Browse > Article

A Study on the Fire Resistance Capacity of Slimfloor Beam with Asymmetric H Beam  

Han, Sang Hoon (한국건설기술연구원 화재및설비연구센터)
Choi, Seng Kwan (한국건설기술연구원 화재및설비연구센터)
Kim, Hee Ju (한국건설기술연구원 화재및설비연구센터)
Publication Information
Journal of Korean Society of Steel Construction / v.19, no.4, 2007 , pp. 357-366 More about this Journal
Abstract
This paper is a pilot study regarding an experimental and parametric study to investigate the structural behavior of slimfloor beam(ASB) in fire. The objective of this research is to obtain the rational fire resistance design method through understanding the structural behavior of composite members in fire. The flexural capacity of slimfloor section under various thermal conditions is examined on a basis of the strength retention of the materials at elevated temperatures and full bonding assumption. The effect of web thickness and ASB depth to the moment capacity in fire is also examined.
Keywords
asymmetric slimfloor beam; structural fire behavior; heat transfer analysis; flexural capacity; fire;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 B. Ellingwood and J. R. Shaver, Effects of Fire on Reinforced Concrete Members, Journal of the Structural Division, ASCE, Vol. 106, No. ST11, pp. 2151-2166, November 1980
2 ASTM E 119-83, Standard Methods of Fire Tests of Building Construction and Materials, American Society for Testing and Materials, 1985
3 Deric J. Oehlers, Mark A. Bradford, (1999), Elementary Behaviour of Composite Steel and Concrete Structural Members, Butterworth- Heinemann
4 대한건축학회, (1998), 강구조 한계상태 설계기준 및 해설
5 ACI 216R-89, Guide for Determining the Fire Endurance of Concrete Elements, 1989
6 The Steel Construction Institute, (1997), Design of Asymmetric Slimflor Beams using Deep Composite Decking, SCI P175
7 D. L. Mullett, (1998), Composite Floor Systems, Blackwell Science
8 The Steel Construction Institute, (1992), Slim Floor Design and Construction, SCI P110
9 R. Felicetti and P. G. Gambarova, Effects of High Temperature on the Residual Compressive Strength of High-Strength Siliceous Concretes, ACI Materials Journal, Vol. 95, No. 4, pp. 395-406, 1998
10 J. C. Dotreppe, J. M. Franssen and Y. Vanderzeypen, Calculation Method for Design of Reinforced Concrete Columns under Fire Conditions, ACI Structural Journal, January-February 1999
11 이승재, 강성덕, 최승관, 김명한 김상대, (2006), iTECH 합성 보의 내화성능에 대한 실험연구, 한국강구조학회 논문집, 제 18권 2호, pp. 643-653
12 허병욱, 배규웅, 문태섭, (2004), 매입형(슬림플로어) 합성보의 휨성능 평가, 한국강구조학회 논문집, 제 16권 2호, pp. 235-245
13 P. K. Mehta and P. J. M. Monteiro, Concrete- Structure, properties and Materials, 2nd Edition, Prentice Hall, 1993
14 D. Hosser, T. Dorn and O. El-Nesr, Experimental and Numerical Studies of Composite Beams Exposed to Fire, Journal of Structural Engineering, Vol. 120, No. 10, October 1994
15 김성배, 최승관, 이창남, 김상섭, (2006), TSC 합성보의 내화 성능에 관한 연구, 제 18권 1호, pp. 113-122
16 Association of Specialist Fire Protection Contractors and Manufacturers Limited, (1992) Fire protection for structural steel in buildings, 2nd ed
17 대한건축학회, (2005), 건축구조설계기준, pp395-452
18 CEB/FIP, Structural Concrete-Textbook on Behaviour, Design and Performance, International Federation for Structural Concrete(fib), 1999
19 Y.C. Wang, (1998), Deflection of Steel-concrete Composite Beams with Partial Shear Insteraction, Joural of Structural Engineering
20 American Institute of Steel Construction(AISC), (1993), Load and resistance factor specification for structural steel buildings