• 제목/요약/키워드: stress distribution function

검색결과 411건 처리시간 0.026초

인공치아에 있어 피질골의 두께 변화가 미치는 영향에 관한 연구 (A Numerical Study for the Variation of Cortical Bone Thickness with Several Dental Implants)

  • 최재봉;문항진;최귀원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.323-326
    • /
    • 1996
  • Dental implant is increasingly used to recover the mastication function of tooth. Several types of implant were designed to give an optimal stress distribution in surrounding bony regions. In this study, six types of implant were investigated using finite element method and it was studied i) how the variation of cortical bone thickness affects the stress distribution in surrounding bony regions depending upon implant types, ii) which type gives the best characteristics in the sence of stress distribution and stability. The hybrid-type implant with cylinder and screw gave the optimum properties in view of stability and response to the variation of cortical bone thickness.

  • PDF

Different estimation methods for the unit inverse exponentiated weibull distribution

  • Amal S Hassan;Reem S Alharbi
    • Communications for Statistical Applications and Methods
    • /
    • 제30권2호
    • /
    • pp.191-213
    • /
    • 2023
  • Unit distributions are frequently used in probability theory and statistics to depict meaningful variables having values between zero and one. Using convenient transformation, the unit inverse exponentiated weibull (UIEW) distribution, which is equally useful for modelling data on the unit interval, is proposed in this study. Quantile function, moments, incomplete moments, uncertainty measures, stochastic ordering, and stress-strength reliability are among the statistical properties provided for this distribution. To estimate the parameters associated to the recommended distribution, well-known estimation techniques including maximum likelihood, maximum product of spacings, least squares, weighted least squares, Cramer von Mises, Anderson-Darling, and Bayesian are utilised. Using simulated data, we compare how well the various estimators perform. According to the simulated outputs, the maximum product of spacing estimates has lower values of accuracy measures than alternative estimates in majority of situations. For two real datasets, the proposed model outperforms the beta, Kumaraswamy, unit Gompartz, unit Lomax and complementary unit weibull distributions based on various comparative indicators.

경사기능재료의 비정상 열응력에 관한 해석적 연구 (An analytical study on unsteady thermal stresses of functionally graded materials)

  • 최덕기;김창수
    • 대한기계학회논문집A
    • /
    • 제21권9호
    • /
    • pp.1441-1451
    • /
    • 1997
  • This paper addresses method which can be used for analyzing thermal stresses of a functionally graded material(FGM) using semi-analytical approach. FGM is a nonhomogeneous material whose composition changes continuously from a metal surface to a ceramic surface. An infinite one dimensional FGM plate is considered. The temperature distribution in the FGM is obtained by approximate Green's function solution. To expedite the convergence of the solutions, alternative Green's function solution is derived and shows good agreement with results from finite difference method. Thermal stresses are calculated using temperature distribution of the plate.

SCM415 침탄질화 처리재의 통계학적 피로거동에 대한 연구 (The Statistical study on the fatigue bebavior of Nitro -Carburized SCM415 steel)

  • 송삼홍;이상훈;임세혁
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.719-723
    • /
    • 1996
  • In this research, The statistical characteristics of non-heated and nitro-carburized specimens are investigated under two stress levels (1.15 .sigma. $_{w}$ .leq. .sigma.$_{\alpha}$ .leq. 1.25 .sigma. $_{w}$). Seven specimens of each stress level are tested by rotary bending fatigue machine. The cycles about each crack length and crack propagation rate are used as statistical variagle of weibull distribution. By using concept of reliability function, reliable S-N formula of Nitro-Carburized specimen are gotten.ten.

  • PDF

침탄질화 처리된 SCM415재의 피로거동에 대한 통계적 연구 (A Statistical Study on the Fatigue Behaviors of Nitro-Carburized SCM415)

  • 송삼홍;이상훈;임세혁
    • 한국정밀공학회지
    • /
    • 제14권5호
    • /
    • pp.128-133
    • /
    • 1997
  • Due to their high strength and good wear resistance, nitro-carburizing materials have been used for many machine components. However, the nitro-carburizing materials are found to have one disadvantage ; that is, their strength and fatigue life show larger scatter than those of non-heated metals. In this paper, therfore, the statistical chracteristics of non-heated and nitro-carburized specimens for SCM415 are investi- gated under two different of stress levels 1.15 .sigma. /sub .omega. / .leq. / .sigma. / sub .alpha. / .leq. / 1.25 .sigma. /sub .omega. /. Seven specimens at each stress level are tested by using rotating bending fatigue tester. The relation between a crack length and fatigue cycles can be arranged for Weibull distribution, and S-N curve using 95% reliability function is obtalined for nitro-carburized specimen.

  • PDF

단일치 임플란트에서 고정체와 지대주 직경의 차이에 따른 광탄성 응력 분석 (Photoelastic Stress Analysis of Single Implant Restoration According to Implant Fixture Size and Abutment Diameter)

  • 이진한;조혜원
    • 구강회복응용과학지
    • /
    • 제24권3호
    • /
    • pp.253-267
    • /
    • 2008
  • 이 연구의 목적은 임플란트 고정체와 지대주간의 직경 차이가 임플란트 지지조직에 발생하는 응력에 미치는 영향을 평가 하는 것이다. 본 연구에는 세 가지 직경(4.0, 5.0, 6.0㎜)의 3i 임플란트 고정체에 지대주의 직경을 달리하여 수복하고, 하중 조건(15, 30 lb)에 따라 임플란트 지지조직에 발생한 응력의 정도와 분포를 광탄성 응력 분석법을 이용하여 비교, 분석하였다. 연구결과 고정체의 직경이 증가할수록, 상부 보철물에 가해지는 하중에 대하여 고정체 변연부의 응력집중이 높게 나타났으며, 상부 보철물의 근원심 폭경을 증가시키는 것이나, 임플란트 고정체의 직경에 비해 작은 지대주를 사용하는 것은 고정체 주위의 응력양상에 영향을 주지 않았다.

골유착성 임프란트와 자연치를 이용한 고정성 국소의치에서 응력분산 및 충격흡수에 관한 유한요소법적 응력분석 (A FINITE ELEMENT STRESS ANALYSIS OF THE STRESS DISTRIBUTION AND THE SHOCK ABSORPTION IN AN OSSEOINTEGRATED IMPLANT-NATURAL TOOTH SUPPORTED FIXED PARTIAL DENTURE)

  • 정창모;이호용
    • 대한치과보철학회지
    • /
    • 제30권4호
    • /
    • pp.582-610
    • /
    • 1992
  • The long-term success of any dental implant is dependent upon the optimization of stresses which occur during oral function and parafunction. Especially, it has been suggested that there is an unique set of problems associated with joining an osseointegrated implant and a natural tooth with a fixed partial denture. For this particular case, although many literatures suggest different ways to avoid high stress concentrations on the bone surrounding the implant under static and dynamic loading conditions, but few studies on the biomechanical efficacy of each assertion have been reported. The purpose of this investigation was to evaluate the efficacies of clinically suggested methods on stress distribution under static load and shock absorption under dynamic load, using two dimensional finite element method. In FEM models of osseointegrated implant-natural tooth supported fixed partial dentures, calculations were made on the stresses in surrounding bone and on the deflections of abutments and superstructure, first, to compare the difference in stress distribution effects under static load by the flexure of fastening screw or prosthesis, or intramobile connector, and second, to compare the difference in the shock absorption effects under dynamic load by intramobile connector or occlusal veneering with composite resin. The results of this analysis suggest that : 1. Under static load condition, using an implant design with fastenign screw connecting implant abutment and prosthesis or increasing the flexibility of fastening screw, or increasing the flexibility of prosthesis led to the .increase in height of peak stresses in cortical bone surrounding the implant, and has little effect on stress change in bone around the natural tooth. 2. Under static load condition, intramobile connector caused the substantial decrease in stress concentration in cortical bone surrounding the implant and the slight increase in stress in bone around the natural tooth. 3. Under dynamic load condition, both intramobile connector and composite resin veneering showed shock absorption effect on bone surrounding the implant and composite resin veneering had a greater shock absorption effect than intramobile connector.

  • PDF

데이터베이스 시스템을 이용한 탄소강의 피로강도 및 수명분포 (A Study on the Fatigue Strength and Life Distribution of Carbon Steel Using the Database System)

  • 김정규;문준호;김도식
    • 한국강구조학회 논문집
    • /
    • 제10권1호통권34호
    • /
    • pp.37-45
    • /
    • 1998
  • 기계 및 구조물의 안전성과 신뢰성 평가를 위하여 금속재료의 피로강도 데이터베이스 시스템을 구축하고, 이를 이용하여 금속재료의 피로수명 분포특성을 검토하였다. 종속도를 이용하여 구성한 관계형 피로강도 데이터베이스 시스템은 일련의 데이터 관리 및 해석작업을 효율적으로 수행하였다. 또한 Robust 방법과 보상오차함수(complementary error function)를 이용한 3-파라미터 Weibull분포의 파라미터 추정법 및 비파손확률를 검토하기 위하여 제안된 새로운 기준식의 타당성을 검토하였다. 조합분포모델을 이용하여 부하응력비와 Weibull분포의 파라미터 항으로 나타낸 피로수명 분포식은 탄소강의 P-R-N 특성을 해석함에 있어서 좋은 결과를 보였다.

  • PDF

사람 소구치부위에서 주위골의 구조 및 밀도변화가 교합력에 의한 치아의 응력분포에 미치는 영향 (The effect of varying peripheral bone structure and bone density on the occlusal stress distribution of human premolar regions)

  • 서예준;심준성;이근우;정문규;이호용
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.7-15
    • /
    • 2003
  • This study used FEM(Finite Element method) based on micro-CT images to see the effects of occlusal force distribution with varying bone density and structure. the mandibular premolar region from human cadaver, thickness of 10mm was imaged using micro-CT. the cross sectional images were taken every $10{\mu}m$. these were reconstructed and the longitudinal image at the mid point of mesiodistal of the speciman was obtained for the specimen for the FEM. The stress disribution produced by a vertical force at 100N and 100N horizontal were analyzed by MSC Nastran FEM Package. according to the result of this study the occlusal force distribution depends on the structure of cancellus bone and for further information on the occlusal force distribution on the tooth and the surrounding structure requires further studies on cancellus bone structure. CEJ of all model show the highest peak and region whice meet teeth and bone show second high peak. Original model and cortical bone add model show different stress distribution. Stress distribution changed according to bone structures and densities.

골격적 성숙도의 차이에 따라 RME 사용시 나타나는 상악골 복합체의 변화 (Skeletal Changes Following Application of RME at Different Maturation Stages)

  • 한순기;정동화;차경석
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.373-384
    • /
    • 2007
  • The purpose of this study was to analyse the stress distribution on the craniofacial suture and cranium after application of RME. Twelve years and six months old boy and twenty years old adult male were chosen for taking computed-tomography for FEM. From DICOM visual information, it was processed by 3-dimensional image construction program Mimics 10.01. Hounsfield unit(HU) which shows gray scale of CT image is picked for revealing mechanical properties of each model. The models have been accomplished with various range of physical properties. After applying 5.0 mm expansion, the maxillary complex model was obeserved for analyzing displacement and stress distribution of the model. The amount of transverse expansion of child and adult maxilla is different according to its location. It appears that it decreases gradually with the distance from separation site. In child, maximum compressive stress located broad area in zygomatic buttress department and the ends of frontal process of maxilla, pterygoid plate, and bones surrounding orbit. However, in adult maximum compressive stress was located smaller area and the stres was higher than child.