• Title/Summary/Keyword: structural performance test

Search Result 2,163, Processing Time 0.029 seconds

Flexural Capacity of Concrete Beam Strengthened with Near-Surface Mounted Carbon Fiber Reinforced Polymer (탄소섬유 보강재로 표면매립에 의해 보강된 철근 콘크리트 보의 휨 보강성능)

  • Oh, Hong Seob;Sim, Jong Sung;Ju, Min Kwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.84-92
    • /
    • 2008
  • This study is to investigate the flexural performance of Near Surface Mounted (NSM) strengthening method using Fiber reinforced Polymer (FRP) materials to concrete structures. For this study, the inverse-shaped trapezoid CFRP composite material which has been registered as New Excellent Technology (NET) 351 was adopted to the concrete structure. In this study, two types of the CFRP types were considered; Type A ($15{\times}13{\times}6mm$) and Type B ($4{\times}3{\times}10mm$) with different strengthening ratio. In the result of the test, it was proved that NSM strengthened specimens had more flexural performance of 20-100% than that of the unstrengthened specimen. With this test result, the structural efficiency was investigated based on the coefficient of ductility and coefficient of crack resistance.

A Study of Weldability and Welded Joint Performance on the Gas Shield Arc Welding (FCAW) of SM490TMC Steel Plate (120mm) (SM490TMC 극후판(120mm) 강재의 가스실드아크용접(FCAW)을 이용한 용접성 및 이음성능에 관한 연구)

  • Kim, Sung Bae;Hong, Hyung Ju;Choi, Young Han;Kim, Sang Seup
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.455-465
    • /
    • 2017
  • To figure out the weldability and welded joint performance on the FCAW of SM490TMC 120mm, several specimens were manufactured and 10 kinds of experiments were implemented. The result of the weld zone chemical composition test, weld metal tensile test, weld zone tensile test, and weld zone impact test has satisfied the KS. Especially, the weld zone tensile test result shows the base metal fracture, which means the weld zone performs enough required performance. In addition, the results of the weld zone bending test, hardness test, macroscopic test, microscopic test, and the maximum hardness in HAZ were showing that the FCAW weld zone has fine quality.

Structural Relationship between Salesperson's Perceived Evaluation Fairness and Job Performance in the Financial Market (금융시장에서 영업사원의 지각된 평가 공정성과 직무성과 간의 구조적 관계)

  • Lee, Jun-Seop;Kim, Ji-Young;Lee, Han-Geun
    • Journal of Distribution Science
    • /
    • v.14 no.12
    • /
    • pp.141-151
    • /
    • 2016
  • Purpose - Salesperson perceptions of the fairness and accuracy of a performance evaluation system were examined by managerial and professional employees of large organization. The performance evaluation process is central to many personal decisions such as attitude for job and sales performance. This study investigates the relationship between perceived evaluation fairness, job satisfaction, organizational commitment, and sales performance. The main purpose of this study is to develop and empirically test a comprehensive model of salespersons' perceived evaluation fairness on sales performance. For this purpose, we identified the structural relationship between perceived evaluation fairness, job satisfaction, organizational commitment, and sales performance. Also we investigate the mediating effects on job satisfaction and organizational commitment between perceived evaluation fairness and sales performance. Research design, data, and methodology - To empirically test these relationships, data were collected by in-depth interviews from sales managers and questionnaire surveys from 300 salespersons who work for sales area (credit card company, insurance company). Demographically, the overall sample was 91.6% female, 77.9% 30s and 40s, and 34% college educated, with an average tenure with their present organizations of 4 years. The questionnaire was composed of total 20 items dealing with frequency, quality, and consequences of perceived evaluation fairness, job satisfaction, organizational commitment, and sales performance. To test the research hypotheses, collected data analyzed by confirmatory factor analysis (CFA) and structure equation model (SEM). Results - Through extensive and rigorous literature review process of related literature(Perceived evaluation fairness, Job satisfaction, Organizational commitment, Sales performance), research model and research hypothesis was set up. This study obtains the following research results. First, perceived evaluation fairness has a positive effect on job satisfaction, whereas the effects of perceived evaluation fairness on organizational commitment and sales performance did not show statistically significant result. Second, job satisfaction and organizational commitment have complete mediating roles to the relationship between perceived evaluation fairness and organizational commitment, and relationship between perceived evaluation fairness and sales performance. Conclusions - Based on the results, salespersons' perceived evaluation fairness is one of the key independent variable for making high job satisfaction, organizational commitment, and sales performance. Finally the theoretical, managerial implication and research limitations are mentioned in the discussion.

Seismic Test of the Control Rod Drive Mechanism for JRTR (JRTR 제어봉구동장치의 내진시험)

  • Choi, Myoung-Hwan;Kim, Gyeong-Ho;Sun, Jong-Oh;Cho, Yeong-Garp
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.552-558
    • /
    • 2016
  • A control rod drive mechanism(CRDM) is a reactor regulating system, which inserts, withdraws or maintains a control rod within a reactor core to control the reactivity of the core. The CRDM for Jordan Research and Training Reactor with 5MW power has been designed and fabricated based on the HANARO’s experience through KAERI and DAEWOO consortium. This paper describes the seismic test results to demonstrate the operability, the drop performance and the structural integrity of CRDM during or after seismic excitations. The seismic tests are carried out under 5 OBE and 1 SSE loads at three Test Rigs simulating the reactor structure and the pool top. From the tests, the CRDM is smoothly driven without a malfunction of stepping motor under OBE load. The pure drop time under OBE and SSE loads is measured as 1.169s and 1.855s to meet the design requirement. Also, it is found that the CRDM maintains the structural integrity without a change of the function and natural frequency before and after seismic loads.

The Leakage Reduction of Natural Inorganic Powder Compound Applying Subsurface Structural Weak Part (지하구조물 취약부에 적용한 천연 무기질계 분말형 혼화제의 누수저감효과)

  • Yoon, Sung-Hwan;Seo, Hyun-Jae;Lee, Hye-Ryung;Park, Jin-Sang;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.19-22
    • /
    • 2011
  • For underground structures that are exposed to environmental conditions, the declination of the durability of concrete occurs easily because of leakages from high hydraulic pressure and the frequent contact of water due to environmental factors. Therefore this study is to confirm that the leakage reduction of natural inorgnic powder compound applying subsurface structural weak part and make the performance improvement of concrete as an objective. The test was done by making the rebar, flat tie, nail and film infiltration and each of its water tank and cylindrical test body then after pouring water to each of the test body, the test observe the change of the water tank surface absorbed condition and leakage of each specimen with respect to time. As a conclusion, the test was observed that this water proofing admixture has better watertightness from the beginning of the setting time(when it hardens), the ettringite and the thaumasite generates a large quantity of hydration products that controls the formation in a large opening and the CSH produced by pozzolan reaction makes a dent at this opening.

  • PDF

Structural modal identification and MCMC-based model updating by a Bayesian approach

  • Zhang, F.L.;Yang, Y.P.;Ye, X.W.;Yang, J.H.;Han, B.K.
    • Smart Structures and Systems
    • /
    • v.24 no.5
    • /
    • pp.631-639
    • /
    • 2019
  • Finite element analysis is one of the important methods to study the structural performance. Due to the simplification, discretization and error of structural parameters, numerical model errors always exist. Besides, structural characteristics may also change because of material aging, structural damage, etc., making the initial finite element model cannot simulate the operational response of the structure accurately. Based on Bayesian methods, the initial model can be updated to obtain a more accurate numerical model. This paper presents the work on the field test, modal identification and model updating of a Chinese reinforced concrete pagoda. Based on the ambient vibration test, the acceleration response of the structure under operational environment was collected. The first six translational modes of the structure were identified by the enhanced frequency domain decomposition method. The initial finite element model of the pagoda was established, and the elastic modulus of columns, beams and slabs were selected as model parameters to be updated. Assuming the error between the measured mode and the calculated one follows a Gaussian distribution, the posterior probability density function (PDF) of the parameter to be updated is obtained and the uncertainty is quantitatively evaluated based on the Bayesian statistical theory and the Metropolis-Hastings algorithm, and then the optimal values of model parameters can be obtained. The results show that the difference between the calculated frequency of the finite element model and the measured one is reduced, and the modal correlation of the mode shape is improved. The updated numerical model can be used to evaluate the safety of the structure as a benchmark model for structural health monitoring (SHM).

Development of the Passive Outside Insulation Composite Panel for Energy Self-Sufficiency of Building in the Region (지역 건축물의 에너지 자립을 위한 패시브 외단열 복합패널 개발 연구)

  • Moon, Sun-Wook
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2018
  • The study aims to address the energy crisis and realize self-sufficiency of building as part of local energy independence, breaking away from a single concentrated energy supply system. It is intended to develop modules of the outside insulation composite panels that conform to passive certification criteria and for site-assembly systematization. The method of study first identifies trends and passive house in literature and advanced research. Second, the target performance for development is set, and the structural material is selected and designed to simulate performance. Third, a test specimen of the passive outside insulation curtain wall module designed is manufactured and constructed to test its heat transmission coefficient, condensation performance and airtightness. Finally, analyze performance test results, and explore and propose ways to improve the estimation and improvement of incomplete causes to achieve the goal. The final test results achieved the target performance of condensation and airtightness, and the heat transmission coefficient was $0.16W/(m^2{\cdot}K)$, which is $0.01W/(m^2{\cdot})K$ below the performance target. As for the lack of performance, we saw a need for a complementary design to account for simulation errors. It also provided an opportunity to recognize that insulated walls with performance can impact performance at small break. Thus, to be commercialized into a product with the need for improvement in the design of the joint parts, a management system is needed to increase the precision in the fabrication process.

High-Temperature Structural Analysis Model of the Process Heat Exchanger for Helium Gas Loop (II) (헬륨가스루프 시험용 공정열교환기에 대한 고온구조해석 모델링(II))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Chan-Soo;Hong, Seong-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1455-1462
    • /
    • 2010
  • PHE (Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute established the helium gas loop for the performance test of components, which are used in the VHTR, and they manufactured a PHE prototype to be tested in the loop. In this study, as part of the hightemperature structural-integrity evaluation of the PHE prototype, which is scheduled to be tested in the helium gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal expansion analysis of the PHE prototype. The results obtained in this study will be used to design the performance test setup for the PHE prototype.

Structural efficiency of various strengthening schemes for cold-formed steel beams: Effect of global imperfections

  • Dar, M. Adil;Subramanian, N.;Dar, A.R.;Majid, Muheeb;Haseeb, Mohd;Tahoor, Mugees
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.393-403
    • /
    • 2019
  • Cold-formed steel (CFS) has a great potential to meet the global challenge of fast-track and durable construction. CFS members undergo large buckling instabilities due to their small wall thickness. CFS beams with corrugated webs have shown great resistance towards web buckling under flexure, when compared to the conventional I-sections. However, the magnitude of global imperfections significantly affects the performance of CFS members. This paper presents the first attempt made to experimentally study the effect of global imperfections on the structural efficiency of various strengthening schemes implemented in CFS beams with corrugated webs. Different strengthening schemes were adopted for two types of beams, one with large global imperfections and the other with small imperfections. Strength and stiffness characteristics of the beams were used to evaluate the structural efficiency of the various strengthening schemes adopted. Six tests were performed with simply supported end conditions, under four-point loading conditions. The load vs. mid-span displacement response, failure loads and modes of failure of the test specimens were investigated. The test results would compensate the lack of experimental data in this area of research and would help in developing numerical models for extensive studies for the development of necessary guidelines on the same. Strengthening schemes assisted in enhancing the member performance significantly, both in terms of strength and stiffness. Hence, providing an economic and time saving solution to such practical structural engineering problems.