• Title/Summary/Keyword: structure detection

Search Result 2,014, Processing Time 0.032 seconds

An Improved Nonparametric Change Detection Algorithm Using Euler Number and Structure Tensor (오일러 수와 구조 텐서를 사용한 개선된 Nonparametric 변화 검출 알고리즘)

  • 이웅희;김태희;정동석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10C
    • /
    • pp.958-966
    • /
    • 2003
  • Change detection algorithms based on frame difference are frequently used for finding moving objects in image sequences. These algorithms detect the change of frames using estimated statistical background model. But, if this estimated background model is different from the actual statistical distribution, false detections are generated. In this paper, we propose an improved change detection algorithm using euler number and structure tensor. The proposed mapping method which is based on the euler number can be used for reducing the false detections that generated by nonparametric change detection algorithm. In this paper, the change in the region of moving object also can be detected by the proposed method using structure tensor. Experimental result shows that the proposed method reduces the false detections effectively by 90% on "Weather", by 34% on "Mother & daughter" and by 43% on "Aisle" than an existing method does.

Vision-based technique for bolt-loosening detection in wind turbine tower

  • Park, Jae-Hyung;Huynh, Thanh-Canh;Choi, Sang-Hoon;Kim, Jeong-Tae
    • Wind and Structures
    • /
    • v.21 no.6
    • /
    • pp.709-726
    • /
    • 2015
  • In this study, a novel vision-based bolt-loosening monitoring technique is proposed for bolted joints connecting tubular steel segments of the wind turbine tower (WTT) structure. Firstly, a bolt-loosening detection algorithm based on image processing techniques is developed. The algorithm consists of five steps: image acquisition, segmentation of each nut, line detection of each nut, nut angle estimation, and bolt-loosening detection. Secondly, experimental tests are conducted on a lab-scale bolted joint model under various bolt-loosening scenarios. The bolted joint model, which is consisted of a ring flange and 32 sets of bolt and nut, is used for simulating the real bolted joint connecting steel tower segments in the WTT. Finally, the feasibility of the proposed vision-based technique is evaluated by bolt-loosening monitoring in the lab-scale bolted joint model.

Damage detection in jacket type offshore platforms using modal strain energy

  • Asgarian, B.;Amiri, M.;Ghafooripour, A.
    • Structural Engineering and Mechanics
    • /
    • v.33 no.3
    • /
    • pp.325-337
    • /
    • 2009
  • Structural damage detection, damage localization and severity estimation of jacket platforms, based on calculating modal strain energy is presented in this paper. In the structure, damage often causes a loss of stiffness in some elements, so modal parameters; mode shapes and natural frequencies, in the damaged structure are different from the undamaged state. Geometrical location of damage is detected by computing modal strain energy change ratio (MSECR) for each structural element, which elements with higher MSECR are suspected to be damaged. For each suspected damaged element, by computing cross-modal strain energy (CMSE), damage severity as the stiffness reduction factor -that represented the ratios between the element stiffness changes to the undamaged element stiffness- is estimated. Numerical studies are demonstrated for a three dimensional, single bay, four stories frame of the existing jacket platform, based on the synthetic data that generated from finite element model. It is observed that this method can be used for damage detection of this kind of structures.

Rotor Initial Polarity Detection Method of Single-Phase PMSM Considering Asymmetric Air-Gap Structure (단상 영구자석 동기 전동기의 비대칭 공극 구조를 고려한 회전자 초기 자극 검출 기법)

  • Seo, Sung-Woo;Hwang, Seon-Hwan;Park, Jong-Won;Kim, Yong-Hyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.1
    • /
    • pp.80-83
    • /
    • 2022
  • This paper proposes an initial rotor polarity detection algorithm of a single-phase permanent magnet synchronous motor (SP-PMSM) related to stable open-loop starting for sensorless operation. Generally, the SP-PMSM needs an asymmetric air-gap structure to can avoid the initial starting failure at zero torque point. Therefore, the rotor polarity information can be obtained by using the DC offset current direction of a stator current through a high frequency voltage injection into an SP-PMSM with an asymmetric air gap. In this paper, the proposed rotor initial polarity detection algorithm is verified through several experimental results.

A Study for The Comparison of Structural Damage Detection Method Using Structural Dynamic Characteristic Parameters (구조 동특성 파라미터를 이용한 구조물 손상 탐색기법 비교 연구)

  • Choi, Byoung-Min;Woo, Ho-Kil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.257-263
    • /
    • 2007
  • Detection of structural damage is an inverse problem in structural engineering. There are three main questions in the damage detection: existence, location and extent of the damage. In concept, the natural frequency and mode shapes of any structure must satisfy an eigenvalue problem. But, if a potential damage exists in a structure, an error resulting from the substitution of the refined analytical finite element model and measured modal data into the structural eigenvalue equation will occur, which is called the residual modal forces, and can be used as an indicator of potential damage in a structure. In this study, a useful damage detection method is proposed and compared with other two methods. Two degree-of-freedom system and Cantilever beam are used to demonstrate the approach. And the results of three introduced method are compared.

LDO Regulator with Improved Fast Response Characteristics and Push-Pull Detection Structure (Push-Pull Detection 구조 및 빠른 응답 특성을 갖는 LDO 레귤레이터)

  • Lee, Joo-Young
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.201-205
    • /
    • 2021
  • In this paper present Low Drop-Out (LDO) regulator that improved load transient characteristics due to the push-pull detection structure. The response characteristic of the voltage delta value is improved due to the proposed push-pull sensing circuit structure between the input terminal of the LDO regulator pass transistor and the output terminal of the internal error amplifier. Voltage value has improved load transient characteristics than conventional LDO regulator. Compared to the conventional LDO regulator, it has an improved response speed of approximately 244 ns at rising time and approximately 90 ns at falling time. The proposed circuit was simulated by the samsung 0.13um process using Cadence's Specter and Virtuoso simulator.

Structural Health Monitoring of Harbor Caisson-type Structures using Harmony Search Method (최적화 화음탐색법을 이용한 항만 케이슨 구조물의 구조건전성 평가)

  • Lee, So-Young;Kim, Jeong-Tae;Yi, Jin-Hak;Kang, Yoon-Koo
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.122-128
    • /
    • 2009
  • In this study, damage detection method using harmony search method and frequency response is proposed. In order to verify this method, the following approaches are implemented. Firstly, damage detection method using harmony search was developed. To detect damage, objective functions that minimize difference with natural frequency and modal strain energy from undamaged and damaged model are used. Secondly, efficiency of developed damage detection method was verified by damage detection of beam structure. And results of harmony search and micro genetic algorithm are compared and evaluated. Thirdly, numerical model was implemented for harbor caisson structure and damage scenario was determined. Lastly, damage detection was performed by proposed method and utility of proposed method is verified.

Hybrid bolt-loosening detection in wind turbine tower structures by vibration and impedance responses

  • Nguyen, Tuan-Cuong;Huynh, Thanh-Canh;Yi, Jin-Hak;Kim, Jeong-Tae
    • Wind and Structures
    • /
    • v.24 no.4
    • /
    • pp.385-403
    • /
    • 2017
  • In recent years, the wind energy has played an increasingly important role in national energy sector of many countries. To harvest more electric power, the wind turbine (WT) tower structure becomes physically larger, which may cause more risks during long-term operation. Associated with the great development of WT projects, the number of accidents related to large-scaled WT has also been increased. Therefore, a structural health monitoring (SHM) system for WT structures is needed to ensure their safety and serviceability during operational time. The objective of this study is to develop a hybrid damage detection method for WT tower structures by measuring vibration and impedance responses. To achieve the objective, the following approaches are implemented. Firstly, a hybrid damage detection scheme which combines vibration-based and impedance-based methods is proposed as a sequential process in three stages. Secondly, a series of vibration and impedance tests are conducted on a lab-scaled model of the WT structure in which a set of bolt-loosening cases is simulated for the segmental joints. Finally, the feasibility of the proposed hybrid damage detection method is experimentally evaluated via its performance during the damage detection process in the tested model.

Real time crack detection using mountable comparative vacuum monitoring sensors

  • Roach, D.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.317-328
    • /
    • 2009
  • Current maintenance operations and integrity checks on a wide array of structures require personnel entry into normally-inaccessible or hazardous areas to perform necessary nondestructive inspections. To gain access for these inspections, structure must be disassembled and removed or personnel must be transported to remote locations. The use of in-situ sensors, coupled with remote interrogation, can be employed to overcome a myriad of inspection impediments stemming from accessibility limitations, complex geometries, the location and depth of hidden damage, and the isolated location of the structure. Furthermore, prevention of unexpected flaw growth and structural failure could be improved if on-board health monitoring systems were used to more regularly assess structural integrity. A research program has been completed to develop and validate Comparative Vacuum Monitoring (CVM) Sensors for surface crack detection. Statistical methods using one-sided tolerance intervals were employed to derive Probability of Detection (POD) levels for a wide array of application scenarios. Multi-year field tests were also conducted to study the deployment and long-term operation of CVM sensors on aircraft. This paper presents the quantitative crack detection capabilities of the CVM sensor, its performance in actual flight environments, and the prospects for structural health monitoring applications on aircraft and other civil structures.

Air Flow Sensor with Corrugation Structure for Low Air Velocity Detection (주름구조를 적용한 저속 유속 센서)

  • Choi, Dae-Keun;Lee, Sang-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.393-399
    • /
    • 2011
  • In this paper, we designed and fabricated the novel air flow sensor using air drag force, which can be applied to the low air flow detection. To measure the low air flow, we should enlarge the air drag force and the output signal at the given air flow. The paddle structure is applied to the device, and the device is vertically located against the air flow to magnify the air drag force. We also adapt the corrugation structure to improve the output signals on the given air velocity. The device structure is made up of the silicon nitride layer and the output signal is measured with the piezoresistive layer. The output signals from the corrugated device show the better measurement sensitivity and the response time than that of flat one. The repeated measurement also shows the stabilized signals.