• Title/Summary/Keyword: structural fire behavior

Search Result 136, Processing Time 0.027 seconds

A Study on the Investigation of Users Guide of One-Way Coupled Analysis for Performance-Based Structural Fire Resistance Design (성능기반 구조내화설계를 위한 단방향 연성해석 사용자가이드 조사에 관한 연구)

  • Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.96-97
    • /
    • 2021
  • In the Building Act, performance-based fire safety design is being promoted for institutionalization. The behavior of the structure against fire conditions can be predicted by using the advanced numerical analysis method based on the FEM (Finite Element Method) to predict the entire structural behavior including the behavior of the structure, but there is a limit to expressing the fire properties of the space and predicting the fire properties It is difficult to determine the variables to be transmitted to the FEM (Finite Element Method) model from the fire simulation results using FDS (Fire Dynamics Simulator). Accordingly, the purpose of this study is to introduce the code user's manual for FDS and FEM unidirectional coupling analysis.

  • PDF

Structural Behavior of Fire-Damaged Reinforced Concrete Beam with Normal Strength Concrete (화재 피해를 입은 일반 강도 철근콘크리트 휨부재의 구조 거동)

  • 이소진;신영수;이차돈;홍성걸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.307-312
    • /
    • 2002
  • This paper deals with structural behavior of reinforced concrete beams under fire and fire damaged condition. The main purpose of this study is to investigate the structural behavior of the beams under high temperature condition and to evaluate the remaining strength of flexural members by exposure time to fire. For this purpose, twelve beam specimens are fabricated and experimented. Ten specimens are exposed to the fire for 1 and 2 hours and to the failure. After being cooled in room temperature, the specimens are loaded to the failure. The research result shows that the main variables of the test, concrete cover and exposure time to fire are much influenced on the structural behavior and the remaining strength.

  • PDF

Fire-after-earthquake resistance of steel structures using rotational capacity limits

  • Pantousa, Daphne;Mistakidis, Euripidis
    • Earthquakes and Structures
    • /
    • v.10 no.4
    • /
    • pp.867-891
    • /
    • 2016
  • This paper addresses numerically the behavior of steel structures under Fire-after-Earthquake (FAE) loading. The study is focused on a four-storey library building and takes into account the damage that is induced in structural members due to earthquake. The basic objective is the assessment of both the fire-behavior and the fire-resistance of the structure in the case where the structure is damaged due to earthquake. The combined FAE scenarios involve two different stages: during the first stage, the structure is subjected to the ground motion record, while in the second stage the fire occurs. Different time-acceleration records are examined, each scaled to multiple levels of the Peak Ground Acceleration (PGA) in order to represent more severe earthquakes with lower probability of occurrence. In order to study in a systematic manner the behavior of the structure for the various FAE scenarios, a two-dimensional beam finite element model is developed, using the non-linear finite element analysis code MSC-MARC. The fire resistance of the structure is determined using rotational limits based on the ductility of structural members that are subjected to fire. These limits are temperature dependent and take into account the level of the structural damage at the end of the earthquake and the effect of geometric initial imperfections of structural members.

Structural Behavior of Fire-Damaged Reinforced Concrete Beam with High Strength Concrete (화재 피해를 입은 고 강도 철근콘크리트 휨 부재의 구조 거동)

  • 신미경;신영수;이차돈;홍성걸;이은주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.635-638
    • /
    • 2003
  • This paper deals with structural behavior of reinforced concrete beams with high strength under fire and fire damaged condition. The main purpose of this study is to evaluate the residual strength of flexural members by exposure time to fire. For this purpose, six beam specimens are fabricated and experimented. Among the specimens, four specimens are exposed to the fire for 60 and 90 minutes and two specimens are control beam that is not exposed to fire. After being cooled in room temperature, the specimens are loaded to the failure. The research result shows that the main variables of the test, concrete cover and exposure time to fire are much influenced on the structural behavior and the residual strength.

  • PDF

A Study on Fire Resisting Construction Design in Advanced Nation (선진각국의 내화설계법에 관한 연구)

  • 김화중
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.17-30
    • /
    • 1988
  • In Our Country, the fire safety design is done by the standard furnace fire test. This is haphazard procedure, as the standard furnace fire endurance of structural elements has little relation to the structural element endurance in an actual Compartment fire. The standard furnace fire test results, though obtained at great cost, do not contribute to the understanding of the behavior of structural elements in an elevated temperature environment and can not be applied rationally in fire safety design. The response of a steel and reinforced concrete structure in fire is a very complex problem. Therefore, in this paper is explained about tendency of study for fire safety design in advanced nations.

  • PDF

Fire Behavior of Steel Columns Encased by Damaged Spray-applied Fire Resistive Material

  • Kwak, Yoon Keun;Pessiki, Stephen;Kwon, Kihyon
    • Architectural research
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • A Steel column with damaged spray-applied fire resistive material (SFRM) may exhibit reduced structural performance due to the effects of elevated temperature during fire events. Thus, the fire load behavior of steel columns with removed or reduced SFRM needs to be examined to predict the structural damage by fire. FEM analyses were performed for the flange thinning removal models in which the SFRM was reduced as a constant strip in thickness at the top flange of the column. The temperature results for all models obtained from the heat transfer analyses were included as an initial condition in the FEM structural analyses. In this study, the results of analysis show that even small remnants of SFRM led to an effective reduction of temperature at any given fire duration, and improved significantly the axial load capacity of a column as compared to the complete removal cases of SFRM.

Structural Behavior of Retrofitted RC beams with Fire Damages (화재 피해를 입은 일반강도 RC 보의 보수성능)

  • 안주희;신영수;이차돈;홍성걸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1013-1016
    • /
    • 2003
  • This paper is to evaluate practically the techniques and materials of repair for RC elements with fire damages as well as to investigate the structural behavior of RC beams according to pre- or post-repair after fire-damages. For this purpose, normal concrete flexural specimens were exposed to high temperatures by the ISO 834 specification. After natural cooling and post-fire-curing in a natural environment for 2 months, the specimens were repaired with polymer cement mortar for 1 month curing.

  • PDF

A Study on the Fire Resistance Capacity of Slimfloor Beam with Asymmetric H Beam (비대칭 H형강을 사용한 슬림플로어 보의 내화성능에 관한 연구)

  • Han, Sang Hoon;Choi, Seng Kwan;Kim, Hee Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.357-366
    • /
    • 2007
  • This paper is a pilot study regarding an experimental and parametric study to investigate the structural behavior of slimfloor beam(ASB) in fire. The objective of this research is to obtain the rational fire resistance design method through understanding the structural behavior of composite members in fire. The flexural capacity of slimfloor section under various thermal conditions is examined on a basis of the strength retention of the materials at elevated temperatures and full bonding assumption. The effect of web thickness and ASB depth to the moment capacity in fire is also examined.

Effect of cooling rate on the post-fire behavior of CFST column

  • Afaghi-Darabi, Alireza;Abdollahzadeh, Gholamreza
    • Computers and Concrete
    • /
    • v.23 no.4
    • /
    • pp.281-294
    • /
    • 2019
  • The post-fire behavior of structural elements and the cooling process has always been one of the main concerns of the structural engineers. The structures can be cooled at different rates, where they affect the structure's behavior. In the present study, a numerical model has been developed using the Abaqus program to investigate the effect of cooling rate on the post-fire behavior of the CFST column. To verify the model, results of an experimental study performed on CFST columns within a full heating and cooling cycle have been used. In this model, coMParison of the residual strength has been employed in order to examine the behavior of CFST column under different cooling rates. Furthermore, a parametric study was carried out on the strength of steel and concrete, the height of the specimens, the axial load ratio and the cross-sectional shape of the specimen through the proposed model. It was observed that the cooling rate affects the behavior of the column after the fire, and thus the higher the specimen's temperature is, the more effect it has on the behavior. It was also noticed that water cooling had slightly more residual strength than natural cooling. Furthermore, it was recognized from the parametric study, that by increasing the strength of steel and concrete and the load ratio, as well as modifying the cross-sectional shape from circular to square, residual strength of column at the cooling phase was less than that of the heating phase. In addition, with reducing column height, no change was witnessed in the column behavior after the cooling phase.

Study on the Effective Method of Fire Protection Technology in Railway Tunnel Fire (철도터널 내화성능 기술개발을 위한 내화성능 확보방안에 관한 연구)

  • Park, Kyung-Hoon;Kim, Heung-Yeol;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.86-91
    • /
    • 2010
  • In event of a tunnel fire, all kinds of equipment can be destroyed in high temperature that can exceed $1300^{\circ}C$, fatal structural demage can be caused by spalling of concrete structural elements. To make matters worse, there is a high possibility of the secondary damage which can lead to the collapse of the shear resisting structure. Accordingly, it is time that we developed the technology to counter fires in connection with the fire-resistant design of a tunnel structure. To secure the reliability of the fire-resistance performance of a tunnel structure, it is necessary to assess the fire's behavior on every structural element exposed to the fire as well as to calculate the tunnel fire intensity and the quantity of heat released. In this study, we drew out the fire damage range of each structural element of a tunnel and the minimum thickness of concrete cover for each fire-resistant material through some actual experiments of fire behavior on the structural elements of a tunnel.