• 제목/요약/키워드: stress waveform

검색결과 82건 처리시간 0.032초

A Cascaded Multilevel Inverter Using Bidirectional H-bridge Modules

  • Kang, Feel-Soon;Joung, Yeun-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.448-456
    • /
    • 2012
  • This paper presents a multilevel inverter configuration which is designed by insertion of a bidirectional switch between capacitive voltage sources and a conventional H-bridge module. The modified inverter can produce a better sinusoidal waveform by increasing the number of output voltage levels. By serial connection of two modified H-bridge modules, it is possible to produce 9 output voltage levels including zero. There are 24 basic switching patterns with the 9 output voltage levels. Among the patterns, we select the 2 most efficient switching patterns to get a lower switching loss and minimum dv/dt stress. We then analyze characteristics of Total Harmonic Distortion (THD) of the output voltage with variation of input voltage by computer-aided simulations and experiments.

상용 주파수용 단일 공진 PWM 인버터의 특성 (A Characteristic of commercial frequency unity Resonant PWM Inverter.)

  • 김종해;배상준;김경식;문창수;안항목
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.318-320
    • /
    • 1996
  • This paper describes a new dc/ac inverter system, which makes use of parallel loaded high frequency resonant inverter consisting of full bridge, for achieving sinusoidal ac waveform. Because current throughout switch at turn-on is always zero in proposed inverter, low stress and low switching loss is achieved. Operating characteristic of proposed system is analyzed in per unit system using computer simulation. Output voltage of it include low harmonics and almost close tn sine wave.

  • PDF

공진 DC-Link 인버터의 공진 초기전류의 보상에 관한 연구 (Resonance initial current compensation for Resonant DC-Link inverter)

  • 곽동걸;서기영;권순걸;이현우;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1136-1141
    • /
    • 1992
  • This paper proposes a control technique to obtain high frequency quasi sinusoidal DC-Link waveform permitting zero-voltage-switching(ZVS). This operation results in reduction of commutation stress and switching losses in the power devices because they cause no switching loss in principle. But in existing control methods, the resonant capacitor voltage is not frequently made of zero-cross oscillation. We propose an optimum control stratege which can sustain oscillation and keep the capacitor voltage at an allowable level. Some experimental results are included to confirm the validity of the analytical results.

  • PDF

Fluid-structure interactions of physiological flow in stenosed artery

  • Buriev, Bahtiyor;Kim, Tae-Dong;Seo, Tae-Won
    • Korea-Australia Rheology Journal
    • /
    • 제21권1호
    • /
    • pp.39-46
    • /
    • 2009
  • Atherosclerosis is a disease that narrows, thickens, hardens, and restructures a blood vessel due to substantial plaque deposit. The geometric models of the considered stenotic blood flow are three different types of constriction of cross-sectional area of blood vessel; 25%, 50%, and 75% of constriction. The computational model with the fluid-structure interaction is introduced to investigate the wall shear stresses, blood flow field and recirculation zone in the stenotic vessels. The velocity profile in a compliant stenotic artery with various constrictions is subjected to prescribed physiologic waveform. The computational simulations were performed, in which the physiological flow through a compliant axisymmetric stenotic blood vessel was solved using commercial software ADINA 8.4 developed by finite element method. We demonstrated comparisons of the wall shear stress with or without the fluid-structure interaction and their velocity profiles under the physiological flow condition in the compliant stenotic artery. The present results enhance our understanding of the hemodynamic characteristics in a compliant stenotic artery.

A Study on commercial frequency source with ZCS type high frequency resonant Inverter

  • Kim, Jong-hae;Kim, Dong-Hee;Bae, Sang-Jun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.1030-1035
    • /
    • 1998
  • This paper describes a new dc-ac inverter system, which for achieving sinusoidal ac waveform make use of parallel loaded frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. Since current through switches is always zero at its turn-on in proposed inverter, low stress and low switching loss is achieved. The theoretical analysis is proved through the experimental test.

  • PDF

전동차용 AC견인전동기 설계기술 (Design Technologies of AC Traction Motor for Rolling Stocks)

  • 배동진;이정일;김남해;김근웅;윤종학;이기호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.319-321
    • /
    • 1998
  • Some design technologies of AC traction motor for rolling stocks are presented. AC Traction motors for rolling stocks are operated in worst conditions such as frequent mechanical vibrations, compact design with limited mounting space, severe thermal stress at outside, driven with nonsinusoidal voltage waveform inverters, and so on. Therefore, design procedures must be carefully investigated in the viewpoint of theoritically and practical use. Design procedure contains, the motor size determination, electromagnetic circuit design, insulation system design, vibrations and thermal expansion of rotor bars, temperature rise, as well as output characteristics.

  • PDF

한국형 고속전철용 견인전동기 개발 (Development of the Traction Motor for High Speed Train)

  • 이상우;윤종학;최종묵;박계서
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.427-433
    • /
    • 2002
  • An inverter-driven induction motor is usually adapted to the traction motor for a high speed drive system requiring safety, reliability, performance, compact size owing to the space and weight alloted for attaching to train, etc. and AC Traction motor for G7 train will be operated in the worst condition such as mechanical vibration, limited mounting space, severe thermal stress, inverter with non-sinusoidal voltage waveform, dust and so on. therefore, design procedure must be carefully carried out wi th considering the motor size, vibration and thermal expansion of rotor bars, insulation system, reliability of frame, as well as output characteristics. In this paper, we will inform the characteristics and design of the traction motor for G7 train and also analyze the test result of it.

  • PDF

리벳구멍을 갖는 2024 알루미늄 합금의 피로 균열 진전 동안에 발생한 음향방출 파형 특성 (Characteristics of the Acoustic Emission Waveforms from the Fatigue Crack Propagation of 2024 Aluminum Alloy with Rivet Hole)

  • 남기우;안석환
    • 한국해양공학회지
    • /
    • 제15권1호
    • /
    • pp.52-56
    • /
    • 2001
  • This study were looks at the effect of the initial cut length or stress concentration level, on the wave forms produced by crack propagation. The signals were collected, then classified visually for each type of sample. They were put into three classes according to their shapes in the time and frequency domain. Each class should domain signals which could be correlated to a certain micro-failure mechanism that occurs during the fatigue process. Classes of these signals compared, with each sample. To see if there were any classes common to the three samples. The fatigue test attempted to determine if the initial cut length has any influence on the type of signals.

  • PDF

홀드 업 타임 보상회로를 가진 IT 기기용 Front-end PSFB DC/DC 컨버터 (Phase-Shifted Full Bridge(PSFB) DC/DC Converter with a Hold-up Time Compensation Circuit for Information Technology (IT) Devices)

  • 이강현
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.501-506
    • /
    • 2013
  • A hold-up time compensation circuit is proposed to get high efficiency of the front-end phase-shifted full bridge DC/DC converter. The proposed circuit can make the phase-shifted full bridge front-end DC/DC converter built with 0.5 duty ratio so that the conduction loss of the primary side and voltage stress across rectifier in the secondary side are reduced and the higher efficiency can be obtained. Furthermore, the requirement of an output filter significantly can diminish due to the perfect filtered waveform. A 12V/100A prototype has been made and experimental results are given to verify the theoretic analysis and detailed features.

Primary Current Generation for a Contactless Power Transfer System Using Free Oscillation and Energy Injection Control

  • Li, Hao Leo;Hu, Aiguo Patrick;Covic, Grant Anthony
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.256-263
    • /
    • 2011
  • This paper utilizes free oscillation and energy injection principles to generate and control the high frequency current in the primary track of a contactless power transfer system. Here the primary power inverter maintains natural resonance while ensuring near constant current magnitude in the primary track as required for multiple independent loads. Such energy injection controllers exhibit low switching frequency and achieve ZCS (Zero Current Switching) by detecting the high frequency current, thus the switching stress, power losses and EMI of the inverter are low. An example full bridge topology is investigated for a contactless power transfer system with multiple pickups. Theoretical analysis, simulation and experimental results show that the proposed system has a fast and smooth start-up transient response. The output track current is fully controllable with a sufficiently good waveform for contactless power transfer applications.