Assessment of ASCE 7-10 for wind effects on low-rise wood frame buildings with database-assisted design methodology

  • He, Jing;Pan, Fang;Cai, C.S.
    • Wind and Structures
    • /
    • 제27권3호
    • /
    • pp.163-173
    • /
    • 2018
  • The design wind pressure for low-rise buildings in the ASCE 7-10 is defined by procedures that are categorized into the Main Wind Force-Resisting System (MWFRS) and the Components and Cladding (C&C). Some of these procedures were originally developed based on steel portal frames of industrial buildings, while the residential structures are a completely different structural system, most of which are designed as low-rise light-frame wood constructions. The purpose of this study is to discuss the rationality (or irrationality) of the extension of the wind loads calculated by the ASCE 7-10 to the light-frame wood residential buildings that represent the most vulnerable structures under extreme wind conditions. To serve this purpose, the same approach as used in the development of Chapter 28 of the ASCE 7-10 that envelops peak responses is adopted in the present study. Database-assisted design (DAD) methodology is used by applying the dynamic wind loads from Louisiana State University (LSU) database on a typical residential building model to assess the applicability of the standard by comparing the induced responses. Rather than the postulated critical member demands on the industrial building such as the bending moments at the knee, the maximum values at the critical points for wood frame buildings under wind loads are used as indicators for the comparison. Then, the critical members are identified through these indicators in terms of the displacement or the uplift force at connections and roof envelope. As a result, some situations for each of the ASCE 7 procedures yielding unconservative wind loads on the typical low-rise residential building are identified.

오에스비에 대한 각종 부재의 못전단성능 (Nail Shear Performance of Structural Members with OSB)

  • 황권환;박문재
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권4호
    • /
    • pp.66-76
    • /
    • 2008
  • 최근 국내에서 급격히 그 수요가 증가하고 있는 낙엽송과 북미산 SPF(spruce-pine-fir) 규격재의 구조부재로서의 이용에 있어서 가장 간단하면서 많이 이용되는 파스너(fastener)인 못을 이용한 접합에 대해 그 전단성능을 검토하였다. 못접합은 특히 경골목구조(light frame construction)에서는 최적의 시공법으로 인식되고 있으며, 북미와 일본을 중심으로 못접합부에 대한 연구는 많이 진행되어 왔다. 현재 국내의 경골목구조와 기둥-보 공법에서 많이 이용되고 있는 구조부재(축재와 면재)의 못을 이용한 못접합부에 대해 그 전단성능의 기초적인 검토를 행하였다. 못접합부는 면재를 개입한 상태에서 주부재와 측면부재의 방향성에 따라 구분하여 주부재의 방향, 측면부재의 방향, 못의 종류에 따라 전단시험을 행하여 각각의 방향에 따른 못접합부의 전단성능을 비교 검토하였다. SPF 스터드재에 있어서는 낙엽송 집성재나 낙엽송 소재에 비해 못의 종류, 주부재와 면재의 방향성에 따른 전단성능의 차이가 현저하게 나타났다. 또한, 항복내력 및 최대내력과 접합계수와의 관계는 부재간의 배치상태에 따라 다르게 나타났다.

목재를 이용한 육각형 공간 트러스 모델의 정적좌굴하중 특성 (Characteristics of Static Buckling Load of the Hexagonal Spatial Truss Models using Timber)

  • 하현주;손수덕;이승재
    • 한국공간구조학회논문집
    • /
    • 제22권3호
    • /
    • pp.25-32
    • /
    • 2022
  • In this paper, the instability of the domed spatial truss structure using wood and the characteristics of the buckling critical load were studied. Hexagonal space truss was adopted as the model to be analyzed, and two boundary conditions were considered. In the first case, the deformation of the inclined member is only considered, and in the second case, the deformation of the horizontal member is also considered. The materials of the model adopted in this paper are steel and timbers, and the considered timbers are spruce, pine, and larch. Here, the inelastic properties of the material are not considered. The instability of the target structure was observed through non-linear incremental analysis, and the buckling critical load was calculated through the singularities and eigenvalues of the tangential stiffness matrix at each incremental step. From the analysis results, in the example of the boundary condition considering only the inclined member, the critical buckling load was lower when using timber than when using steel, and the critical buckling load was determined according to the modulus of elasticity of timber. In the case of boundary conditions considering the effect of the horizontal member, using a mixture of steel and timber case had a lower buckling critical load than the steel case. But, the result showed that it was more effective in structural stability than only timber was used.

류금두공의 양식적 형성과정 연구 (A Study on the Style Emergence of Liujin Dougong)

  • 백소훈
    • 건축역사연구
    • /
    • 제26권3호
    • /
    • pp.19-30
    • /
    • 2017
  • This paper studies the style emergence of Liujin Dougong in the ancient Chinese architecture. Dougong is the bracket set of the ancient Chinese wood structural architecture, and Liujin Dougong is one of the late styles of Chinese Dougong. It emerged in the period of the Ming Dynasty and has been installed in imperial palaces and imperial temples till the late period of the Qing Dynasty. Through the long term field survey and documental investigation, this research found out the some prototypes of Liujin Dougong among the earlier Xia-ang style Dougongs in the Song and Yuan Dynasty architectures. The symptom of style change appeared in the bracket composition. In the beginning, because Shuatou, the horizontal member just on Xia-ang was needed to be fixed to the inner main structure system, it was changed to the diagonal member and replaced Xia-ang. It brought continuous changes, the other horizontal members of Dougong also began to change to the diagonal form. And in accordance with these compositional changes of Dougong members, the decoration of inner parts also began to change. This paper analyzed every step of the compositional and decorative changes from Xia-ang Dougong style to Liujin Dougong style. In the addition, it also proposed the typical model of Qing style Liujin Dougong of which tail end is not placed on the beam and is just placed under the purlin, based on the its own research and analysis.

포스트텐션 전이슬래브의 구조해석 및 설계방법 (Structural Analysis and Design of Post-Tension Transfer Slab)

  • 윤장근;강수민;김욱종;이도범;추문석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.19-20
    • /
    • 2010
  • 본 연구는 전이슬래브의 두께를 줄이고 철근량을 감소시키기 위해 포스트텐션을 전이슬래브에 적용하는 포스트텐션 전이슬래브에 관한 연구이다. 본 논문에서는 전이슬래브와 같이 두꺼운 판요소 해석에 적합한 Wood-Armer 공식과 부착 긴장재를 사용한 포스트텐션 설계방법을 제안하고자 한다.

  • PDF

낙엽송 블록접착집성재의 접착 및 휨 강도 성능 (Bending and Bonding Strength Performances of Larix Block-glued Glulam)

  • 이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권3호
    • /
    • pp.315-322
    • /
    • 2016
  • 2개 이상의 보부재 집성재 요소들의 측면접착으로 제작된 "블록접착집성재"는 대단면 목조건축물의 건축부재로 활용 가능한 구조용재다. 블록접착집성재의 측면은 접착제의 종류와 도포량 및 압체압력을 각기 다른 조합으로 접착하여 박리시험과 전단블록시험으로 접착성능을 검토하였다. 실험결과 레조시놀접착제 $500g/m^2$을 도포하고 압체압력 1.5 MPa의 조건으로 제작된 블록접착집성재의 측면접착성능이 가장 양호하였다. 양호한 측면접착조건으로 제작된 블록접착집성재는 동일단면계수의 대조군 집성재와 휨 강도 성능을 비교 검토하였다. 블록접착집성재의 휨 탄성계수는 대조군 집성재와 유사하였으며, 파괴계수는 대조군집성재 보다 27% 향상되었다. 할렬은 대조군집성재 보다 블록접착집성재에서 다량 발생하였으며, 블록접착집성재의 측면접착층에서 계면파괴나 응집파괴는 관찰되지 않았다.

GFRP 보강적층판 및 GFRP rod를 이용한 낙엽송 집성재 접합부의 모멘트저항 성능평가 (Moment Resistance Performance Evaluation of Larch Glulam Joints using GFRP-reinforced Laminated Plate and GFRP Rod)

  • 정홍주;송요진;이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.40-47
    • /
    • 2016
  • 구조용 집성재 라멘 접합부에 일반적으로 사용되는 접합철물을 대신하여 단판과 GFRP (Glass Fiber Reinforced Plastic)를 복합시킨 GFRP 보강적층판과 삽입 접착형 GFRP rod를 접합물로 사용하였다. 이들을 적용시킨 접합부에 대한 모멘트저항 성능평가 결과, 접합철물을 이용한 실험체(Type-1)와 비교하여 GFRP 보강적층판과 GFRP rod 핀을 사용한 실험체의 항복모멘트는 4% 낮게 측정되었으나 회전강성은 29% 높게 측정되었다. 또한 GFRP 보강적층판과 목재(Eucalyptus marginata)핀을 사용한 실험체는 Type-1 실험체와 비교하여 항복모멘트 11%, 회전강성 56% 높게 측정되며 가장 양호한 성능을 나타냈었다. 파괴형상과 완전탄소성 분석을 통해서도 핀에 의한 전단내력으로부터의 취성파괴가 아닌 연성거동을 나타내며, 접합내력이 상승하고 부재의 일체화가 이루어짐을 확인하였다. 반면, GFRP rod를 삽입 접착한 실험체는 접착 불량으로 측정이 불가하거나 접합성능이 매우 낮게 측정되었다.

백합나무 스킨팀버의 압축 성능에 관한 연구 (A Study on the Compressive Capacity of Yellow Poplar Skin-timber)

  • 김광철
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권4호
    • /
    • pp.333-343
    • /
    • 2011
  • 백합나무(yellow poplar)는 기후변화의 주범인 이산화탄소의 흡수율이 매우 뛰어나고 오존흡수율도 뛰어나 저탄소 녹생성장 시대에 적합한 수종이다. 속성수인 백합나무는 구조용 부재로의 성능은 약간 부족하지만 가구재나 내장재, 합판용재 등 다양한 용도로 활용가능한 수종이다. 본 연구에서는 백합나무를 이용하여 대단면 스킨팀버를 개발하고 압축 성능을 평가하였으며 다양한 용도 개발을 위해 수치해석 모델을 개발하였다. 정각형 스킨팀버는 소재에 대해 56.3%의 잔존 강도를 보여서 우수한 성능을 나타내었으며 원통형 스킨팀버의 경우 잔존면적율이 25%임에도 불구하고 소재에 대해 50% 가까운 압축 성능을 나타내어 가구용 뿐만 아니라 대단면 재료로써 다양한 쓰임새가 가능함을 보여주었다. 정각형과 원통형 모두 Brooming or end rolling이 주요 파괴모드로 나타났으며 부분적으로 splitting 파괴 모드도 나타났다. 잔존면적률이 큰 정각형 스킨팀버의 압축성능이 원통형 스킨팀버보다 높게 나타났지만 두 집단간에 압축성능에 있어 통계적 유의성은 보이지 않아 사용자의 편의대로 혼용하여 활용 가능할 것으로 판단된다. 수치해석 모델은 실제 압축성능 실험과 상당히 유사한 결과를 보였다. 따라서 다양한 형태와 치수에 대한 수치해석 모델 적용을 통해 백합나무 스킨팀버의 다양한 용도 개발에 활용할 수 있을 것으로 기대된다.

프리컷 방식을 적용한 기둥-보 공법의 수평전단내력 (Shear Performance of Post and Beam Construction by Pre-Cut Process)

  • 황권환;박주생;박문재
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권6호
    • /
    • pp.1-12
    • /
    • 2007
  • 한국형 목조건축 실현 및 국내산 조림 낙엽송의 유효 이용을 위해 전통목구조에 있어 널리 사용되는 짜맞춤 공법을 응용한 기계 프리컷 방식으로 드리프트 핀 접합한 낙엽송 집성재 기둥-보 곡법에 대해 수평전단내력성능을 평가하였다. 기계 프리컷 가공된 부재로부터 기둥-보 공법으로 이루어진 골조구조체, 골조와 경골목구조 공법을 혼용한 벽구조체에 대해 현행 KS F 2154 기준에 의거하여 수평전단반복시험을 행하여 얻어진 하중-변위로부터 전단 변형과 전단력의 관계를 산출하였다. 무재하식 수평전단 가력에 의해 최대 전단내력을 골조구조체에서 1.9 kN/m, 벽구조체에서 9.7 kN/m, 전단강성계수는 167 kN/rad, 8198 kN/rad로 각각 나타났다. 골조구조체는 벽구조체에 비해 하중 분담률이 20% 정도, 강성에 있어서는 2% 정도로 나타났으며, 전단내력벽의 최대 전단내력은 골조에 비해 상대적으로 변형성능이 낮게 나타났다. 일본건축학회의 벽배율 산정법에 의한 전단내력벽의 벽배율은 1.5로 산출되었다. 전단내력벽의 전단성능 향상을 위해서는 주각부 및 기둥-보, 못과 면재에 대한 차후 검토와 수평전단 가력법에 대한 검토가 필요한 것으로 판단되었다.

집성재 볼트 결합부의 강도 성능 개선에 관한 연구 (Study on the Improvement of Strength Capacity for Glulam-to-bolt Connection)

  • 김광철
    • Journal of the Korean Wood Science and Technology
    • /
    • 제33권6호통권134호
    • /
    • pp.31-37
    • /
    • 2005
  • 본 연구는 각 결합부 조건에 따른 결합부의 강도적 성능 증가를 살펴보고자 하였다. 주 부재로 집성재를, 측면 부재로 3 mm 두께의 강철판을 사용하여 제작하였으며, 1 mm 두께의 강철판을 개수를 달리하여 집성재에 삽입하여 결합부를 제조하였다. 본 연구를 통해 아주 얇은 두께의 강철판이라도 대단면 부재인 집성재 내부에 삽입하여 결합부를 제조할 경우 강도에 상당한 증가를 보였다. 집성재 결합부는 강철판을 삽입하지 않은 A 그룹, 강철판을 1개 삽입한 B 그룹, 강철판을 2개 삽입한 C 그룹, 그리고 강철판을 3개 삽입한 D 그룹으로 각각 분류하였다. 강철판을 삽입하지 않은 A 그룹에 비해 강철판을 1개 삽입한 B 그룹은 최대값과 항복 하중값을 각각 18%, 13%, 강철판을 2개 삽입한 C 그룹은 27%, 20%, 강철판을 3개 삽입한 경우 33%, 24%의 강도 증가를 보였다. 하지만 집성재 내부에 얇은 두께의 강철판을 삽입하는데 필요한 추가적인 경제적 기술적 어려움으로 인해 강철판 삽입으로서 얻을 수 있는 강도적 성능 증가와 그에 따른 어려움을 충분히 고려해야 할 것이다.