Investigation of vibration and stability of cracked columns under axial load

  • Ghaderi, Masoud;Ghaffarzadeh, Hosein;Maleki, Vahid A.
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1181-1192
    • /
    • 2015
  • In this paper, an analytical method is proposed to study the effect of crack and axial load on vibration behavior and stability of the cracked columns. Using the local flexibility model, the crack has been simulated by a torsional spring with connecting two segments of column in crack location. By solving governing eigenvalue equation, the effects of crack parameters and axial load on the natural frequencies and buckling load as well as buckling load are investigated. The results show that the presents of crack cause to reduction in natural frequencies and buckling load whereas this reduction is affected by the location and depth of the crack. Furthermore, the tensile and compressive axial load increase and decrease the natural frequencies, respectively. In addition, as the compression load approaches to certain value, the fundamental natural frequency reaches zero and instability occurs. The accuracy of the model is validated through the experimental data reported in the literature.

The Effect of Out-of-Plane Load on the In-Plane Shear Capacity of Reinforcement Concrete Shear Wall (철근 콘크리트 전단벽에서 면외 하중이 면내 전단성능에 미치는 영향)

  • Shin, Hye Min;Park, Jun Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.77-83
    • /
    • 2024
  • The design shear strength equations of RC shear walls have been developed based on their performance under in-plane (IP) loads, thereby failing to account for the potential performance degradation of shear strength when subjected to simultaneous out-of-plane (OOP) loading. Most of the previous experimental studies on RC walls have been conducted in one direction under quasi-static conditions, and due to the difficulty in experimental planning, there is a lack of research on cyclic loading and results under multi-axial loading conditions. During an earthquake, shear walls may yield earlier than their design strength or fail unexpectedly when subjected to multi-directional forces, deviating from their intended failure mode. In this paper, nonlinear analysis in finite element models was performed based on the results of cyclic loading experiments on reinforced concrete shear walls of auxiliary buildings. To investigate the reduction trend in IP shear capacity concerning the OOP load ratio, parametric analysis was conducted using the shear wall FEM. The analysis results showed that as the magnitude of the OOP load increased, the IP strength decreased, with a more significant effect observed as the size of the opening increased. Thus, the necessity to incorporate this strength reduction as a factor for the OOP load effect in the wall design strength equation should be discussed by performing various parametric studies.

The vessel collision load on bridge with fender system (방호공을 고려한 선박의 충돌하중)

  • 이계희;고재용;이성로
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.193-200
    • /
    • 2004
  • In this study, the impact load on bridge by vessel collision in consideration of fender system is evaluated by numerical method. The bow of object vessel(DWT5000) is standardized, and modeled by shell elements. The main body of objective vessel is modeled by beam elements that present mass distribution and stiffness of vessel. The buoyancy effect of vessel is considered as linear spring. The two types of fender systems, such as steel and rubber are analyzed in this study. In steel fender system, the steel plates that absorb collision energy by its collapse are modeled by shell element with stiffener. The steel is material modeled elastic-plastic material. In the rubber fender system, the rubber material is modeled hyper-elastic material and the main body of fender is modeled by solid elements. The global impact responses of vessel and fender system are evaluated by explicit dynamic scheme. The results show that the magnitude of vessel collision force are depended on the material behavior of fender system. Also the values of collision load are conservative compare to the those of design codes.

  • PDF

Reliability Based Assessment of Safety and Load Carrying Capacity of Cable-Stayed Bridge under Vehicle Traffic Loads (차량 통행하중에 대한 사장교의 신뢰성에 기초한 안전도 및 내하력평가)

  • 조효남;이승재;임종권
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.04a
    • /
    • pp.199-208
    • /
    • 1994
  • One of the main objectives of the study is to propose a practical but realistic limit state model considering combined effect of axial and bending load for reliability analysis and safety assessment of cable-stayed bridge under vehicle traffic loads. This paper is intended to propose a new approach for the evaluation of reserved load carrying capacity of cable-stayed bridge under vehicle traffic loads in terms of equivalent strength, which may be defined as a bridge strength corresponding to the reliability index of the bridge. This can be derived from an inverse process based on the concept of FOSM form of reliability index. AFOSM and IST methods are used for the reliability analysis of the proposed models. The proposed reliability model and methods are applied to the safety assessment of Jindo Bridge which is one of major two cable-stayed bridges in Korea.

  • PDF

A curvature method for beam-column with different materials and arbitrary cross-section shapes

  • Song, Xiaobin
    • Structural Engineering and Mechanics
    • /
    • v.43 no.2
    • /
    • pp.147-161
    • /
    • 2012
  • This paper presents a curvature method for analysis of beam-columns with different materials and arbitrary cross-section shapes and subjected to combined biaxial moments and axial load. Both material and geometric nonlinearities (the p-delta effect in this case) were incorporated. The proposed method considers biaxial curvatures and uniform normal strains of discrete cross-sections of beam-columns as basic unknowns, and seeks for a solution of the column deflection curve that satisfies force equilibrium conditions. A piecewise representation of the beam-column deflection curve is constructed based on the curvatures and angles of rotation of the segmented cross-sections. The resulting bending moments were evaluated based on the deformed column shape and the axial load. The moment curvature relationship and the beam-column deflection calculation are presented in matrix form and the Newton-Raphson method is employed to ensure fast and stable convergence. Comparison with results of analytic solutions and eccentric compression tests of wood beam-columns implies that this method is reliable and effective for beam-columns subjected to eccentric compression load, lateral bracings and complex boundary conditions.

Structural Performance of Cast-In-Place Infill Wall Frames using High Performance Fiber Reinforced Cement Composites (고인성 시멘트 복합재료를 사용한 현장타설 끼움벽 골조의 고조성능)

  • Lee Hye Yeon;Kim Sun Woo;Park Wan-Shin;Lee Gab-Won;Choi Chang Sik;Yun Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.275-278
    • /
    • 2005
  • High performance fiber reinforced cement composites(HPFRCCs) is a class of high ductile fiber reinforced cementitious composites developed for applications in the sensitive construction industry. HPFRCCs has undergone major evolution in both materials development and the range of emerging applications. This paper is to evaluate structural strengthening performance of LRCF(Lightly reinforced concrete frame) using the HPFRCCs. The experimental results, as expected, show that the crack load, yield load, and limited load are superior for specimen with HPFRCCs infill wall due to crosslink effect of fibers in concrete.

  • PDF

A Study on the Bifurcation Characteristics of Hybrid Cable Domes under Axisymmetric Load (축대칭 하중을 받는 Hybrid 케이블 돔의 Bifurcation 특성에 관한 연구)

  • 김승덕;백인성;김형석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.277-284
    • /
    • 2003
  • One of important problem, in large space structure, is to overcome the self-weight of roof structure. This problem can be solved with using tension members effectively. Thus the rapid progress of hybrid structure, that makes effective use of the means of settling, has a good effect on realizing the large space. These systems of hybrid structure have the advantages of light weight and its own internal redundancy, but are occurred unstable phenomenon such as bifurcation or snap-through buckling, when the load level is come to the critical point. Among the hybrid structure, cable dome is shown the strong nonlinearity of unstable phenomenon in accordance with the external force. Therefore, the purpose of this study is to analyze and verify comparatively the unstable phenomenon of the Geiger and Flower type cable dome structures under axismmetric load.

  • PDF

Behaviour of guyed transmission line structures under downburst wind loading

  • Shehata, A.Y.;El Damatty, A.A.
    • Wind and Structures
    • /
    • v.10 no.3
    • /
    • pp.249-268
    • /
    • 2007
  • Past experience indicates that the majority of failures of electrical transmission tower structures occurred during high intensity wind events, such as downbursts. The wind load distribution associated with these localized events is different than the boundary layer wind profile that is typically used in the design of structures. To the best of the authors' knowledge, this study represents the first comprehensive investigation that assesses the effect of varying the downburst parameters on the structural performance of a transmission line structure. The study focuses on a guyed tower structure and is conducted numerically using, as a case study, one of the towers that failed in Manitoba, Canada, during a downburst event in 1996. The study provides an insight about the spatial and time variation of the downburst wind field. It also assesses the variation of the tower members' internal forces with the downburst parameters. Finally, the structural behaviour of the tower under critical downburst configurations is described and is compared to that resulting from the boundary layer normal wind load conditions.

Seismic performance of lateral load resisting systems

  • Subramanian, K.;Velayutham, M.
    • Structural Engineering and Mechanics
    • /
    • v.51 no.3
    • /
    • pp.487-502
    • /
    • 2014
  • In buildings structures, the flexural stiffness reduction of beams and columns due to concrete cracking plays an important role in the nonlinear load-deformation response of reinforced concrete structures under service loads. Most Seismic Design Codes do not precise effective stiffness to be used in seismic analysis for structures of reinforced concrete elements, therefore uncracked section properties are usually considered in computing structural stiffness. But, uncracked stiffness will never be fully recovered during or after seismic response. In the present study, the effect of concrete cracking on the lateral response of structure has been taken into account. Totally 120 cases of 3 Dimensional Dynamic Analysis which considers the real and accidental torsional effects are performed using ETABS to determine the effective structural system across the height, which ensures the performance and the economic dimensions that achieve the saving in concrete and steel amounts thus achieve lower cost. The result findings exhibits that the dual system was the most efficient lateral load resisting system based on deflection criterion, as they yielded the least values of lateral displacements and inter-storey drifts. The shear wall system was the most economical lateral load resisting compared to moment resisting frame and dual system but they yielded the large values of lateral displacements in top storeys. Wall systems executes tremendous stiffness at the lower levels of the building, while moment frames typically restrain considerable deformations and provide significant energy dissipation under inelastic deformations at the upper levels. Cracking found to be more impact over moment resisting frames compared to the Shear wall systems. The behavior of various lateral load resisting systems with respect to time period, mode shapes, storey drift etc. are discussed in detail.

Calculation of Blast Load Including Interior Explosion Effects (실내폭발 효과를 포함한 폭발하중 산정)

  • Kim, Seong-Hwan;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.191-198
    • /
    • 2017
  • To study the behavior of structures subject to blast loads it is important to calculate the loads due to the explosives accurately, especially in the case of interior explosions. It is known that numerical method based on computational fluid dynamics can estimate relatively accurate blast load due to the interior explosion including reflection effect. However, the numerical method has disadvantages that it is difficult to model the analysis and it takes much time to analyze it. Therefore, in this study, the analytical method which can include the reflection effect of the interior explosion was studied. The target structures were set as the slabs of residential buildings subject to interior explosion that could lead to massive casualties and progressive collapses. First, the numerical method is used to investigate the interior explosion effect and the maximum deflection of the slab which was assumed to be elastic, and compared with the analytical method proposed in this study. In the proposed analytical method, we determine the weighting factor of the reflection effect using the beam theory so that the explosion load calculation method becomes more accurate.