• 제목/요약/키워드: substations

검색결과 295건 처리시간 0.027초

IEC 61850 SCL기반 변전소 자동화 시스템의 구성방법 (Substation Automation System Design Process Based on IEC 61850 SCL)

  • 장대붕;임성정;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.62-64
    • /
    • 2006
  • With the advent of the international standard IEC 61850 for communication networks and systems in substations, utilities are beginning to implement substation automation systems (SAS) that can give support to interoperability, interchangeability and self-description features. This paper describes with the SAS design accordance with this new standard. After a brief introduction of IEC 61850 SCL, this paper addresses some issues related to the specification of an IEC 61850 based SAS, and describes the Substation Configuration Language (SCL) based on Extensible Markup Language (XML). The SAS design process is explored with examples including the Intelligent Electronic Device (IED) selection, Logical Nodes (LN) allocation and the related services and the SAS communication architecture.

  • PDF

미얀마 500kV 송전망 기본설계 (Basic Design for the 500kV Transmission System In Myanmar)

  • 백승도;김종화;최영성;한성민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.40-41
    • /
    • 2006
  • KEPCO conducted the project called the "Feasibility Study & Basic Designs for the 500kV Transmission System in Myanmar" as its second overseas project following the "Development Study on the Power System Network Analysis in Myanmar" as it first project. This paper deals with the design processes and results of 423 kilometers of the 500kV single circuit transmission lines and three substations. The main contents of the basic design include insulation design, transmission line design and substation design.

  • PDF

고온초전도 선의 전력 응용을 위한 실시간 시뮬레이션 알고리즘 개발 (Development of a real-time simulation algorithm for the application of the HTS tape)

  • 강진주;김재호;제항호;조전욱;심기덕;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.260-261
    • /
    • 2006
  • This paper describes a real time digital simulation method for the application of HTS tape to power devices. At present, in order to extend the power capacity of some area which has a serious problem of power quality, especially metropolitan complex city. there are so many problems such as ROW for cable line routes, space for downtown substations, and the environmental protection, etc. HTS technology is one of the best solutions. Simulation is required for safety before install of HTS power cable, a fabrication model used at the power system simulation. Here, in this paper, authors developed an algorithm connected with HTS by using Real-Time Digital Simulator(RTDS).

  • PDF

우리나라계통의 북상조류 증대를 위한 FACTS 적용방안 연구 (Feasibility Study of FACTS Application for Available Transfer Capability Enhancement in Korean Power System)

  • 장병훈;문승필;윤종수;김수열;백두현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.63-65
    • /
    • 2005
  • Korea Electric Power Corporation (KEPCO) is in charge of the operation and the maintenance for transmission lines and substations in Korean power system which is under the deregulation power market. KEPCO has a main constrain of transmission line toward SEOUL area which is a capital of KOREA because SEOIJL is a huge load of Korean power system. The Korea Electric Power Research Institute (KEPRI)), a division of KEPCO was tasked to study the ATC enhancement of transmission line toward SEOUL using a new line or/and FACTS. This paper summarizes the results of those studies, enhancing the ATC and evaluating the economics.

  • PDF

다른계통으로 연계된 두개의 변전소의 배전계통 특성 연구 (Study on Distribution System Characteristic Of Two Substations Coupling Different Power Systems)

  • 권오형;문봉수;김태옥;강유원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.670-672
    • /
    • 2005
  • 발전원이 다른 계동으로 연계된 춘천, 남춘천변전소의 태전선로간 Loop 시행시 일부배전선로가 Trip되는 현상에 대하여 PSSE 검토 TOOL을 활용하여 계통을 모의하고 변압기 병렬운전조건에 대한 물리적 의미와 검토대상 배전선로 계통특성, 주변 발전원의 발전력과의 상관관계를 기술검토를 통하여 계통특성을 분석함으로써 Loop시행이 가능한 계통여건을 파악, 선로 운영의 최적방안을 제시하고자 한다.

  • PDF

국내 변전설계를 위한 전력용변압기 기준(안)에 관한 연구 (A Study on the Criteria of Power Transformers for Substation Design in Korea)

  • 김익수;윤진열;주병수;이옥배;윤유술;정주영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.132-134
    • /
    • 2005
  • This paper represents the criteria of Power Transformers for substation design in Korea. The construction of new substations and expansion of existing facilities are commonplace projects in KEPCO(Korea Electric Power Corporation). The KEPCO has had the only design criteria, which need to be adequate criteria considering the new technology and environment in Korea.

  • PDF

Modeling and prediction of rapid pollution of insulators in substations based on weather information

  • Nanayakkara, Nishantha;Nakamura, Masatoshi;Goto, Satoru;Taniguchi, Takashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.202-206
    • /
    • 1994
  • Mathematical model of the pollution rate of substation insulators is constructed, taking the model parameters as wind speed, wind direction, typhoon conditions and rainfall in an hourly basis. The main feature of model construction is to distinguish the effect of each parameter by separately analyzing the positive and negative pollution causing factors. Model parameters for the insulators of Karatsu substation, Saga, Japan were estimated and model validation was done using the actual data, in which the pollution deposits on the insulators were measured using pilot insulator and 'salt meter'. The proposed model of the pollution rate [mg/cm$^{2}$/hr] enables the identification of the effective parameters and prediction of the pollution rate so that it helps for the automatic decision making for insulator cleaning or the model can be used as a tool for the substation engineers to make precautionary measures.

  • PDF

초전도 한류기를 포함한 계통의 단락사고에 대한 EMTDC 해석 (Am EMTDC Analysis for Line Faults with a Superconducting Fault Current Limiter)

  • 최효상;황시돌;현옥배;정상진
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.101-105
    • /
    • 1999
  • We have performed an EMTDC simulation for the current limiting effects of a superconducting fault current limiter (SFCL). The fault currents in the 154 kV transmission line between the Gaepo and Sungnam substations increased up to 54kA and 60kA during the line-to-line and three phase faults, respectively. The SFCL with 100 $\Omega$ of impedance after quench limited the currents to less than 17 kA within a half cycle. This limited current is well below the upper limit of a circuit breaker, suggesting that the impedance of the SFCL in the transmission line is sufficient.

  • PDF

직류전력 회생용 인버터의 고조파 저감에 관한 연구 (A Study on Harmonic Reduction in Inverters for DC Power Regeneration)

  • 김명수;윤인식;박영진;윤덕용;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.464-468
    • /
    • 1999
  • This paper deals with the harmonic reduction technique in square-wave inverters which can regenerate the dc power from dc bus line to ac bus line in substations for traction systems. To reduce the harmonics, two 6-pulse inverters are used for 12-pulse operation and zigzag-connected output transformers for eliminating the harmonics of 6(2m-1)$\pm$1 orders. And an ac filter is furnished at output side. In spite of the square-wave three-phase inverters, computer simulations show that the THDs of the output voltage and current are 2.55% and 0.554%, respectively.

  • PDF

고장전류 저감을 위한 초전도 한류기 적용 (SCFL Application for Reducing Fault Current)

  • 김학만;김종율;최상봉;문영환;성기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.206-208
    • /
    • 2002
  • The transmission system is designed to be protected by 40 kA rate of circuit breaker fer 345 tV system and 31.5 kA and 50 kA rate of circuit breaker for 154 kV system. The short circuit current shows the tendency of exceeding circuit breaker duty for some substations and the tendency will continue if an appropriate countermeasure will not be applied to. In order to solve this problem from the viewpoint of system operation, the 154 kV system is under reconfiguration to be radial systems. This paper presents application effect of resistive and inductive SCFL (Superconducting Fault Current Limiter to Korea power systems. An algorithm of SCFL site decision is suggested.

  • PDF