• 제목/요약/키워드: structural performance of fire resistance

검색결과 139건 처리시간 0.02초

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • 국제초고층학회논문집
    • /
    • 제12권3호
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Enhancing the Fire Performance of Concrete-Filled Steel Columns through System-Level Analysis

  • Fike, R.S.;Kodur, V.K.R.
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.11-21
    • /
    • 2013
  • The use of concrete filling offers a practical alternative for achieving the required stability of steel Hollow Structural Section (HSS) columns under fire conditions. However, current methods for evaluating fire resistance of Concrete Filled Hollow Structural Steel (CFHSS) columns are highly conservative as they are based on an elemental approach without due consideration to structural interactions that occur in framed structural systems. To overcome this limitation, a system level fire resistance analysis was carried out by treating CFHSS columns as part of an overall structural frame. In this analysis, an eight story steel-framed building was modeled under a range of standard and performance-based fire scenarios (including multi-story progressive burn-out fires) to evaluate the contribution of various structural members/assemblies to overall fire resistance. One of the primary factors considered was the use of concrete filling in HSS columns as an alternative to standard W-shape columns. Results from the analysis indicate that the use of CFHSS columns, in place of W-shape columns, in a performance-based environment can fully eliminate the need for applied fire protection to columns, while providing the required level of structural fire resistance.

경계조건에 따른 고강도 H형강 부정정 보부재의 해석적 내화성능 연구 (Study on Fire Resistance Performance According to Boundary Conditions for Beams Made of High-Strength Structural Steels Using Analytical Methods)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.23-28
    • /
    • 2015
  • 건축물의 공간 효율성 증대를 주 목적으로 고강재 강재(SM 520)의 사용이 활성화되고 있으나, 화재와 같은 고온조건에서의 보부재에 대한 내화성능은 검증되지 못하고 있는 실정이다. 따라서 본 연구에서는 SM 520강재가 적용된 양단 고정단 경계조건인 부정정 보부재를 대상으로 표준화재온도곡선과 고온에서의 항복강도, 탄성계수 그리고 비열, 선팽창계수를 적용하는 해석적 방법을 통하여 내화성능을 평가하고, 이를 바탕으로 일반 구조용 강재에 의한 보부재의 내화성능 평가의 안전성을 확인하였다.

구조단열패널의 저에너지주택 적용을 위한 내화 및 단열성능 평가 (Fire Resistance Performance and Thermal Performance Evaluation of Structural Insulated Panels for Low-Energy Houses)

  • 이현주;나환선;이철희;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권2호
    • /
    • pp.36-46
    • /
    • 2012
  • Structure Insulated Panel (SIP) is an wooden structure material with which structure and insulation functions are satisfied. Hence, it would be a cost-effective model to implement low energy house which has higher insulation and structure performance and which the wall thickness is able to be reduced. In this study, performance of thermal insulation and fire resistance were evaluated in order to verify applicability to low energy house. Fire resistance test is performed on vertical load bearing members for partitions, and the test results satisfy one hour of fire resistance condition according to KS F 2257. The members include two layers of fireproof gypsum board with thicknesses of 12.5mm attached to SIP. Thermal insulation performance is satisfied with the 2012 standard ($0.225W/m^2{\cdot}K$). As the performance of resistance and thermal insulation are satisfied, SIP is expected to be applied to low energy building materials. In the future, the structural safety will be confirmed by structural performance and seismic performance test and the guidelines for distribution will be drawn up.

폭렬 현상을 고려한 RC 구조물의 PBD기반 구조내화설계 기술개발에 관한 연구(III) -일본의 내화안전성평가기법을 활용한 사례조사 연구- (A Study on the Structural Fire Resistance Performance Design of RC Structural according to the Explosive Spalling - A Case Study on the Evaluation Method of Structural Fire Resistance in Japan -)

  • 김세종;이재영;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.310-315
    • /
    • 2008
  • The objective of design for a post flash-over fire is contain the fire and prevent structural collapse, as necessary to meet the performance requirements. In the post flash-over phase of a fire all of the combustible objects in the compartment are burning and the heat release rate is limited either by the fuel surface area or the available air supply. So for the PBD situations, the process of evaluation method for fire phenomena is very important. It is the aim of this study to investigate and analyze the evaluation method of structural fire resistance in Japan.

  • PDF

Ansys를 활용한 플랜트 시설물 내화성능에 대한 해석적 연구 (Analytical Study of Fire Resistance Performance of Plant Facilities using Ansys)

  • 최두찬;양민혁;오수민;양소진
    • 한국재난정보학회 논문집
    • /
    • 제19권4호
    • /
    • pp.958-967
    • /
    • 2023
  • 연구목적: 본 연구는 화재위험도가 높은 플랜트 시설물에 적용하고 있는 국내 내화성능을 분석하고 적합한 내화저항성능을 확보하여 플랜트 시설물의 화재 안전성을 확보하고자 한다. 연구방법:유한요소해석 프로그램인 Ansys를 활용하여 화재하중과 내화피복을 변수로 열전달 해석과 구조해석을 수행하고 해석 결과에 따른 플랜트 시설물의 내화성능을 분석하였다. 연구결과: 국내 플랜트 시설물에 적용된 내화피복은 UL 1709에 제시된 탄화수소화재의 화재하중을 적용하였을 때 내화성능을 확보하지 못하였으며 화재 후 강재의 변형 또한 크게 나타남을 확인하였다. 결론:현재 플랜트 시설물에 적용된 국내의 내화성능은 석유화학 플랜트 등과 같이 급격한 화재성장과 큰 화재하중에서 내화성능을 확보할 수 없으며 플랜트 시설물의 성능평가를 통해 적합한 내화성능을 평가하여 화재 안전성을 확보하여야 한다.

온도해석과 재하가열시험에 의한 콘크리트 충전 보부재의 내화성능평가에 관한 연구 (Study on Fire Resistance of Beams filled with Concrete at Web Through Temperature Analysis and Load-bearing Fire Tests)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.82-88
    • /
    • 2010
  • 건축 구조물의 주요 구조부는 중력하중의 전달과 수평하중을 견디도록 설계, 시공되어야 함을 물론이고, 화재의 고열환경에서 부수적으로 발생되는 온도에 의한 추가하중을 지지하도록 설계되어야 한다. 강구조 건축물에서의 보부재는 중력 및 횡력 방향의 하중에 더 강한 지지력을 확보하기 위하여 H형강 웨브부분에 콘크리트를 충전하는 타입의 개발 및 적용이 이루어져 왔으나, 내화성능의 평가는 거의 이루어지지 않은 상태이다. 따라서 본 논문에서는 H형강 보부재의 웨브에 일반강도의 콘크리트로 충전된 시험체를 대상으로 열전도 해석에 의한 내화성능과 재하가열시험을 통한 내화성능을 각각 제시하고 상관성을 비교분석하였다.

주거용 내화단면 중공슬래브의 휨거동 평가 (A Evaluation on Flexural Behavior for Hollow Core Slab of Fire Resistance section for Residence Building)

  • 부윤섭;배규웅;신상민
    • 한국공간구조학회논문집
    • /
    • 제23권2호
    • /
    • pp.61-68
    • /
    • 2023
  • A two-hour fire-resistance PC hollow slab for residential use was developed to secure structural and fire-resistance performance and to be applied to the general building and apartment housing markets. Compared to the existing hollow slab, in order to secure the same or better structural performance and economic feasibility by reducing the quantity, it was attempted to secure the fire resistance performance by reducing the concrete filling rate in the cross section and adjusting the thickness of the upper and lower flanges by optimizing the hollow shape in the cross section of the slab. For structural performance evaluation, experiments were performed on PC hollow slabs by varying the member thickness and the presence or absence of overlaid concrete, and all of the experimental results showed that the design strength was sufficiently exhibited and that stability during construction was possible. The developed synthetic PC hollow slab has secured fire resistance and residential performance so that it can be applied to all buildings, and it is intended to be immediately applied to the field.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

용접구조용 강재 적용 대형 보부재의 내화성능 연구 (Study of Fire Resistance for Long Span Beams Made of Submarine Structural Steels)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.149-150
    • /
    • 2015
  • Structural beam plays a key role to carry the applied load on the floors. And then the beam have to sustain the applied load and its load-bearing capacity in fire situation. In this study to know the fire resistance performance of long span beam made of a submarine structural steels, an engineering method is used using mechanical and thermal properties of structural steel at high temperature.

  • PDF