• 제목/요약/키워드: structural performance test

검색결과 2,146건 처리시간 0.029초

Structural performance of cold-formed steel column bases with bolted moment connections

  • Chung, K.F.;Yu, W.K.;Wang, A.J.
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2005
  • This paper presents a thorough investigation into the structural performance of cold-formed steel column bases using double lipped C sections with bolted moment connections. A total of four column base tests with different connection configurations were carried out, and it was found that section failure under combined bending and shear was always critical. Moreover, the proposed column bases were demonstrated to be structurally efficient attaining moment resistances close to those of the connected sections. In order to examine the structural behaviour of the column base connections, a finite element model was established using shell and spring elements to model the sections and the bolted fastenings respectively. Both material and geometrical non-linearities were incorporated, and comparison between the test and the numerical results was presented in details. The design rules originally developed for bolted moment connections between lapped Z sections were adopted and re-formulated for the design of column base connections after careful calibration against the test data. Comparison on co-existing moments and shear forces at the critical cross-sections of the column bases was fully presented. It was shown that the proposed design and analysis method was structurally adequate to predict the failure loads under combined bending and shear for column bases with similar connection configurations.

Comparative assessment of seismic rehabilitation techniques on a full scale 3-story RC moment frame structure

  • Di Ludovico, M.;Balsamo, A.;Prota, A.;Manfredi, G.
    • Structural Engineering and Mechanics
    • /
    • 제28권6호
    • /
    • pp.727-747
    • /
    • 2008
  • In the framework of the SPEAR (Seismic PErformance Assessment and Rehabilitation) research Project, an under-designed three storey RC frame structure, designed to sustain only gravity loads, was subjected, in three different configurations 'as-built', Fiber Reinforced Polymer (FRP) retrofitted and rehabilitated by reinforced concrete (RC) jacketing, to a series of bi-directional pseudodynamic (PsD) tests under different values of peak ground acceleration (PGA) (from a minimum of 0.20g to a maximum of 0.30g). The seismic deficiencies exhibited by the 'as-built' structure after the test at PGA level of 0.20g were confirmed by a post - test assessment of the structural seismic capacity performed by a nonlinear static pushover analysis implemented on the structure lumped plasticity model. To improve the seismic performance of the 'as-built' structure', two rehabilitation interventions by using either FRP laminates or RC jacketing were designed. Assumptions for the analytical modeling, design criteria and calculation procedures along with local and global intervention measures and their installation details are herein presented and discussed. Nonlinear static pushover analyses for the assessment of the theoretical seismic capacity of the structure in each retrofitted configuration were performed and compared with the experimental outcomes.

대구경 기계적 철근 이음장치의 구조성능에 관한 실험적 평가 (Experimental Evaluation on Structural Performance of Large Diameter Reinforcing Steel Bars with Spliced Sleeves)

  • 권기주;박동수;정원섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.180-188
    • /
    • 2011
  • 최근 대구경철근에 적용할 수 있는 기계적 철근이음장치에 대한 연구가 진행되고 있다. 본 논문에서는 대구경 기계적 철근이음재에 대한 구조적 성능평가에 대하여 연구가 수행되었다. 원자력발전소에 대구경의 기계적 철근이음장치를 적용하기 위해서 2가지 형태의 철근이음장치에 대한 실험이 수행되었으며, 원자력발전소에 적용되는 11번과 14번 및 18번에 대한 대구경 철근 이음 장치가 조립되어 정적 및 동적실험이 수행되었다. 실험은 ASME SEC III DIV.2 CC-4330에 따라 이루어졌다.

변형에폭시계 재료를 사용한 하부증대 보의 구조적 성능 (Structural Performance of Flexural Members Enlarged with Epoxy Mortar System at Soffit)

  • 홍건호;조하나;신영수;정혜교
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.833-838
    • /
    • 1998
  • This paper is aimed to investigate structural performance of flexural members enlarged with epoxy mortar at soffit. Main test variables are steel ratio and interface treatment method and six test beams are tested to investigate the effect of each test variables on maximum load capacity, load-deflection and moment-curvature relationship, interface behavior and failure mode. Test results show that section enlarged beams can carry almost same load of the monolithic beams with same size and the flexural stiffness and cracking moments are increased about 2.5 times and 50 to 70%of failure moment in comparison with same sized control beam, respectively. However, deflections and curvatures are decreased at the same load and interface fractures are not discovered at the ultimate load.

  • PDF

강재 슬릿과 회전 마찰형 감쇠 장치를 결합한 복합 감쇠 장치의 실험적 구조 성능 평가 (Experimental Evaluation for Structural Performance of Hybrid Damper Combining Steel Slit and Rotational Friction Damper)

  • 김유성;강주원;박병태;이준호
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.101-109
    • /
    • 2019
  • In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.

온도해석과 재하가열시험에 의한 콘크리트 충전 보부재의 내화성능평가에 관한 연구 (Study on Fire Resistance of Beams filled with Concrete at Web Through Temperature Analysis and Load-bearing Fire Tests)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.82-88
    • /
    • 2010
  • 건축 구조물의 주요 구조부는 중력하중의 전달과 수평하중을 견디도록 설계, 시공되어야 함을 물론이고, 화재의 고열환경에서 부수적으로 발생되는 온도에 의한 추가하중을 지지하도록 설계되어야 한다. 강구조 건축물에서의 보부재는 중력 및 횡력 방향의 하중에 더 강한 지지력을 확보하기 위하여 H형강 웨브부분에 콘크리트를 충전하는 타입의 개발 및 적용이 이루어져 왔으나, 내화성능의 평가는 거의 이루어지지 않은 상태이다. 따라서 본 논문에서는 H형강 보부재의 웨브에 일반강도의 콘크리트로 충전된 시험체를 대상으로 열전도 해석에 의한 내화성능과 재하가열시험을 통한 내화성능을 각각 제시하고 상관성을 비교분석하였다.

트러스 철근을 갖는 하프 프리캐스트 슬래브의 휨 내력에 관한 실험적 연구 (An Experimental Study on Bending Performance of Half Precast Concrete Slab with Truss-Reinforcement)

  • 서태석;최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.71-80
    • /
    • 2008
  • 본 연구에서 검토된 슬래브는 트러스 철근이 설치된 하프 프리캐스트 콘크리트(PC) 슬래브로서, 이러한 슬래브의 내력평가에 대한 몇몇 연구결과가 소개되었다. 하지만 합성슬래브의 내력평가에 대한 연구가 대부분이고 하프PC슬래브의 내력평가에 대한 연구는 적으며 특히, 트러스 높이에 따른 슬래브의 구조성능에 관한 연구는 매우 부족한 실정이다. 따라서 본 연구에서는, 트러스 철근이 설치된 하프PC슬래브의 구조성능을 검토하기 위하여 트러스 철근의 높이가 다른 세 종류의 슬래브를 제작하여 휨 실험을 실시하였다.

강섬유보강 철근콘크리트 보의 휨성능 평가 (Evaluation of Flexural Performance of Steel Fiber Reinforced Concrete Beams)

  • 하기주;신종학;주정준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권1호
    • /
    • pp.139-145
    • /
    • 2000
  • In this experimental program specimens. designed by the test variables, such as percentage of steel fiber incorporated, were constructed and tested to evaluate the flexural performance of reinforced steel fiber concrete beams. Based on the test results reported in this study, the following conclusions are made. Comparing with the load-displacement relationship of standard specimen, specimen over 0.5% of steel fiber incorporated, could be improved significantly flexural performance, such as capacity, ductility, and crack pattern. As increasing in quantity of steel fiber incorporated(0.5%~2.0%), the flexural strength of each specimen was shown the enhancement of 13%~40% in comparision with the standard specimen BSS.

  • PDF

지진피해가 심한 벽체의 보수 후 구조성능 평가 (Structural Performance Evaluation of Severely Damaged Walls After Repaired)

  • 오창화;유승욱;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.513-516
    • /
    • 1999
  • The objective of this study is to evaluate the performance of the repaired structural walls which were severly damaged. After damaging the wall specimens by experimental test, the walls were repaired and retested to destruction. For the repairing the severly damaged walls, new concrete and new reinforcing bar are replaced with cracked concrete and the buckled reinforcing bar, respectively. The performance of repaired wall specimens are compared with that of undamaged walls.

  • PDF

PP섬유 혼입 고강도 경량골재콘크리트의 내화특성 (Fire Performance of Structural Lightweight Aggregate Concrete using PP fiber)

  • 송훈;추용식;이종규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.797-800
    • /
    • 2006
  • Normally, Structural light-weight aggregate concrete(LWC) has been main used in high rise building with the object of wight loss. In spite of LWC have the advantage of light-weight, limit the use of strength restrictions by reason that explosive spalling in fire. Especially, LWC is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with fire performance of LWC for the purpose of using PP fibers prevent to explosive spalling. From the experimental test result, LWC is happened explosive spalling.

  • PDF