• Title/Summary/Keyword: submarine cable

Search Result 114, Processing Time 0.028 seconds

Analysis of the Transient Dynamic Response of Ocean Mining Pipe System Due to Impulse (임펄스 가진에 의한 근해역 통합채광시험 양광시스템의 파이프 동적 과도응답 해석)

  • Cho, Kyu-Nam;Kim, Min;Park, Yong-Chan;Yoon, Chi-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • A finite element analysis scheme is proposed to assess the dynamic response due to impulse excitation of ocean mining pipe system. Transient dynamic response analysis based on the proposed scheme was carried out for various types of impulses, and the magnitude of cable tension induced by impulse was discussed by using a model of 'Segero', a special purpose ship of KT-Submarine as well as ROV carrier 'Onnuri' A qualitative, prospective guideline for the relevant marine operation is obtained.

The Study on the AC Interference of High Power Cable on Underground Gas Pipeline (전력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구)

  • Bae, J.H.;Kim, D.K.;Ha, T.H.;Lee, H.G.;Kwak, B.M.;Lim, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.470-473
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power. Therefore, there has been and still is a growing concern (safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline. especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion, limitation of safety voltage and analysis of indiction voltage.

  • PDF

Collision Behavior Evaluation of Flexible Concrete Mattress Depending on Material Models (재료모델에 따른 유연 콘크리트 매트리스의 충돌 거동 평가)

  • Ryu, Yeon-Sun;Cho, Hyun-Man;Kim, Seo-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.70-77
    • /
    • 2015
  • The purpose of this study was to provide fundamental data for an anchor collision simulation of an FCM (flexible concrete mattress). Numerical material models (elastic-perfectly plastic model, Drucker-Prager model, and RHT concrete model) were compared. ANSYS Explicit Dynamics was used for collision analyses. An FE model was used for the anchor, FCM, andreinforcement bars. The results showed that the behavior of the FCM was verydifferent that those ofthe material models. In particular, the effect of the pressure dependent strength was most noticeable among the properties of concrete.

Study on the Method to minimize Measuring Burial Depth Error for Submarine Cable (해저케이블 매설심도 측정오차 저감 방법에 관한 연구)

  • An, Yong-Ho;Kim, Yong-Hak;Han, Jeong-Yeol;Lee, You-Jin;Shim, Eung-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2101-2102
    • /
    • 2011
  • 우리나라의 도서지역 전력공급을 담당하고 있는 배전 해저 케이블은 대부분 남해안에 설치되어 있으며, 그 다음으로 서해안 그리고 제주도에 설치되어 있다. 해저케이블 설치방법은 매설방식에 따라 매설 방식과 비 매설방식으로 분류되는데 한국전력공사에서는 배전 해저케이블의 경우 2003년부터 전량 매설방식으로 시공하고 있다. 매설방식으로 해저케이블을 시공할 경우 매설상태의 적합성 여부 판단은 '매설심도'로 판단할 수밖에 없으며, 특히 해저면에 매설된 해저케이블의 매설심도를 어떻게 정확하게 측정해 내느냐가 중요한 Issue로 대두되고 있다. 본 논문에서는 전기적인 탐사방법 중 자계검출방식을 이용하여 해저케이블 매설심도를 측정할 경우 해저케이블 접지환경 등 전기적인 요인에 의해 매설심도의 측정오차가 발생할 수 있는 것과 측정오차를 저감할 수 있는 방법 및 특성에 관해 연구하였다.

  • PDF

A study on Yeosu area communication history in the old documents II (고문서에 나타난 여수지역 통신역사에 관한 고찰 II)

  • Kim, Chun-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.5
    • /
    • pp.945-953
    • /
    • 2012
  • Yeosu area from the old historical monuments and artifacts related communications signal station, directions display panels, lighthouse, Geomundo the first submarine cable installation, etc. That appears in old documents and communications of the area should check the history and development of communication in understanding the Yeosu area and communicate the need to identify resources historicity.

The cases of applying submarine optical fiber cable to control HVDC link between JEJU and main land (육지-제주간 초고압직류연계선로 제어용 해저광통신케이블 도입사례)

  • Yoo, Sung-Hwan;Yoo, Dong-Hee;Hong, Seung-Taek;Shin, Hyun-Jo;Joo, Jae-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.400-402
    • /
    • 2008
  • 제주도의 지속적인 전력수요 증가에 능동적으로 대처하고자 육지-제주간 초고압 직류연계(HVDC) 추가 건설사업이 추진 중에 있다. 초고압 직류 송전계통을 신뢰성 있게 운전하기 위해 양측 변환소에 설치될 제어 및 감시계통간 정보전송로의 화보는 매우 중요하다. 본 논문에서는 고품질, 대용량화 되어가는 전력데이터를 안정적으로 전송하고 해저케이블 고장감시 및 향후 정보 통신 분야의 부가가치 창출을 위한 최적의 해저광통신케이블을 소개하고자 한다.

  • PDF

A Study on the 3-D Digital Modelling of the Sea Bottom Topography (3차원 해저지형 수치모델에 관한 연구)

  • 양승윤;김정훈;김병준;김경섭
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.33-44
    • /
    • 2002
  • In this study, 3-dimensional virtual visualization was performed for a rapid and accurate analysis of sea bottom topography. The visualization was done through the extracted data using the developed program and the generated data using the gridding method. The data extraction program was developed with AutoLISP programming language and this program was able to extract the needed sample bathymetry data from the electronic sea chart systematically as well as effectively The gridded bathymetry data were generated by the interpolation or extrapolation method from the spatially-irregular sample data. As the result of realization for the 3-dimensional virtual visualization, it was shown a proper feasibility in the analysis of the sea bottom topography to determine the route of submarine cable burial.

The First Installation of 154kV AC Submarine Power Cable System in Korea (국내 최초 154kV AC 해저케이블 건설)

  • Shon, Hyoung-Soo;Min, Byeong-Wook;Im, Jong-Ryeal;Kim, Jae-Seung;Hong, Jong-Chun;Lee, Ik-Heung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.572-573
    • /
    • 2011
  • 본 논문에서는 신안군 도서지역의 안정적 전력공급 및 해저송전선로 건설기술 국산화를 위하여 국내 최초로 제작, 설치된 154kV급 AC 해저송전선로에 대한 케이블 구조, 시스템 및 보호공법 등 전반적인 내용에 대하여 소개하였다.

  • PDF

Fault Location Guideline for Deep Sea Submarine Cable (해저케이블 고장점탐지기술 가인드라인 제시)

  • Park, Jun-Woo;Yang, Byung-Mo;Choi, Kyoung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.139-140
    • /
    • 2008
  • 해저케이블의 고장은 aging, 부식, 과부하, 과도전압, 기계적인 영향에 의해서 고장이 발생하며 이 중 선박앵커에 의한 외부절연체 파괴로 인한 고장의 가능성군 가장 높다. 특히, 제주-해남간 해저케이블은 고장발생시 경제적, 사회적으로 미치는 영향이 크기 때문에 유사시에 대비한 고장점탐지 기술확보가 매우 중요하다. 본 논문에서는 해저케이블 고장발생시 케이블고장확인 및 고장점탐지 기술에 대한 가이드라인을 제시하고자 한다.

  • PDF

Reliability Test for the Repairing Joint in HVDC Sea Submarine Cable (HVDC 해저케이블 접속재 신뢰성 평가를 위한 인정시험)

  • Yang, B.M.;Park, H.S.;Park, J.W.;Kim, J.C.;Kang, J.W.;Yoon, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.77-78
    • /
    • 2008
  • HVDC 케이블은 장거리 전력전송, 국가간 계통연계 비동기 전력계통연계, 전력의 시장화에 따른 전력공급 제어 필요에 따라 세계적으로 널리 사용되고 있다. 국내에서는 현재 유일하게 제주-해남간 HVDC 해저케이블이 운영 중에 있으며, 향후 제주도 안정적인 전력공급을 위하여 2011년에 제주-육지간 HVDC 해저케이블이 추가로 건설될 예정이다. 그래서 HVDC 해저 케이블의 안정적이고 신뢰성 있는 운영을 하기 위한 보수자재용 접속재 개발 및 신뢰성 평가가 필요하게 되었다. 본 논문에서는 제주-해남간 운영중인 HVDC 해저케이블 보수자재용으로 개발된 접속재에 대한 신뢰성 평가 방법으로 가장 많이 사용되고 있는 Electra 175, 189의 기계적 및 전기적 평가에 대하여 기술하고자 한다.

  • PDF