• Title/Summary/Keyword: styrene

Search Result 1,667, Processing Time 0.032 seconds

A Study on Migration of Monomers from Kitchen Utensils Including PA, PU, ABS, and Acrylic Resin Plastics (폴리아마이드제 등 조리기구 중 모노머의 이행에 관한 연구)

  • Choi, Jae-Chon;Park, Se-Jong;Park, Geon-Woo;Min, Hye-Kyoung;Yang, Ji-Young;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.1
    • /
    • pp.81-86
    • /
    • 2015
  • The purpose of our paper was to investigate the migration level of 4,4'-MDA(4,4'-methylenedianiline), 2,4-TDA(2,4-toluenediamine), aniline, acrylonitrile and methylmeth acrylate from plastic cookwares into food simulants and to evaluate the safety of each monomers. The test articles for monomers were PA (polyamide) items for 4,4'-MDA, 2,4-TDA and aniline, PU (polyurethane) items for 4,4'-MDA, ABS (acrylonitrile-butadiene- styrene) items for acrylonitrile, and acrylic resin items for methylmethacrylate. All the article samples of 321 intended for contact with foods were purchased in domestic market. 4,4'-MDA, 2,4-TDA and aniline were analyzed by LC-MS/MS (liquid chromatography -tandem mass spectrometer), acrylonitrile by GC-NPD (gas chromatography-nitrogen phos phorus detector) and methyl methacrylate by GC-FID (gas chromatography-flame ionization detector). The migration level of monomers were within the migration limits of Ministry of Food and Drug Safety (MFDS). As a result of safety evaluation, our results showed that the estimated daily intake (EDI, mg/kg bw/day)s were $2.39{\times}10^{-9}$ and $1.20{\times}10^{-9}$ for 4,4'-MDA and 2,4-TDA of PA, $4.32{\times}10^{-9}$ for acrylonitrile of ABS and $2.27{\times}10^{-7}$ for methylmethacrylate of acrylic resin. Reference Dose (RfD, mg/kg bw/day) of acrylonitrile and tolerable daily intake (TDI, mg/kg bw/day) of methacrylate were established respectively as 0.001 by EPA (US Environmental Protection Agency) and as 1.2 by WHO (World Health Organization). When comparing with RfD and TDI, the EDIs of acrylonitrile and methylmethacrylate accounted for $4.32{\times}10^{-4}%$ and $1.89{\times}10^{-5}%$ respectively.

A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area (대형건축물 저수조의 수질실태 및 개선방안에 관한 연구)

  • Lee, J.H.;Lee, H.H.;Kim, H.B.;Ahn, G.W.;Park, K.N.;Kim, Y.K.;Bae, J.S.;Mun, H.;Park, C.U.;Oh, E.H.;Park, S.I.;Seo, Y.G.
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

The Concentration of Indoor Air Quality and Correlations of Materials at Multiple-use Facilities in Gwangju (광주지역 다중이용시설에서 실내공기질 농도와 상관성 분석)

  • Lee, Dae-Haeng;Lee, Se-Haeng;Bae, Seok-Jin;Kim, Nan-Hee;Park, Kang-Soo;Kim, Do-Sool;Paik, Ke-Jin;Moon, Yong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.11
    • /
    • pp.1001-1010
    • /
    • 2010
  • The purpose of this study is to investigate the concentration levels of particle materials ($PM_{10}$, asbestos), gas materials ($CO_2$, CO, $NO_2$, HCHO, Rn, VOCs) and total suspended colony (TSC), and the correlations among these materials in indoor air quality of 54 multiple-use facilities and 15 public-use facilities of Gwangju. The highest mean concentration of $PM_{10}$ was $69.2\;{\mu}g/m^3$ at indoor parking place, followed by childcare facilities, large commercial building and subway station building. The highest mean concentration of CO was 2.7 ppm at indoor parking place and that of $CO_2$ was 604.1 ppm at medical service facilities. The highest mean concentration of $NO_2$ was 0.036 ppm at indoor parking place. The geomean concentration of HCHO was $3.6\;{\mu}g/m^3$ in all facilities and the highest was $631.8\;{\mu}g/m^3$ at art gallery. The geomean concentration of VOCs (5 species) was $24.14\;{\mu}g/m^3$ in all facilities and toluene was the highest material of $15.30\;{\mu}g/m^3$, followed by xylene, ethylbenzene, benzene and styrene. The highest mean concentration of TSC was $625.3\;CFU/m^3$ at jjimjilbang, followed by childcare facilities, medical service facilities and large commercial building. The highest of asbestos was 0.0072 each/cc at childcare facilities and that of radon was 1.41 pCi/L at art gallery. PM10 showed positive correlations to TSC with $R^2\0.5332$ by lognormal equation at childcare facilities. CO2 showed positive correlations to CO at childcare facilities and indoor parking place. Lognormal equation fitted to the VOCs data more than normal equation in all facilities.

Preparation of Polystyrene Beads by Suspension Polymerization with Hydrophobic Silica as a Stabilizer in Aqueous Solution (소수성 실리카를 안정제로 이용하는 수용액 상에서의 현탁중합법에 의한 폴리스티렌 입자 합성)

  • Park, Moon-Soo
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.498-504
    • /
    • 2006
  • A suspension polymerization of styrene In aqueous phase was employed to study if polystyrene particles ranging from 1 to $20{\mu}m$ can be produced. Hydrophobic silica was selected as a stabilizer and azo-bisisobutyronitrile (AIBN) as an initiator. Polymerization reaction was carried out at a selected temperature in the range of $65{\sim}95^{\circ}C$. Stabilizer concentration was varied from 0.17 to 3.33 wt% compared to the water while the concentration of the initiator was raised from 0.13 to 6.0 wt% compared to the monomer. Dispersion of hydrophobic silica into the water phase was achieved by precise control of pH. Optimum dispersion of silica was obtained at pH 10. Average particle diameter decreased with increasing amounts of stabilizer concentration initially, exhibiting the minimum average diameter at 1.67 wt% of stabilizer concentration, after which it started to Increase. It is speculated that an excessive presence of stabilizer encouraged a secondary reaction in the reaction medium, which led to particle agglomeration, and as a result an increase in average particle diameter. Molecular weight was found to be independent of stabilizer concentration between 0.13 and 1.00 wt% whereas, it increased when stabilizer concentration exceeded 1.67 wt%. Variation of molecular weight was probably caused by the reduced activity and efficiency of initiator due to the high concentration of silica, and the secondary reaction in the reaction medium, as well. An increase in the Initiator concentration and/or reaction temperature resulted in an increase in both reaction rate and particle diameter. Consequently, we have confirmed that spherical polystyrene particles with $1{\sim}20{\mu}m$ in diameter can be prepared by careful selection of the concentration of stabilizer, initiator, pH and reaction temperature.

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.

Structure Analysis and Scale Model Test for Strength Performance Evaluation of Submersible Mooring Pulley Installed on Floating Offshore Wind Turbine (부유식 해상풍력발전기용 반잠수식 계류 풀리의 강도 성능평가를 위한 구조해석과 축소 모형시험)

  • Chang-Yong Song
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.5
    • /
    • pp.479-487
    • /
    • 2023
  • Recently, the destructive power of typhoons is continuously increasing owing to global warming. In a situation where the installation of floating wind turbines is increasing worldwide, concerns about the huge loss and collapse of floating offshore wind turbines owing to strong typhoons are deepening. A new type of disconnectable mooring system must be developed for the safe operation of floating offshore wind turbines. A new submersible mooring pulley considered in this study is devised to more easily attach or detach the floating of shore wind turbine with mooring lines compared with other disconnectable mooring apparatuses. To investigate the structural safety of the initial design of submersible mooring pulley that can be applied to an 8MW-class floating type offshore wind turbine, scale-down structural models were developed using a 3-D printer and structural tests were performed on the models. For the structural tests of the scale-down models, tensile specimens of acrylonitrile butadiene styrene material that was used in the 3-D printing were prepared, and the material properties were evaluated by conducting the tensile tests. The finite element analysis (FEA) of submersible mooring pulley was performed by applying the material properties obtained from the tensile tests and the same load and boundary conditions as in the scale-down model structural tests. Through the FEA, the structural weak parts on the submersible mooring pulley were reviewed. The structural model tests were conducted considering the main load conditions of submersible mooring pulley, and the FEA and test results were compared for the locations that exceeded the maximum tensile stress of the material. The results of the FEA and structural model tests indicated that the connection structure of the body and the wheel was weak in operating conditions and that of the body and the chain stopper was weak in mooring conditions. The results of this study enabled to experimentally verify the structural safety of the initial design of submersible mooring pulley. The study results can be usefully used to improve the structural strength of submersible mooring pulley in a detailed design stage.

A study on the calibration characteristics of organic fatty acids designated as new offensive odorants by cryogenic trapping-thermal desorption technique (유기지방산 신규악취물질에 대한 저온농축 열탈착방식 (Thermal desorber)의 검량특성 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Im, Moon-Soon;Ju, Do-Weon
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.488-497
    • /
    • 2009
  • In this study, analytical methodology for several organic fatty acids (OFA: propionic acid (PA), butyric acid (BA), isovaleric acid (IA), and valeric acid (VA)) designated as new offensive odorants in Korea (as of year 2010) was investigated along with some odorous VOCs (styrene, toluene, xylene, methyl ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol). For this purpose, working standards (WS) containing all of these 13 compounds were loaded into adsorption tube filled with Tenax TA, and analyzed by gas chromatography (GC) system thermal desorber interfaced with. The analytical sensitivities of organic fatty acids expressed in terms of detection limit (both in absolute mass (ng) and concentration (ppb)) were lower by 1.5-2 times than other compounds (PA: 0.24 ng (0.16 ppb), BA: 0.19 ng (0.11 ppb), IA: 0.15 ng (0.07 ppb), and VA: 0.28 ng (0.13 ppb)). The precision of BA, IA, and VA, if assessed in terms of relative standard error (RSE), maintained above 5%, while the precison of other compounds were below 5%. The reproducibility of analysis improved with the aid of internal standard calibration (PA: $1.1{\pm}0.4%$, BA: $10{\pm}0.46$, IA; $12{\pm}0.3%$, VA: $4{\pm}0.1%$), respectively. The results of this study showed that organic fatty acid can be analyzed using adsorption tube and thermal desorber in a more reliable way to replace alkali absorption method introduced in the odor prevention law of the Korea Ministry of Environment (KMOE).