• 제목/요약/키워드: structural performance test

검색결과 2,163건 처리시간 0.034초

옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구 (A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs)

  • 오상근;곽규성;선윤숙;권시원
    • 한국건축시공학회지
    • /
    • 제7권1호
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

철근콘크리트 골조의 내진보강을 위한 신기술 개발 (Development of Now Technique for Earthquake-Resistant Retrofit in Reinforced Concrete Frame)

  • 하기주;신종학;최민권;조용태;조용태;이상목;이영범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.69-74
    • /
    • 2000
  • In this dissertation, experimental research was carried out to study the hysteretic behavior of reinforced concrete frame designed by high performance techniques, using carbon fiber plate, diagonal bracing system with or without steel frame. Experimental programs were carried to evaluate the structural performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Specimens(RFCP, RFXB, RFXB-F), designed by the improvement of earthquake-resistant performance, were attained more load-carrying load-carrying capacity stable hysteretic behavior.

  • PDF

Structural Performance of Reinforced Concrete Flat Plate Buildings Subjected to Fire

  • George, Sara J.;Tian, Ying
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권2호
    • /
    • pp.111-121
    • /
    • 2012
  • The research presented in this paper analytically examines the fire performance of flat plate buildings. The modeling parameters for the mechanical and thermal properties of materials are calibrated from relevant test data to minimize the uncertainties involved in analysis. The calibrated models are then adopted to perform a nonlinear finite element simulation on a flat plate building subjected to fire. The analysis examines the characteristics of slab deflection, in-plane deformation, membrane force, bending moment redistribution, and slab rotational deformation near the supporting columns. The numerical simulation enables the understanding of structural performance of flat plate under elevated temperature and, more importantly, identifies the high risk of punching failure at slab-column connections that may trigger large-scale failure in flat plate structures.

슬림 AU 합성보의 내화해석 (Fire Performance Analysis of SLIM AU Composite Beam)

  • 김명한;오명호;민정기
    • 한국공간구조학회논문집
    • /
    • 제16권4호
    • /
    • pp.133-140
    • /
    • 2016
  • SLIM AU(A plus U-shaped) composite beam had been developed for not only reducing the story height in residential and commercial building, but also saving the cost of floor construction. The structural performance and economic feasibility was sufficiently approved by means of structural experiments and analytical studies. Even though fire resistance of the SLIM AU composite beam was evaluated throughout furnace fire test, the fire performance of the composite beam using finite element analysis is not analysed yet. Therefore the predictions of fire resistance simulations with loading as well as temperature distribution of the composite beam are summarized in this paper.

반복 횡하중을 받는 프리캐스트 대형 판구조의 내진성능에 관한 연구 (Seismic Performance of Precast Concrete Large Panel Structures Subjected to Horizontal Cyclic Loading)

  • 서수연;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.261-268
    • /
    • 1999
  • The seismic performance of precast concrete panel structures tested previously has been evaluated in this paper. Hysteretic curves of test specimens are idealized to elasto-plastic curves to get reliable yielding and ultimate displacements. For the idealized curves, ductility and energy dissipation capacity of specimens have been evaluated using a few guide lines. In addition, the strength capacity of specimens is checked for the strength demand caused by the design earthquake load including overturning moment effects. The result shows while the strength of specimen with joint box for vertical continuity is little bit lower than that of specimen connected by welding, the ductility of the former is higher than that of the latter. The energy dissipation ratios of PC specimens are ranged from 83% to 96% of that of Re specimen and the average of those are shown 90%.

  • PDF

버팀보 해체시 안전성 확보를 위한 응력 해제용 굴절지지대 개발 및 성능 평가 (Development and Performance Evaluation of Rotational Strut Segment for Releasing Stress when uninstalled)

  • 박철용;구일근;김현숙;양지연;김형오
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2018
  • Preloading Strut applied during installation of the wall jack, but additionally serves to minimize the displacement of soil pressure acting upon dissolution due to the difficulty. In this study, we developed an index of support for the release of stress to facilitate the dismantling of the strut uninstall. The refractive support the axial force acting on the strut are supportable, is refracted at minimum load, disassembly should be easy. In order to find the optimal shape and structural stability of the refractive support We have performed the numerical analysis and performance test to determine the final model. We carried out model tests and UTM test in order to understand the refractive performance and durability of the refractive support for optimal model. Results of the test UTM is refracted all shot 5 times within a target hit number, it was found that there is no problem of the refractive performance. Further, the results of model experiments, it was found that to ensure sufficient durability more than the performance target value of the pin joint support structure.

  • PDF

경수로용 고유 지지격자의 성능시험 (Performance Test on the KAERI Designed Spacer Grids for the Advanced PWR)

  • 송기남;윤경호;강흥석;김형규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.431-437
    • /
    • 2003
  • KAERI has contrived 14 kinds of spacer grid shapes of its own since 1997 and applied for Korean and US patents. To date. KAERI has obtained US and Korean patents for 6 kinds of spacer grid shapes among them. Tn this study. performance test on two spacer grid shapes that are assumed to be the most effective candidates for the spacer grid of the next generation nuclear fuel in Korea was carried Qui through the mechanical/structural test and analysis. The test result has shown thai the performances of the candidates are better or not worse than that of the current spacer grid.

  • PDF

콘크리트포장의 박층 콘크리트 덧씌우기공법 (Thin Bonded Concrete Overlay for Concrete Pavement Rehabilitation)

  • 윤경구;이형준;엄주용;서영찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.635-642
    • /
    • 1997
  • This research focused on the development of concrete overlay and test, which was conducted at 88 Highway 105k, 2 lanes of 290 m. The field application test consists of 6 cm and 10 cm bonded concrete overlay and 25 cm unbonded concrete overlay, using the slag cement for opening lanes for traffic early. The overlay were placed in a day. The whole period of traffic closing wes 8 day and it was reopened to traffic after concrete overlay has cured for 3 day. 5 cracks were founded when the field test section was investigated after 1 month, but all these may not make significant problems to overlay because these initiated and growed at the same line of repair section. The rideability and skid resistance become much better like in the new pavement after overlay. The structural capacity against deflection was much. which were verified by FWD(Falling Weight Deflectometer). The field test section is being used in a good condition and the results of field application and pavement performance analysis are encouraging. This rehabilitation methods may be adopted in Korea after a more field performance verifications.

  • PDF

통신 항법용 다중대역 안테나 내장 스킨구조의 지상시험평가 (Ground Test & Evaluation of Conformal Load-bearing Antenna Structure for Communication and Navigation)

  • 김민성;박찬익;조창민;전승문
    • 한국항공우주학회지
    • /
    • 제41권11호
    • /
    • pp.891-899
    • /
    • 2013
  • 본 논문에서는 전투기 주구조물에 적용할 수 있는 안테나 내장 스킨구조(CLAS)의 새로운 시험평가 절차를 제시하였다. 대수 주기 패치형 안테나를 통신항법용 다중대역 안테나로 설계하였다. 탄소/유리 섬유 강화 적층 복합재(CFRP/GFRP)를 공력하중을 지지하기 위한 구조로 사용하고 안테나 성능 향상을 위해 하니컴 층을 적층하였다. 여러 재질로 구성된 다층구조의 안테나 내장 스킨구조를 고온의 오븐에서 경화하였다. 내장된 안테나의 이득, 전압 정재파비, 방사패턴을 0.15GHz~2GHz 주파수 범위에서 무반향 챔버시설을 이용하여 측정하였다. 안테나 내장 스킨구조의 구조강도를 평가하기 위하여 인장, 전단, 피로, 충격 하중을 부가하는 구조시험을 수행하였다. 각각의 구조시험 후에 안테나 성능시험을 수행하여 초기 값과 비교하므로써 구조시험이 안테나에 미치는 영향을 확인하였다. 새로 개발한 안테나 내장 스킨구조 시험평가 절차를 통신항법용 CLAS에 적용하여 설계개선이 필요한 점을 발견하였다.

미끄럼방지포장 유지관리를 위한 미끄럼저항 성능평가방법 비교 연구 (A Comparative Study on Skid Resistance Performance Evaluation Methods for Maintenance of Skid Resistance Pavement)

  • 조현우;노상균;이봉춘;정윤석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.79-85
    • /
    • 2023
  • 미끄럼방지포장은 도로의 부속물로서 도로 및 교통 특성으로 인해 미끄럼저항을 충분히 확보하지 못한 곳이나 도로선형의 변화가 심한 구간에서 포장의 미끄럼저항을 높여 자동차의 안전한 주행을 도모하기 위한 시설이라고 명시하고 있다. 특히, 눈, 비, 블랙아이스와 같은 기상 악천후 상황에서 미끄럼방지포장의 미끄럼저항성능은 도로교통 및 운전자의 안전에 큰 영향을 미친다. 하지만 현재 미끄럼저항성능을 측정하는 데 주로 사용되는 BPN은 시험 면적이 0.009 m2에 불과하여 전체 포장면에 대한 대표성을 나타내기 어렵기 때문에 미끄럼방지포장 유지관리를 위한 신뢰성 있는 미끄럼저항성능 평가방법이 필요한 실정이다. 본 연구에서는 지침 및 표준 조사를 통하여 BPN, SN, GN 시험의 미끄럼저항 성능평가 방법을 비교하고 현장 미끄럼저항 성능평가에 적용하고자 하였다. 또한, 미끄럼방지포장의 체계적인 유지관리를 위하여 미끄럼방지포장재 미끄럼저항 성능평가 Test-bed 및 실도로 실증 현장에 미끄럼저항성능이 다른 미끄럼방지포장을 설치하여 성능평가방법(BPN, SN, GN)별 미끄럼저항성능을 비교하였다. 실험결과, SN과 GN은 미끄럼저항성능이 비슷한 경향으로 나타났으며, GN은 BPN × 0.01 과 유사하게 도출되었다.