• 제목/요약/키워드: stub column test

검색결과 50건 처리시간 0.018초

Post-fire test of precast steel reinforced concrete stub columns under eccentric compression

  • Yang, Yong;Xue, Yicong;Yu, Yunlong;Gong, Zhichao
    • Steel and Composite Structures
    • /
    • 제33권1호
    • /
    • pp.111-122
    • /
    • 2019
  • This paper presents an experimental work on the post-fire behavior of two kinds of innovative composite stub columns under eccentric compression. The partially precast steel reinforced concrete (PPSRC) column is composed of a precast outer-part cast using steel fiber reinforced reactive powder concrete (RPC) and a cast-in-place inner-part cast using conventional concrete. Based on the PPSRC column, the hollow precast steel reinforced concrete (HPSRC) column has a hollow column core. With the aim to investigate the post-fire performance of these composite columns, six stub column specimens, including three HPSRC stub columns and three PPSRC stub columns, were exposed to the ISO834 standard fire. Then, the cooling specimens and a control specimen unexposed to fire were eccentrically loaded to explore the residual capacity. The test parameters include the section shape, concrete strength of inner-part, eccentricity ratio and heating time. The test results indicated that the precast RPC shell could effectively confine the steel shape and longitudinal reinforcements after fire, and the PPSRC stub columns experienced lower core temperature in fire and exhibited higher post-fire residual strength as compared with the HPSRC stub columns due to the insulating effect of core concrete. The residual capacity increased with the increasing of inner concrete strength and with the decreasing of heating time and load eccentricity. Based on the test results, a FEA model was established to simulate the temperature field of test specimens, and the predicted results agreed well with the test results.

Mechanical performance of sand-lightweight concrete-filled steel tube stub column under axial compression

  • Zhang, Xianggang;Deng, Dapeng;Lin, Xinyan;Yang, Jianhui;Fu, Lei
    • Structural Engineering and Mechanics
    • /
    • 제69권6호
    • /
    • pp.627-635
    • /
    • 2019
  • In order to study the axial compression performance of sand-lightweight concrete-filled steel tube (SLCFST) stub columns, three circular SLCFST (C-SLCFST) stub column specimens and three SLCFST square (S-SLCFST) stub column specimens were fabricated and static monotonic axial compression performance testing was carried out, using the volume ratio between river sand and ceramic sand in sand-lightweight concrete (SLC) as a varying parameter. The stress process and failure mode of the specimens were observed, stress-strain curves were obtained and analysed for the specimens, and the ultimate bearing capacity of SLCFST stub column specimens was calculated based on unified strength theory, limit equilibrium theory and superposition theory. The results show that the outer steel tubes of SLCFST stub columns buckled outward, core SLC was crushed, and the damage to the upper parts of the S-SLCFST stub columns was more serious than for C-SLCFST stub columns. Three stages can be identified in the stress-strain curves of SLCFST stub columns: an elastic stage, an elastic-plastic stage and a plastic stage. It is suggested that AIJ-1997, CECS 159:2004 or AIJ-1997, based on superposition theory, can be used to design the ultimate bearing capacity under axial compression for C-SLCFST and S-SLCFST stub columns; for varying replacement ratios of natural river sand, the calculated stress-strain curves for SLCFST stub columns under axial compression show good fitting to the test measure curves.

Mechanical behaviour of concrete filled double skin steel tubular stub columns confined by FRP under axial compression

  • Wang, Jun;Liu, Weiqing;Zhou, Ding;Zhu, Lu;Fang, Hai
    • Steel and Composite Structures
    • /
    • 제17권4호
    • /
    • pp.431-452
    • /
    • 2014
  • The present study focuses on the mechanical behaviour of concrete filled double skin steel tubular (CFDST) stub columns confined by fiber reinforced polymer (FRP). A series of axial compression tests have been conducted on two CFDST stub columns, eight CFDST stub columns confined by FRP and a concrete-filled steel tubular (CFST) stub column confined by FRP, respectively. The influences of hollow section ratio, FRP wall thickness and fibre longitudinal-circumferential proportion on the load-strain curve and the concrete stress-strain curve for stub columns with annular section were discussed. The test results displayed that the FRP jacket can obviously enhance the carrying capacity of stub columns. Based on the test results, a new model which includes the effects of confinement factor, hollow section ratio and lateral confining pressure of the outer steel tube was proposed to calculate the compressive strength of confined concrete. Using the present concrete strength model, the formula to predict the carrying capacity of CFDST stub columns confined by FRP was derived. The theoretically predicted results agree well with those obtained from the experiments and FE analysis. The present method is also adapted to calculate the carrying capacity of CFST stub columns confined by FRP.

SS400 강재를 사용한 개량 T-stub 반강접합부의 역학적 거동 (The Structural Behavior of Semi-Rigid Connections with Reformed T-stub by Using of SS400 Steel)

  • 이명재;양명숙;조원혁
    • 한국강구조학회 논문집
    • /
    • 제11권2호통권39호
    • /
    • pp.241-241
    • /
    • 1999
  • 강구조 건축물의 해석과 설계는 기둥-보 접합부가 완전강접이나 핀접합이라는 가정하에 일반적으로 이루어진다. 그러나 실제로는 많은 경우의 접합부형태들이 반강접합의 거동을 보이고 있다. 필자 등은 개량 T-stub로서 SM490강재를 이용하여 반강접합부의 거동을 조사한 바 있다. 본 연구의 목적은 SS400강재로 된 개량 T-stub를 이용한 기둥-보 반강접합부의 구조적 거동을 조사하기 위한 것이다. 연구방법으로서 개량 T-stub요소의 인장, 압축실험과 해석 및 개량 T-stub를 이용한 기둥-보 접합부의 단조가력 및 반복가력실험을 실시하였다. 본 연구의 실험결과로부터 개량 T-stub를 이용한 반강접합부의 적용가능성이 확인되었다.

  • PDF

Axial compression performance of basalt-fiber-reinforced recycled-concrete-filled square steel tubular stub column

  • Zhang, Xianggang;Gao, Xiang;Wang, Xingguo;Meng, Ercong;Wang, Fang
    • Advances in concrete construction
    • /
    • 제10권6호
    • /
    • pp.559-571
    • /
    • 2020
  • This study aimed to inspect the axial compression mechanical performance of basalt-fiber-reinforced recycled - concrete (BFRRC)-filled square steel tubular stub column. The replacement ratio of recycled coarse aggregate (RCA) and the basalt fiber (BF) dosage were used as variation parameters, and the axial compression performance tests of 15 BFRRC-filled square steel tubular stub column specimens were conducted. The failure mode and the load-displacement/strain curve of the specimen were measured. The working process of the BFRRC-filled square steel tubular stub column was divided into three stages, namely, elastic-elastoplasticity, sudden drawdown, and plasticity. The influence of the design parameters on the peak bearing capacity, energy dissipation performance, and other axial compression performance indexes was discussed. A mathematical model of segmental stiffness degradation was proposed on the basis of the degradation law of combined secant-stiffness under axial compression. The full-process curve equation of axial compressive stress-strain was proposed by introducing the influencing factors, including the RCA replacement ratio and the BF dosage, and the calculated curve agreed well with the test-measured curve.

비재하 가열시험 및 Stub 시험체를 활용한 CFT기둥의 역학적 특성평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Mechanical Properties of CFT Column by Unstressed Test and Stub Specimen)

  • 이대희;이태규;이의배;김영선;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.209-213
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) because material and method are required to be diversification and High-Performance according to increase the super-high structure. But, CFT column lose bearing capacity under fire because steel tube is exposed to outside. As a result, structure is collapsed and then it cause much damage. In case of the Europe, Japan and America, they have studied the fire-resistance performance of CFT under fire for a long time. However, it would have hardly studied it in domestic because it is much difficulty about experiment machine and cost. So it is needed base on fire-resist performance of CFT under fire. Therefore, this study dynamic specificity of stub column which made tester of stub column based on facts of strength and mixing fiber evaluated used heating and load testing machine. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF

중심압축력을 받는 일반구조용 강관의 구조성능에 관한 연구 (A Study on the Structural Property of Structural Steel Tubes under Axial Compression)

  • 김종락;이은택;이소연;백기열
    • 한국강구조학회 논문집
    • /
    • 제20권3호
    • /
    • pp.437-444
    • /
    • 2008
  • 현재 국내에 유통되고 있는 강관은 국내산과 수입산이 혼용되고 있으며, 수입산 강관은 가격경쟁 면에서 그 수요가 꾸준히 증가하고 있다. 본 연구는 국내에 유통되고 있는 일반구조용 원형강관 및 비계용 강관에 대하여 소재의 인장시험과 Stub -column 압축시험 및 기둥의 좌굴실험을 통하여 일반구조용 강관의 기계적 성질과 기둥의 강도 및 거동을 파악하고자 한다. 또한 한계상태설계법의 기준식과 복수강도곡선의 적용으로 이론값과 실험값을 비교하여 기계적 요구 성능 및 적합성 여부를 조사하고, 설계기준에 대한 기초자료를 확보하고자 한다. 단주압축 실험결과 관경두께비를 만족하는 시험체의 경우에는 최대내력에 도달한 후 서서히 내력이 저하되는 결과를 나타내었다. 기둥좌굴 실험결과, 최대내력은 일정한 좌굴내력 범위를 나타내었으며 전반적으로 한계상태설계법의 기준곡선에 만족하는 결과를 나타내었다.

Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns

  • Han, Lin-Hai;Zhao, Xiao-Ling;Tao, Zhong
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.51-74
    • /
    • 2001
  • A series of tests on concrete-filled SHS (Square Hollow Section) stub columns (twenty), columns (eight) and beam-columns (twenty one) were carried out. The main parameters varied in the tests are (1) Confinement factor (${\xi}$) from 1.08 to 5.64, (2) concrete compression strength from 10.7MPa to 36.6MPa, (3) tube width to thickness ratio from 20.5 to 36.5. (4) load eccentricity (e) from 15 mm to 80 mm and (5) column slenderness (${\lambda}$) from 45 to 75. A mechanics model is developed in this paper for concrete-filled SHS stub columns, columns and beam-columns. A unified theory is described where a confinement factor (${\xi}$) is introduced to describe the composite action between the steel tube and filled concrete. The predicted load versus axial strain relationship is in good agreement with stub column test results. Simplified models are derived for section capacities and modulus in different stages of the composite sections. The predicted beam-column strength is compared with that of 331 beam-column tests with a wide range of parameters. A good agreement is obtained. The predicted load versus midspan deflection relationship for beam-columns is in good agreement with test results. A simplified model is developed for calculating the member capacity of concrete-filled SHS columns. Comparisons are made with predicted columns strengths using the existing codes such as LRFD (AISC 1994), AIJ (1997), and EC4 (1996). Simplified interaction curves are derived for concrete-filled beam-columns.

실험 및 데이터 분석에 의한 CFCT 단주 특성 (Characteristics of Concrete Filled Circular Tubular Stub Columns based on Experiment and Data Analysis)

  • 강현식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.161-168
    • /
    • 2001
  • The use of composite members to improve the compressive strength of steel structure is a common practice these days and its efficiency has already been proved by several researches and experiments. The result of concrete filled circular tubular(CFCT) stub column tests is introduced in this paper. The main parameter of this test is the ratio of diameter to thickness of circular hollow section. From the test results, the effect of concrete filled in steel tube on the ultimate strength, the deformation capacity and initial stiffness are discussed. The purpose of this paper is to investigate the effect of various parameters and evaluate the compressive strength of confined concrete. It would contribute to a better understanding of CFT structure, further laboratory experimentations are needed for better accurate estimation on its effect.

  • PDF

공간구조에 적용되는 일반구조용 강관의 압축내력에 관한 연구 (A Study on the Compression Strength of Structural Steel Tube Applied in Spatial Structure)

  • 백기열
    • 한국공간구조학회논문집
    • /
    • 제8권5호
    • /
    • pp.83-93
    • /
    • 2008
  • 국민소득수준의 향상에 따라 국내 건축물의 디자인 및 사용목적의 대한 다양성이 요구되고 있다. 대공간 구조물은 이러한 시대적 요구에 적합한 구조물로서 최근 대공간 구조물에 대한 설계 및 시공법에 관한 관심이 꾸준히 증가하고 있다. 트러스구조는 대공간 구조에 보편적으로 사용되는 구조시스템으로 트러스의 부재는 단면의 효율이 높은 강관을 사용하는 것이 일반적이다. 현재 국내에 유통되고 있는 강관은 생산처에 따라 다양한 제품이 생산되고 있으나 강관 소재의 출처 및 강관 자체의 실제 성능에 관한 연구는 미비한 실정이다. 이 연구는 국내에 유통되고 있는 일반구조용 각형강관, 원형강관 및 비계용 강관에 대하여 소재의 인장시험과 Stub-column 압축시험 및 기둥의 좌굴실험을 통해 강관의 소재성능 및 구조부재로서의 압축성능을 파악하는 것을 목적으로 한다. 소재시험결과, 구입처 구분 및 단면형상에 따른 강관 소재성능의 편차가 확인되었다. 기둥좌굴 실험결과, 각 실험체의 압축내력은 LSD 기준곡선에 만족하는 결과를 나타내었으며, SSRC 곡선1, ECCS-a곡선에 상회하는 결과를 나타내었다.

  • PDF