• Title/Summary/Keyword: strengthening repair

Search Result 154, Processing Time 0.026 seconds

Study on Adhesive Strength of Polymer Modified Cement Mortar for Maintenance in Concrete Structure (콘크리트 구조물 보수용 폴리머시멘트 모르타르의 부착강도 특성에 관한 연구)

  • Park, Sang-Soon;Kim, Jung-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.128-135
    • /
    • 2010
  • Polymer-modified cement mortar(PCM) has been widely used for strengthening of the concrete structures due to its excellent physical properties such as high strength and durability. Adhesive strength or behavior, on the other hands, between PCM and concrete is very important in strengthening the concrete member using PCM. Therefore the adhesive failure mechanism between PCM and concrete should be fully verified and understood. This study was performed to evaluate adhesive strength of PCM to the concrete by the direct pull-out test. In the direct pull-out tests, the adhesive strength under the various pre-treatment conditions such as immersion, thunder shower, freezing and thawing are evaluated. Also, the field direct pull-out test are performed to investigate the adhesive strength of mock-up test specimens. In the results of the test, the adhesive strength value by field test are lower than those of the standard curing condition. From these comparison and investigation, field test result was similar with the thunder shower test result. The results of the test was used to evaluate the korean industrial standard of polymer modified cement mortars for maintenance in concrete.

An Experimental Study on the Flexural Behavior of Slab Repaired and Reinforced with Strand and Polymer Mortar (강연선과 폴리머 모르타르에 의해 보수보강된 슬래브의 휨거동에 대한 실험적 고찰)

  • Yang Dong-Suk;Hwang Jeong-Ho;Park Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.171-177
    • /
    • 2005
  • Even though the cost associated with the repair and rehabilitation of existing structures are rapidly increasing, vast number of the repaired and rehabilitated structures do not function properly as expected during their remaining service lives. This paper focused on the flexural behavior of reinforced concrete slabs repaired and reinforced by PS strand and polymer mortar in the tension face. The slabs have the size of 700${\times}120{\times}$2200 m and 700${\times}120{\times}$1300 mm. Variables of experiment were space of strengthening, chipping, the number of strand, the kind of mortar in this experimental study. Attention is concentrated upon overall bending capacity, deflection, ductility and failure mode of repaired and reinforced slabs. Test results show that deflection of repaired and reinforced slabs reduced to approximately $40 \%$ comparison to standard slabs. Boundary cracking of chipping slab started ultimate load afterward. Concrete-mortar interface cracked 64.5 kN in repaired slab with AP mortar and 36.0 kN in repaired slab with general polymer mortar. Reinforcement effect increased with reducing space of strand. Also, Reinforcement effects are more by strand than by polymer mortar.

Experimental and Analytical Study on the Steel Beam bonded with CFRP Strip (레진으로 접착 보강한 강재보의 거동)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.81-88
    • /
    • 2017
  • In this paper, the behaviour of composite steel-CFRP members is studied experimentally and using FE-analysis. The use of advance composite materials in construction for repair and rehabilitation has become a frequent used method in the last decade. FRP composites have many advantages over the traditional technique of steel bonding for a number of reasons: 1. Composites add little or no additional weight to a building, eliminating the need for costly foundation strengthening. 2. FRP composites are very thin (1.2mm to 1.4mm). So there is no loss of floor space and negligible effect over the architectural aspect. 3. FRP composites do not corrode, this makes it long lasting. However, the method is yet to become a mainstream application due to a number of economical and design related issues. Brittle debonding failure, aging effect on bonding, broad based awareness and proper design guidelines are the main concern for future research works. This paper is focused on the ultimate load carrying capacity of the CFRP-strengthened beams and their effect on the deflection and failures modes by varying the amount of CFRP content.

Compressive and Adhesive Strengths of Mortars using Re-emulsification Type Polymer and Ultra-Rapid-Hardening Cement (재유화형 분말수지와 초속경 시멘트를 혼입한 모르타르의 압축강도 및 접착강도 특성)

  • Lee, Kwang-Il;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.329-335
    • /
    • 2018
  • The objective of this study is to develop a mortar mixture with high workability and adhesive strength for section jacketing in seismic strengthening technology of existing concrete structures. To achieve targeted requirements of the mortars (initial flow exceeding 200 mm, compressive strength of 30MPa, and adhesive strength exceeding 1MPa), step-by-step tests were conducted under the variation of the following mixture parameters: water-to-binder ratio, sand-to-binder ratio, polymer-to-binder ratio, dosage of viscosity agent, and content of ultra-rapid-hardening cement. The adhesive strength of the mortars was also estimated with respect to the various surface treatment states of existing concrete. Based on the test results, the mortar mixture with the polymer-to-binder ratio of 10% and the content of ultra-rapid-hardening cement of 5% can be recommended for the section jacketing materials. The recommended mortar mixture satisfied the targeted requirements as follows: initial flow of 220 mm, high-early strength gain, 28-day compressive strength of 35MPa, and adhesive strength exceeding 1.2MPa.

A Study on the Management and Utilization of Sub-Health Center in Rural area, Paraguay [1] - Focused on Limpio, Paraguay (파라과이 농촌지역 보건지소의 시설 관리 및 이용실태에 관한 연구[1] - 파라과이 림삐오시를 중심으로)

  • Kim, Ji Eon;Kim, Min Kyu;Nam, Eun Woo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.2
    • /
    • pp.7-17
    • /
    • 2020
  • Purpose: The purpose of this study is to identify the operational status and current management of Sub-Health Centers in Limpio, Paraguay. Second, understanding the use of Sub-Health Centers and Perceptions of Sub-Health Centers in Limpio, Paraguay. Third, Providing policy implications for strengthening the Health Delivery System in Paraguay. Methods: The survey of the current status of sub-health centers in Limpio was conducted with observation and interview. Utilization of Sub-Health centers was analyzed in the 2018 Paraguay Community Health Survey. A face to face interview was conducted to complete a questionnaire and 831 samples were collected for the study. Results: In order to perform the normal function of the sub-health center, it will be necessary to allocate manpower that meets the standard. A common problem with sub-health centers in Limpio is that they have an environment vulnerable to rain. Currently, there are no health promotion and communicable disease management programs in sub-health center. Satisfaction of users about treatment, equipment, medicines and cleanleness of rooms. Implications: First, it is necessary to allocate human resources and organize spaces according to the standard. Second, there was a problem caused by moisture, and continuous maintenance and repair are required. Third, water and sewage related facilities must be safely improved to prevent contamination of groundwater. Forth, it is necessary to implement a program that fits the role of the sub-health center. Fifth, it is necessary to form a health delivery system considering the accessibility of residents. Finally, it is necessary to discuss the location of sub-health center considering travel time of Limpio residents.

Return to Play of Elite Overhead Athletes with Superior Labral Anterior Posterior Tears only after Rehabilitation

  • Park, Jin Young;Hong, Kyung Ho;Lee, Jae Hyung;Oh, Kyung Soo;Chung, Seok Won;Jeon, Seung Hyub;Cha, Myung Joo
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.77-83
    • /
    • 2017
  • Background: Although there have been multiple reports on surgical outcomes of superior labral anterior to posterior (SLAP) lesions in overhead athletes, only a few reports exist in the literature about the results of nonoperative treatment in elite (collegiate or professional) overhead athletes. To determine the clinical outcomes of nonoperative treatment of SLAP lesions in elite overhead athletes. Methods: Between January 2006 and December 2011, 69 patients were selected. Initial arthroscopic SLAP repair was performed in 19 patients and of the 50 patients who underwent nonsurgical treatment, such as range of motion gain and periscapular muscle strengthening, 14 patients were converted to surgical treatment; 5 patients were lost to follow-up. Medical records of 31 elite overhead athletes who underwent nonsurgical treatment were retrospectively reviewed. Four clinical outcome measures were used: visual analogue scale (VAS) for pain, VAS for satisfaction, American Shoulder and Elbow Surgeons (ASES) score, and subjective feeling of recovery. Results: The average follow-up period was 35.9 months (range, 24-62 months). The VAS for pain decreased from 6.5 to 2.2 (p<0.01) and VAS for satisfaction was 7.6. The ASES score increased from 54.1 to 85.9 (p<0.01). The overall average value of subjective feeling of recovery was 72%. Twenty-three out of 31 elite athletes (74.2%) returned to play after rehabilitation; these 23 athletes performed at the same or higher levels after rehabilitation. Conclusions: Nonsurgical treatment in elite overhead athletes with SLAP lesion should be considered as a treatment option.

Flexural behaviour of reinforced low-strength concrete beams strengthened with CFRP plates

  • Boukhezar, Mohcene;Samai, Mohamed Laid;Mesbah, Habib Abdelhak;Houari, Hacene
    • Structural Engineering and Mechanics
    • /
    • v.47 no.6
    • /
    • pp.819-838
    • /
    • 2013
  • This paper summarises the results of an experimental study to investigate the flexural behaviour of reinforced concrete beams strengthened using carbon-fibre reinforced polymer (CFRP) laminate in four-point bending. The experimental parameters included are the reinforcing bar ratio ${\rho}_s$ and preload level. Four bar ratios were selected (${\rho}_s=0.13$ to 0.86%), representing the section of two longitudinal tensile reinforcements, with diameters of 8, 14, 16, and 20 mm in order to reveal the effect of bar ratio on failure load and failure mode. Eight beams that could be considered "full-scale" in size, measuring 200 mm in width, 400 mm in total height and 2300 mm in length, were tested. Three beams were selected with different bar ratios (${\rho}_1$, ${\rho}_2$, ${\rho}_3$), and considered as control specimens (without ), while three other beams identical to the control beams with the same CFRP laminates ratio and a seventh beam with ${\rho}_{min}$ (the lowest bar ratio) were also used. In the second part of the study, two beams with the bar ratio ${\rho}_2$ were preloaded at two levels, 50 and 100% of their ultimate loads, and then repaired. This experimental investigation was consolidated using an analytical model. The experimental and analytical results indicate that the flexional capacity and stiffness of strengthened and repaired beams using CFRP laminate were increased compared to those of control beams, and the behaviour of repaired beams was nearly similar to the undamaged and strengthened beams; unlike the ductility of strengthened beams, which was greatly reduced compared to the control.

Load carrying capacity of CFRP retrofitted broken concrete arch

  • Wang, Peng;Jiang, Meirong;Chen, Hailong;Jin, Fengnian;Zhou, Jiannan;Zheng, Qing;Fan, Hualin
    • Steel and Composite Structures
    • /
    • v.23 no.2
    • /
    • pp.187-194
    • /
    • 2017
  • To reuse a broken plain concrete (PC) arch, a retrofitting method was proposed to ensure excellent structural performances, in which carbon fiber reinforced polymers (CFRPs) were applied to repair and strengthen the damaged PC arch through bonding and wrapping techniques. Experiments were carried out to reveal the deformation and the load carrying capacity of the retrofitted composite arch. Based on the experiments, repairing and strengthening effects of the CFRP retrofitted broken arch were revealed. Simplified analysing model was suggested to predict the peak load of the CFRP retrofitted broken arch. According to the research, it is confirmed that absolutely broken PC arch can be completely repaired and reinforced, and even behaves more excellent than the intact PC arch when bonded together and strengthened with CFRP sheets. Using CFRP bonding/wrapping technique a novel efficient composite PC arch structure can be constructed, the comparison between rebar reinforced concrete (RC) arch and composite PC arch reveals that CFRP reinforcements can replace the function of steel bars in concrete arch.

Study on Crack Monitoring System in Steel Structure (강부재의 균열 모니터링에 관한 연구)

  • Lee, Jae-Sun;Chang, Kyong-Ho;Hwang, Jee-Hoon;Park, Hyun-Chan;Jeon, Jun-Tai;Kim, You-Chul
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.159-167
    • /
    • 2011
  • Steel structure construction is currently increasing on account of the many merits of steel structures. Due to numerous environmental factors, many cracks and extensive corrosion occur in steel structures, which cause the deterioration of the performance and life cycle of such structures. Maintenance of steel structures is thus strongly demanded, for safety control. The inspection methods that are currently being used, however, are very limited and can detect only local defects in steel structures. They also take much time to use and incur high maintenance costs. Moreover, such methods cannot be applied to huge steel structures, which men find unapproachable. They also require much time due to the need for periodic checks, and may lead to cost loss. Therefore, the development of a monitoring system that can detect defects in whole structures and can reduce the repair and strengthening costs at an early stage is very much needed. In this study, the generation and propagation of cracks were monitored via the electric-potential-drop method (EPDM).

Effects of Basalt Fiber on the Mechanical Properties of Secondary Barrier for LNG Cargo Containment System (현무암섬유를 이용한 LNG 화물창 2차 방벽의 기계적 특성에 대한 연구)

  • Woo-Seung Noh;Hae-Reum Shin;Seung-June Yeo;Man-Tae Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.207-212
    • /
    • 2024
  • Recently, with the strengthening of environmental regulations, there has been an increasing interest in eco-friendly energy sources, leading to a trend of the increasing scale of Cargo Containment Systems (CCS) for Liquefied Natural Gas (LNG) carriers. Among these systems, membrane tanks have gained popularity in LNG transport vessels due to their superior spatial utilization and competitiveness. However, due to high initial investment costs and the difficulty in repair in case of damage, a safety layer, the secondary barrier, must be installed without fail. In this study, in order to apply a new secondary barrier to the existing membrane-type LNG CCS, tests were conducted on the fiberglass layer previously used in the Triplex-Flexible Secondary Barrier (FSB), substituting it with basalt fiber. Tensile and vertical tensile tests were performed to assess the newly applied material. Environmental tests were conducted at room temperature (25℃) and extremely low temperatures (-170℃), considering the temperatures to which substances may be exposed during LNG vessel operations. The basalt-FSB produced in this study demonstrated superior results compared to the specifications of the existing product, confirming its potential applicability for implementation.