from upper vibrational level between 2 and 9 and maximum upper J level of 25. In particular, we found that a significant fraction of unidentified lines reported by Oliva et al. (2015) are indeed OH lines resulting from transitions between different F levels. With the extended line identification, we present an improved method of sky subtraction. The method, based on the method of Noll et al. (2014), empirically accounts non-LTE level population of OH molecules.

  • PDF

A discussion from a multi-dimensional curriculum perspective on how to instruct the computational estimation of addition and subtraction (덧셈과 뺄셈의 어림셈 지도 방식에 대한 다차원 교육과정적 관점에서의 논의)

  • Do, Joowon;Paik, Suckyoon
    • The Mathematical Education
    • /
    • v.59 no.3
    • /
    • pp.255-269
    • /
    • 2020
  • In this study, how to instruct the computational estimation of addition and subtraction was considered from the perspective of a 'intended-written-implemented' multi-dimensional curriculum. To this end, the 2015 revised elementary school mathematics curriculum as a intended curriculum and the 2015 revised first~sixth grade textbook as a written curriculum were analyzed with respect to how to instruct the computational estimation of addition and subtraction. As an implemented curriculum, a research study was conducted in relation to the method of instructing teachers about the computational estimation of addition and subtraction. As a result, first, it is necessary to discuss how to develop the ability to estimate and set it as a teaching goal and achievement standard in a separate curriculum to instruct it with learning content. Second, it is necessary to provide an opportunity to learn about various estimation methods by presenting specific activities so that students can learn the estimation itself in a separate operation method. Third, in order to improve the computational estimating ability of addition and subtraction, contents related to the computational estimation need to be included in the achievement criteria, and discussions on the expansion of the areas, and the diversification of the instructing time will be needed.

Noisy Speech Recognition using Probabilistic Spectral Subtraction (확률적 스펙트럼 차감법을 이용한 잡은 환경에서의 음성인식)

  • Chi, Sang-Mun;Oh, Yung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.94-99
    • /
    • 1997
  • This paper describes a technique of probabilistic spectral subtraction which uses the knowledge of both noise and speech so as to reduce automatic speech recognition errors in noisy environments. Spectral subtraction method estimates a noise prototype in non-speech intervals and the spectrum of clean speech is obtained from the spectrum of noisy speech by subtracting this noise prototype. Thus noise can not be suppressed effectively using a single noise prototype in case the characteristics of the noise prototype are different from those of the noise contained in input noisy speech. To modify such a drawback, multiple noise prototypes are used in probabilistic subtraction method. In this paper, the probabilistic characteristics of noise and the knowledge of speech which is embedded in hidden Markov models trained in clean environments are used to suppress noise. Futhermore, dynamic feature parameters are considered as well as static feature parameters for effective noise suppression. The proposed method reduced error rates in the recognition of 50 Korean words. The recognition rate was 86.25% with the probabilistic subtraction, 72.75% without any noise suppression method and 80.25% with spectral subtraction at SNR(Signal-to-Noise Ratio) 10 dB.

  • PDF

Age determination of bricks related to Muryong Royal Tomb of the Baekje Kingdom using subtraction method (감쇄기법(subtraction method)을 이용한 백제 무령왕릉 관련 전(塼)의 연대결정)

  • Kim, Myung-Jin;Song, Ki-Woung;Lee, Chan-Hee;Jang, Sung-Yoon;Takashima, Isao;Hong, Duk-Geun
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.508-515
    • /
    • 2007
  • Age determination was carried out with the bricks relating to Muryong Royal Tomb of the Baekje Kingdom, for which there is no information on the external gamma dose rate, by using the subtraction method of luminescence dating. In the subtraction method, each paleodose for fine grain and for quartz inclusion is required for the sample to be dated. In this study, the paleodose for the fine grain was estimated by thermoluminescence measurement and the paleodose for the quartz inclusion was determined using optically stimulated luminescence. The resultant ages among the bricks showed good agreement with standard deviation of 6 % error. Finally the bricks relating to Muryong Royal Tomb were evaluated as AD $530{\pm}50yrs$($1{\sigma}$ SD).

Normalized Cross Correlation-based Multiview background Subtraction for 3D Object Reconstruction (3차원 객체 복원을 위한 정규 상관도 기반 다중 시점 배경 차분 기법)

  • Paeng, Kyunghyun;Hwang, Sung Soo;Kim, Hee-Dong;Kim, Sujung;Yoo, Jisung;Kim, Seong Dae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.228-237
    • /
    • 2013
  • In this paper, we propose a normalized cross correlation(NCC)-based multiview background subtraction method which is robust when an object and background have similar color. When the background of the capturing environment is not artificially composed, the regions in the background images which would be occluded by an object tends to have difference colors. The colors of those regions, however, becomes similar when an object enters the capturing environment. Based on this assumption, this paper proposes a concept of GoNCC(Graph of Normalized Cross Correlation). GoNCC is the distribution of NCC between a pixel in an image and pixels related by epipolar constraints with the pixel. The proposed multiview background subtraction method is performed by comparing GoNCC of the current images with the background images. To reduce computational complexity, we perform multiview background subtraction only to the pixels undetermined by single view background subtraction. Experimental results show that the proposed method is more robust to color similarity between an object and background than a single-view background subtraction method and a previous multiview background subtraction method.

A Study of the Elementary School Teachers' Perception about Problem Situations in Real-Life Context of Subtraction of Natural Numbers (자연수 뺄셈의 실생활 맥락 문제 상황에 대한 초등교사의 인식)

  • Do, Joowon
    • Education of Primary School Mathematics
    • /
    • v.25 no.2
    • /
    • pp.197-211
    • /
    • 2022
  • In this study, we tried to find a way to improve the pedagogical decision-making practices related to the presentation order of 'large number' and 'small number' in problem situations of subtraction of the natural number. For this purpose, the elementary school teachers' perception about problem situations in real-life context of subtraction of natural numbers was investigated, and the collected data were analyzed qualitatively and quantitatively to identify teachers' pedagogical perceptions. As a result of this study, it was confirmed the need for consideration on how to set up a problem situations in real-life context of subtraction so that students can develop their ability to solve various types of problems. To this end, not only in a problem situation of subtraction where you have to think of 'large number' first and 'small number' later, but also about the introduction of problem situations in real-life context of subtraction in which you think about 'small number' first and 'large number' later, which often appears in real-life. You will need to recognize the need. And you should have a pedagogical view on this. The results of this study will be able to contribute to the preparation of pedagogical method that can expand the understanding of various problem situations where subtraction is applied from the lower grades of elementary school.

The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method (Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method)

  • Choi, Jong-Sook;Jung, Woo-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.102-109
    • /
    • 2009
  • Purpose: Flash 3D (pixon(R) method; 3D OSEM) was developed as a software program to shorten exam time and improve image quality through reconstruction, it is an image processing method that usefully be applied to nuclear medicine tomography. If perfoming brain diamox perfusion scan by reconstructing subtracted images by Flash 3D with shortened image acquisition time, there was a problem that SNR of subtracted image is lower than basal image. To increase SNR of subtracted image, we use LEAP collimators, and we emphasized on sensitivity of vessel dilatation than resolution of brain vessel. In this study, our purpose is to confirm possibility of application of LEAP collimators at brain diamox perfusion tomography, identify proper reconstruction factors by using Flash 3D. Materials and methods: (1) The evaluation of phantom: We used Hoffman 3D Brain Phantom with $^{99m}Tc$. We obtained images by LEAP and LEHR collimators (diamox image) and after 6 hours (the half life of $^{99m}Tc$: 6 hours), we use obtained second image (basal image) by same method. Also, we acquired SNR and ratio of white matters/gray matters of each basal image and subtracted image. (2) The evaluation of patient's image: We quantitatively analyzed patients who were examined by LEAP collimators then was classified as a normal group and who were examined by LEHR collimators then was classified as a normal group from 2008. 05 to 2009. 01. We evaluate the results from phantom by substituting factors. We used one-day protocol and injected $^{99m}Tc$-ECD 925 MBq at both basal image acquisition and diamox image acquisition. Results: (1) The evaluation of phantom: After measuring counts from each detector, at basal image 41~46 kcount, stress image 79~90 kcount, subtraction image 40~47 kcount were detected. LEAP was about 102~113 kcount at basal image, 188~210 kcount at stress image and 94~103 at subtraction image kcount were detected. The SNR of LEHR subtraction image was decreased than LEHR basal image about 37%, the SNR of LEAP subtraction image was decreased than LEAP basal image about 17%. The ratio of gray matter versus white matter is 2.2:1 at LEHR basal image and 1.9:1 at subtraction, and at LEAP basal image was 2.4:1 and subtraction image was 2:1. (2) The evaluation of patient's image: the counts acquired by LEHR collimators are about 40~60 kcounts at basal image, and 80~100 kcount at stress image. It was proper to set FWHM as 7 mm at basal and stress image and 11mm at subtraction image. LEAP was about 80~100 kcount at basal image and 180~200 kcount at stress image. LEAP images could reduce blurring by setting FWHM as 5 mm at basal and stress images and 7 mm at subtraction image. At basal and stress image, LEHR image was superior than LEAP image. But in case of subtraction image like a phantom experiment, it showed rough image because SNR of LEHR image was decreased. On the other hand, in case of subtraction LEAP image was better than LEHR image in SNR and sensitivity. In all LEHR and LEAP collimator images, proper subset and iteration frequency was 8 times. Conclusions: We could archive more clear and high SNR subtraction image by using proper filter with LEAP collimator. In case of applying one day protocol and reconstructing by Flash 3D, we could consider application of LEAP collimator to acquire better subtraction image.

  • PDF

Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image (Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성)

  • Moon, A-Reum;Chi, Yong-Gi;Choi, Sung-Wook;Lee, Hyuk;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Purpose: PET/CT combines functional and morphologic data and increases diagnostic accuracy in a variety of malignancies. Especially reconstructed Fusion PET/CT images or MIP (Maximum Intensity Projection) images from a 2-dimensional image to a 3-dimensional one are useful in visualization of the lesion. But in Fusion & MIP 3D reconstruction image, due to hot uptake by urine or urostomy bag, lesion is overlapped so it is difficult that we can distinguish the lesion with the naked eye. This research tries to improve a distinction by removing parts of hot uptake. Materials and Methods: This research has been conducted the object of patients who have went to our hospital from September 2008 to March 2009 and have a lot of urine of remaining volume as disease of uterus, bladder, rectum in the result of PET/CT examination. We used GE Company's Advantage Workstation AW4.3 05 Version Volume Viewer program. As an analysis method, set up ROI in region of removal in axial volume image, select Cut Outside and apply same method in coronal volume image. Next, adjust minimum value in Threshold of 3D Tools, select subtraction in Advanced Processing. It makes Fusion & MIP images and compares them with the image no using Region Cut Definition. Results: In Fusion & MIP 3D reconstruction image, it makes Fusion & MIP images and compares them by using Advantage Workstation AW4.3 05's Region Cut Subtraction, parts of hot uptake according to patient's urine can be removed. Distinction of lesion was clearly reconstructed in image using Region Cut Definition. Conclusion: After examining the patients showing hot uptake on account of volume of urine intake in bladder, in process of reconstruction image, if parts of hot uptake would be removed, it could contribute to offering much better diagnostic information than image subtraction of conventional method. Especially in case of disease of uterus, bladder and rectum, it will be helpful for qualitative improvement of image.

  • PDF