1 |
Lim, L., Buchanan, A., Moss, P., & Franssen, J. (2004). Numerical modelling of two-way reinforced concrete slabs in fire. Engineering Structures, 26(8), 1081-1091.
DOI
ScienceOn
|
2 |
Lim, L., & Wade, C. (2002). Experimental fire tests of two-way concrete slabs. Fire Engineering Research Report 02/12. Christchurch (New Zealand): University of Canterbury.
|
3 |
Lubliner, J., Oliver, J., Oller, S., & On˜ ate, E. (1989). A plasticdamage model for concrete. International Journal of Solids and Structures, 25 299-329.
|
4 |
Moss, P. J., Dhakal, R. P., Wang, G., & Buchanan, A. H. (2008). The fire behaviour of multi-bay, two-way reinforced concrete slabs. Engineering Structures, 30(12), 3566-3573.
DOI
ScienceOn
|
5 |
Muttoni, A. (2008). Punching shear strength of reinforced concrete slabs without transverse reinforcement. ACI Structural Journal, 105(4), 440-450.
|
6 |
Ruiz, M. F., Muttoni, A., & Kunz, J. (2010). Strengthening of flat slabs against punching shear using post-installed shear reinforcement. ACI Structural Journal, 107(4), 434-442.
|
7 |
Tian,Y., Jirsa, J. O., Bayrak, O.,Widianto,&Argudo, J. F. (2008). Behavior of slab-column connections of existing flat-plate structures. ACI Structural Journal, 105(5), 561-569.
|
8 |
Vermeer, P. A., & De Borst, R. (1984). Non-associated plasticity for soils, concrete, and rock. HERON, 29(3), 1-62.
|
9 |
Wang, G. (2004). Performance of reinforced concrete flat slabs exposed to fire. Fire Engineering Research report number 06/2. Christchurch (New Zealand): University of Canterbury
|
10 |
ACI Committee 318. ( 2011). Building code requirements for structural concrete (ACI 318-11) and commentary. Farmington Hills, MI: American Concrete Institute.
|
11 |
ASCE. (1992). Structural fire protection. Manual No. 78. New York: ASCE Committee on Fire Protection, Structural Division, American Society of Civil Engineers.
|
12 |
ASCE 7-10. (2010). Minimum design loads for buildings and other structures. Reston, VA: American Society of Civil Engineers.
|
13 |
Dassault Systemes Simulia Corporation. (2009). Abaqus 6.9 documentation.
|
14 |
Elstner, R. C., & Hognestad, E. (1956). Shearing strength of reinforced concrete slabs.ACI Journal Proceedings, 53(1), 29-58.
|
15 |
Eurocode 2. (1995). Design of concrete structures. Part 1-2: General rules-structural fire design (ENV1992). Brussels: European Committee for Standardization.
|
16 |
Eurocode 3. (1995). Design of steel structures. Part 1-2: General rules-structural fire design (ENV 1993). Brussels: European Committee for Standardization.
|
17 |
Ghaffar, A., Chaudhry, M. A., & Ali, M. K. (2005). A new approach for measurement of tensile strength of concrete. Journal of Research (Science), 16(1), 1-9.
|
18 |
Guandalini, S., Burdet, O. L., & Muttoni, A. (2009). Punching tests of slabs with low reinforcement ratios. ACI Structural Journal, 106(1), 87-95.
|
19 |
Harmathy, T. Z. (1993) Fire safety design and concrete. Harlow: Longman Scientific & Technical.
|
20 |
Huang, Z., Burgess, I. W., & Plank, R. J. (1999). Nonlinear analysis of reinforced concrete slabs subjected to fire. ACI Structural Journal, 96(1), 127-135.
|
21 |
Joint ACI/TMS Committee 216. (2007). Code requirements for determining fire resistance of concrete and masonry construction assemblies. Farmington Hills, MI: American Concrete Institute.
|
22 |
Lee, J., & Fenves G. L. (1998). Plastic-damage model for cyclic loading of concrete structures. Journal of Engineering Mechanics, 124(8), 892-900.
DOI
ScienceOn
|