• 제목/요약/키워드: stylus

검색결과 127건 처리시간 0.019초

접촉식 형상 측정기에 의한 표면 미세 형상 측정시 촉침 반경이 측정오차에 미치는 영향 (Effects of stylus tip radius on the measuring error in surface topography measurement by contact stylus profilometer)

  • 권기환
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.613-617
    • /
    • 2000
  • This paper descries the effect of the stylus tip size on the measuring error in surface topography measurement. To analyze the distortional effect of an actual surface geometry originating from the finite stylus size, the surface is modeled as a sinusoid and the stylus tip as a circle. the measuring error is defined as the ratio of the standard deviation of a tracing profile and an original profile. It is shown that this measuring error depends on the amplitude and wavelength of an original profile. In this paper, the spectrum analysis is applied to investigate the distortional effect due to the mechanical filtering of the stylus in the frequency domain. and, the cumulative power spectrum is applied to determinate the minimum wavelength limits to be measured with the various stylus tip radius from these results, a new method to select proper stylus tip radius is proposed.

  • PDF

표면거칠기 측정용 다이아몬드 촉침의 마모에 관한 연구 (A Study on the Wear of Diamond Stylus for Surface Roughness Measurement)

  • 한응교;노병옥;박두원;김종억
    • 한국정밀공학회지
    • /
    • 제8권3호
    • /
    • pp.105-113
    • /
    • 1991
  • The practicability of Ion-Sputter machining renders it possible to make diamond stylus for surface roughness measurement with micro stylus tip radius less than 2${\mu}mR$, and to measure surface roughness of fine-machined surface. In this study, we researched the wear or Ion-Sputtered stylus with 0.1${\mu}mR$ and 0.5${\mu}mR$ for micro-figure measurement and polished stylus with 0.5${\mu}mR$ according to measurement distance. As a result, we know that the case of Ion-Sputtered stylus is worn down easilier the case of polished stylus. And we know that in the evaluation of stylus wear, it is more useful method that examine the wear by measuring the variation of stylus tip radius than by evaluating the variation of Ra values.

  • PDF

촉침에 의한 표면 거칠기 측정 오차 해석 (Analysis of Measuring Error of Surface Roughness by Contact Stylus Profilometer)

  • 조남규;권기환
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.174-181
    • /
    • 1999
  • This paper describes the effect of the stylus tip size on the shape error in surface topography measurement. To analyze the distortional effect of an actual surface geometry origination from the finite stylus size, the surface is modeled as a sinusoid and the stylus tip as a circle. The magnitude of this distortion is defined as the ration of standard deviation, and this is expressed as an analytic function of the stylus tip radius and the geometrical parameter of a sinusoid. In this paper, the spectrum analysis of the profile is applied to investigate the distortional effect due to the mechanical filtering of the stylus in the frequency domain. and, the cumulative power spectrum is proposed to assess the shape error of measured data according to the various stylus tip sizes. From these results, a new method to select proper stylus tip radius is proposed.

  • PDF

이온스파터 가공한 다이아몬드 촉침의 선단반경이 표면거칠기 측정에 미치는 영향 (A Study on the Effect of Tip Radius of Diamond Stylus Machined by Ion Sputter in Surface Roughness Measurement)

  • 한응교;노병옥;유영덕
    • 한국정밀공학회지
    • /
    • 제7권3호
    • /
    • pp.37-47
    • /
    • 1990
  • In accordance with the high precision of mechanical elements, it has been required to high precision in surface roughness measurement and, therefore, stylus tip radius is manufa- ctured less than 2 .mu. m through ion sputter machining. In this experiment, by suing ion sputter machined stylus pf fine tip, radius and lapping machined stylus, surface roughness of standard specimens, silicon wafer were measured and then Rmax, Ra, RMS value were investi- gatedaccording to the variation of tip radius of stylus. As a result, measuring error due to the variation of stylus tip radius in surface roughness measurement was decreased by using ion sputter machined stylus and also the measuring accuracy was improved. And the measuring variation of Ra, RMS calculated from correlation coefficient lager than 0.9 on the wave of short period and amplitude using ion sputter machined stylus of fine tip radius.

  • PDF

촉침식표면거칠기 측정기에 있어서 촉침의 선단곡률반경과 측정압이 측정에 미치는 영향 (The Influence by Stylus Tip Radius and Measuring force on the Stylus Type Surface Roughness Tester)

  • 강명순;한응교;권동호;조남규
    • 한국정밀공학회지
    • /
    • 제3권1호
    • /
    • pp.69-76
    • /
    • 1986
  • The measuring Method by stylus, which measures surface roughness, has been widely used since G. Schmaltz developed the first equipment of that type. Withe the resent development of the measuring method by stylus, surface foughness testing instruments of the very high magnification ratio, hundreds of thousands, are manu- factured. However, as the techniques of the high precision roughness measurement are being required, the response problems due to the tip shapes and the plastic deformations of measured surface of mild material are to be serious factors. In this study, diamond stylus of tip radius $0.5\mu\textrm{m}$, $2\mu\textrm{m}$, $5\mu\textrm{m}$ and $10\mu\textrm{m}$ were used under the measuring force of 0.01gf, 0.02gf, 0.07gf, 0.4gf and 1.6gf, and from the experimental data, maximum measured value devrements between $2\mu\textrm{mR}$ stylus and $5\mu\textrm{mR}$ stylus, $2\mu\textrm{mR}$ stylus and $10\mu\textrm{mR}$ stylus are 22% and 31%, respectively when the measured value of $2\mu\textrm{mR}$ stylus goes to $0.01\mu\textrm{m Ra}$, $\lambda$ c2.5mm. And it is shown that plastic deformations on the plastic deformations on the measured surface are proportional to W/R(W;measured force, R;stylus tip radius).

  • PDF

Assessing the effect of stylus tip radius on surface roughness measurement by accumulation spectral analysis

  • Kwon Ki-Hwan;Cho Nahm-Gyoo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권1호
    • /
    • pp.9-12
    • /
    • 2006
  • A spectral analysis and numerical simulation are employed to assess the effects of the stylus tip radius on measuring surface profiles. Original profiles with fractal spectral densities are generated and then are numerically traced with circular tipped stylus. Instead of their spectral densities, the accumulative power spectrums of traced profiles are analyzed. It is shown that the minimum wavelength of traced profile relates directly to the radius r of the stylus tip and the root-mean-square (rms) roughness ${\sigma}_o$ of original profile. From this accumulation spectral analysis, a formula is developed to estimate the minimum wavelength of traced profile. By using the concept of the minimum wavelength, an appropriate stylus tip radius can be chosen for the given rms roughness ${\sigma}_o$ of the profile.

Roughness Measurement Performance Obtained with Optical Interferometry and Stylus Method

  • Rhee Hyug-Gyo;Lee Yun-Woo;Lee In-Won;Vorburger Theodore V.
    • Journal of the Optical Society of Korea
    • /
    • 제10권1호
    • /
    • pp.48-54
    • /
    • 2006
  • White-light scanning interferometry (WLI) and phase shifting interferometry (PSI) are increasingly used for surface topography measurements, particularly for areal measurements. In this paper, we compare surface profiling results obtained from above two optical methods with those obtained from stylus instruments. For moderately rough surfaces ($Ra{\approx}500\;nm$), roughness measurements obtained with WLI and the stylus method seem to provide close agreement on the same roughness samples. For surface roughness measurements in the 50 nm to 300 nm range of Ra, discrepancies between WLI and the stylus method are observed. In some cases the discrepancy is as large as 109% of the value obtained with the stylus method. By contrast, the PSI results are in good agreement with those of the stylus technique.

정전용량방식 터치패널용 스타일러스펜의 정전특성 연구 (A Study on Capacitance Properties of Stylus Pen Applied to Capacitive Touch Panel)

  • 이재윤;유시홍;성민호;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제25권8호
    • /
    • pp.651-656
    • /
    • 2012
  • A study on capacitive characteristics of stylus pen for touch panel are progressed in this paper. Also the main factors for capacitive sensitivity are studied. Namely, highly sensitive stylus pen which can be applied to capacitive touch panel are studied based on the analysis of materials and process conditions regardless of pattern shapes. Stylus pen was made of PDMS(Poly-Di-Methyl-Siloxane) and conductive metal powders which does not damage the touch panel surface. We tried to get the advantages of both the properties of soft PDMS and conductive metal powders. We found that potential difference of capacitance change with conductivity of the composite materials(PDMS + metal powders) it implies that during touch process, large voltage difference can be caused by the high conductive materials of stylus pen. Stylus pen made by PDMS with mixed with Ag powders which has large conductivity shows more capacitance change of 1 pF than PDMS with other materials of Ni or C powders.

다이아몬드 촉침의 이온 스파터 가공조건에 관한 연구 (A study on the machining condition of diamond stylus using ion sputter machining)

  • 한응교;노병옥;김병우
    • 대한기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.1495-1508
    • /
    • 1990
  • 본 연구에서는 전류밀도와 가공시간을 변화시켰을 때의 가공량, 가공상태를 검토해 보았으며, 촉침홀더의 가공각도를 달리하거나 재부착문제를 해결하기 위한 마 스크의 사용여부에 따른 촉침의 가공상태를 알아보기 위해 초기선단반경 2$\mu\textrm{m}$, 선단각 90˚의 다이아몬드 촉침을 이온스파터 가공기를 사용하고, 가공조건을 변화시켜서 초 정밀 가공품의 표면거칠기 측정에 적합한 0.5$\mu\textrm{m}$ 이하의 미세한 선단반경을 갖는 촉침 을 가공하기 위한 가공조건에 대한 실험을 하였다.

Development of Prototype Stylus Prototype for Large Optics Testing

  • Yang, Ho-Soon;Walker, David
    • Journal of the Optical Society of Korea
    • /
    • 제5권2호
    • /
    • pp.60-66
    • /
    • 2001
  • The authors discuss a prototype stylus profilometer designed to measure large optics. It consists of a low contact force type probe system, laser reference system, interferometric distance measurement system, and horizontal driving system. The probe contacts the surface ; the height and the horizontal distances of the measurement points are measured by the interferometer. The freely propagated laser beam provides the reference line during the measurement. The developed stylus profilometry shows only $\pm$60 nm of P-V error for the 157 mm diameter spherical mirror.