• 제목/요약/키워드: structural wall

검색결과 1,733건 처리시간 0.025초

Study on a seismic slit shear wall with cyclic experiment and macro-model analysis

  • Jiang, Huanjun;Lu, Xilin;Kwan, A.K.H.;Cheung, Y.K.
    • Structural Engineering and Mechanics
    • /
    • 제16권4호
    • /
    • pp.371-390
    • /
    • 2003
  • The concept of the seismic slit shear wall was proposed in the early 1990's. A series of experimental and theoretic studies on the wall with reinforced concrete short connecting beams cast in the slit were carried out. In this paper another type of slit shear wall is studied. It is one with vertical slit purposely cast within the wall, and the rubber belt penetrated by a part of web shear reinforcement as seismic energy-dissipation device is filled in the slit. Firstly, an experiment under cyclic loading was carried out on two shear wall models, one slit and the other solid. The failure mechanism and energy-dissipation capacity are compared between the two different models, which testifies the seismic performance of the slit wall improved significantly. Secondly, for engineering practice purpose, a macroscopic analytical model is developed to predict the nonlinear behavior of the slit shear wall under cyclic loading. The mechanical properties of each constituent elements of this model are based on the actual behavior of the materials. Furthermore, the effects of both the axial force and bending moment on the shear behavior are taken into account with the aid of the modified compression-field theory. The numerical results are verified to be in close agreement with the experimental measurements.

고층 아파트 구조시스템에 따른 내진성능 분석 (Seismic Capacity according to Structural System of High-rise Apartment)

  • 이민희;조소훈;김종호;김형도
    • 한국전산구조공학회논문집
    • /
    • 제32권3호
    • /
    • pp.149-154
    • /
    • 2019
  • 국내 고층 아파트의 구조시스템은 크게 다수의 벽체가 분산적으로 배치되어 있는 내력벽 시스템과 중앙 코어벽 시스템으로 구분할 수 있다. 각각 시스템에 따른 횡방향 거동을 분석하기 위해 본 연구는 국내 고층 아파트 중 대표적인 평면을 갖는 대상 건물을 선정하고, 비선형 정적해석을 수행하여 붕괴메커니즘을 살펴보았다. 비선형 정적해석을 통해 도출된 힘-변위관계로부터 지진응답에 있어서 중요한 요소인 초과강도계수 및 연성도계수를 산정하여 반응수정계수를 평가하였다. 중앙 코어벽 시스템은 연성도는 작지만, 풍하중에 의해 지배되어 초과강도가 크게 산정돼 초과강도계수에 의해 반응수정계수가 산정되었고, 내력벽 시스템은 벽량이 많아 연성도가 크기 때문에 상당힌 큰 반응수정계수가 산정된다.

식생블록옹벽의 구조적 안전성 해석과 보강설계기법 연구 (Development of Strengthening Method and Safety Analysis of Ecological Block and Vegetation Bank Protection)

  • 오병환;조인호;이영생;이근희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.207-215
    • /
    • 2003
  • Developed is a new environment-friendly concrete-block retaining wall system. The conventional analysis methods are not directly applicable because the proposed concrete-block wall system is made of by interlocking the blocks with shear keys. Therefore, the shear analysis as well as stability analysis have been conducted to secure the safety of block-wall system. Overall slope stability analysis was also performed. An appropriate strengthening method was developed to ensure the safety when the block-wall system is relatively high. The method of analysis for strengthening the concrete-block wall system was also proposed. The proposed environment-friendly concrete block retaining wall system shows reasonable safety and can be a good construction method for retaining walls and river bank walls.

Experimental studies into a new type of hybrid outrigger system with metal dampers

  • Wang, A.J.
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.183-194
    • /
    • 2017
  • This paper presents the experimental investigation into a new type of steel-concrete hybrid outrigger system developed for the high-rise building structure. The steel truss is embedded into the reinforced concrete outrigger wall, and both the steel truss and concrete outrigger wall work compositely to enhance the overall structural performance of the tower structures under extreme loads. Meanwhile, metal dampers of low-yield steel material were also adopted as a 'fuse' device between the hybrid outrigger and the column. The damper is engineered to be 'scarified' and yielded first under moderate to severe earthquakes in order to protect the structural integrity of important structural components of the hybrid outrigger system. As such, not brittle failure is likely to happen due to the severe cracking in the concrete outrigger wall. A comprehensive experimental research program was conducted into the structural performance of this new type of hybrid outrigger system. Studies on both the key component and overall system tests were conducted, which reveal the detailed structural response under various levels of applied static and cyclic loads. It was demonstrated that both the steel bracing and concrete outrigger wall are able to work compositely with the low-yield steel damper and exhibits both good load carrying capacities and energy dispersing performance through the test program. It has the potential to be applied and enhance the overall structural performance of the high-rise structures over 300 m under extreme levels of loads.

Wavenumber analyses of panel vibrations induced by transonic wall-bounded jet flow from an upstream high aspect ratio rectangular nozzle

  • Hambric, Stephen A.;Shaw, Matthew D.;Campbell, Robert L.
    • Advances in aircraft and spacecraft science
    • /
    • 제6권6호
    • /
    • pp.515-528
    • /
    • 2019
  • The structural vibrations of a flat plate induced by fluctuating wall pressures within wall-bounded transonic jet flow downstream of a high-aspect ratio rectangular nozzle are simulated. The wall pressures are calculated using Hybrid RANS/LES CFD, where LES models the large-scale turbulence in the shear layers downstream of the nozzle. The structural vibrations are computed using modes from a finite element model and a time-domain forced response calculation methodology. At low flow speeds, the convecting turbulence in the shear layers loads the plate in a manner similar to that of turbulent boundary layer flow. However, at high nozzle pressure ratio discharge conditions the flow over the panel becomes transonic, and the shear layer turbulence scatters from shock cells just downstream of the nozzle, generating backward traveling low frequency surface pressure loads that also drive the plate. The structural mode shapes and subsonic and transonic surface pressure fields are transformed to wavenumber space to better understand the nature of the loading distributions and individual modal responses. Modes with wavenumber distributions which align well with those of the pressure field respond strongly. Negative wavenumber loading components are clearly visible in the transforms of the supersonic flow wall pressures near the nozzle, indicating backward propagating pressure fields. In those cases the modal joint acceptances include significant contributions from negative wavenumber terms.

벽식구조 아파트 리모델링을 위한 전단벽 신설공법의 내진성능 분석 (An Analysis on the seismic Performance of Additional Shear-Wall Construction for the Remodeling of Shear-Wall Type Apartment Buildings)

  • 홍건호;정우경
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.153-162
    • /
    • 2007
  • 1988년 이전에 건설된 벽식 구조 아파트는 내진규정의 적용을 받지 않아 리모델링을 위해서는 현행법규에 적합한 내진보강이 필요하다. 본 연구에서는 벽체 신설 공법에 의한 내진 보강효과를 분석하기 위하여, 개발된 리모델링 건축 평면 내에서 전단벽의 신설이 가능한 위치별 보강 효과와 벽량 및 벽두께의 변화에 따른 내진 보강 효과를 분석하도록 하였다. 내진성능의 평가는 층간 횡 변위를 이용하여 허용 층간변위의 만족여부에 의하여 분석하였으며, 건축물의 구조 모델은 슬래브의 횡 방향 기여도를 고려한 유효보 모델을 사용하였다. 본 연구의 결과에 따르면 리모델링 시 단위 모듈별 내진보강이 가능하며, 전단벽의 신설 위치와 벽량에 따라 건물 건체의 거동에 영향을 받는 것을 확인 할 수 있다.

개구부 설치를 위해 인위적 손상을 가한 전단벽의 구조성능 평가 (Structural Performance of Reinforced Concrete Shear Walls Partially Cutted for Opening)

  • 최윤철;최현기;최창식;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권3호
    • /
    • pp.77-86
    • /
    • 2007
  • 건축물의 증가와 자원의 효율적인 활용의 목적으로 기존 건축물에 대한 리모델링이 주목을 받고 있다. 리모델링 공사로 인해 세대간 병합을 위해 기존 벽에 개구부를 설치하는 경우 개구부의 영향을 파악 하는 것을 목적으로 철근콘크리트 전단벽의 정적가력 실험을 실시했다. 그 결과 개구부 유무에 따른 파괴현상은 벽판에 형성된 압축지주의 단면적이 감소함으로써 다르게 나타났다. 특히 최대 내력은 개구부 설치에 따라 약 35%정도 감소되는 특성을 보였다. 이러한 경향은 강성 및 에너지 소산능력에서도 유사하게 나타났다.

The length of plastic hinge area in the flanged reinforced concrete shear walls subjected to earthquake ground motions

  • Bafti, Farzad Ghaderi;Mortezaei, Alireza;Kheyroddin, Ali
    • Structural Engineering and Mechanics
    • /
    • 제69권6호
    • /
    • pp.651-665
    • /
    • 2019
  • Past earthquakes have shown that appropriately designed and detailed buildings with shear walls have great performance such a way that a considerable portion of inelastic energy dissipation occurs in these structural elements. A plastic hinge is fundamentally an energy diminishing means which decrease seismic input energy through the inelastic deformation. Plastic hinge development in a RC shear wall in the areas which have plastic behavior depends on the ground motions characteristics as well as shear wall details. One of the most generally used forms of structural walls is flanged RC wall. Because of the flanges, these types of shear walls have large in-plane and out-of-plane stiffness and develop high shear stresses. Hence, the purpose of this paper is to evaluate the main characteristics of these structural components and provide a more comprehensive expression of plastic hinge length in the application of performance-based seismic design method and promote the development of seismic design codes for shear walls. In this regard, the effects of axial load level, wall height, wall web and flange length, as well as various features of earthquakes, are examined numerically by finite element methods and the outcomes are compared with consistent experimental data. Based on the results, a new expression is developed which can be utilized to determine the length of plastic hinge area in the flanged RC shear walls.

철근콘크리트 프레임면내 조적벽체의 내진성능 평가 및 개선기술 (Improvement and Evaluation of Seismic Resistant Performance of Reinforced Concrete Infilled Masonry Frame)

  • 신종학;하기주;전하석;이종찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권1호
    • /
    • pp.147-155
    • /
    • 2000
  • Five reinforced concrete rigid frame and masonry infilled wall and cut off type masonry infilled wall were tesed during vertical and cyclic loads simultaneously. Experimental programs were accomplished to improve and evaluate the structural performance of test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Test variables are hoop reinforcement ratio, with or without masonry infilled wall, and masonry method. All the specimens were constructed in one-third scale size. Based on the test results, the following conclusions can be made. For masonry infilled wall(IFB-1), maximum horizontal capacity was increased by 1.45 time in comparision with that of rigid frame(FB-0). For cut off masonry infilled wall (IFBC-1~3), maximum horizontal capacity was increased by 1.73~1.98 time in comparision with that of rigid frame(FB-0). For cut off masonry infilled wall(IFBG-1~3), ductility was increased by 1.48~2.08 time in comparision with that of masonry infilled wall (IFB-1).

  • PDF

Behavior, Design, and Modeling of Structural Walls and Coupling Beams - Lessons from Recent Laboratory Tests and Earthquakes

  • Wallace, John W.
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권1호
    • /
    • pp.3-18
    • /
    • 2012
  • Observed wall damage in recent earthquakes in Chile and New Zealand, where modern building codes exist, exceeded expectations. In these earthquakes, structural wall damage included boundary crushing, reinforcement fracture, and global wall buckling. Recent laboratory tests also have demonstrated inadequate performance in some cases, indicating a need to review code provisions, identify shortcomings and make necessary revisions. Current modeling approaches used for slender structural walls adequately capture nonlinear flexural behavior; however, strength loss due to buckling of reinforcement and nonlinear and shear-flexure interaction are not adequately captured. Additional research is needed to address these issues. Recent tests of reinforced concrete coupling beams indicate that diagonally-reinforced beams detailed according to ACI 318-$11^1$ can sustain plastic rotations of about 6% prior to significant strength loss and that relatively simple modeling approaches in commercially available computer programs are capable of capturing the observed responses. Tests of conventionally-reinforced beams indicate less energy dissipation capacity and strength loss at approximately 4% rotation.