• 제목/요약/키워드: strength of resin denture base

검색결과 107건 처리시간 0.026초

Evaluation of polymethyl methacrylate resin mechanical properties with incorporated halloysite nanotubes

  • Abdallah, Reham M.
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.167-171
    • /
    • 2016
  • PURPOSE. This study inspects the effect of incorporating halloysite nanotubes (HNTs) into polymethyl methacrylate (PMMA) resin on its flexural strength, hardness, and Young's modulus. MATERIALS AND METHODS. Four groups of acrylic resin powder were prepared. One group without HNTs was used as a control group and the other three groups contained 0.3, 0.6 and 0.9 wt% HNTs. For each one, flexural strength, Young's modulus and hardness values were measured. One-way ANOVA and Tukey's test were used for comparison (P<.05). RESULTS. At lower concentration (0.3 wt%) of HNT, there was a significant increase of hardness values but no significant increase in both flexural strength and Young's modulus values of PMMA resin. In contrast, at higher concentration (0.6 and 0.9 wt%), there was a significant decrease in hardness values but no significant decrease in flexural strength and Young's modulus values compared to those of the control group. CONCLUSION. Addition of lower concentration of halloysite nanotubes to denture base materials could improve some of their mechanical properties. Improving the mechanical properties of acrylic resin base material could increase the patient satisfaction.

아크릴릭 레진 의치상 강화에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON REINFORCEMENT OF ACRYLIC RESIN DENTURE BASE)

  • 김형식;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제32권3호
    • /
    • pp.411-430
    • /
    • 1994
  • The denture may be fractured accidentally by an impact while outside the mouth, or may be cracked or broken while in service in the mouth. The latter is generally a fatigue failure caused by repeated flexure over a period of time. This investigation compared the flexural fatigue resistance, the impact force and the transverse strength of two denture base materials with and without the grid strengthener, the T300, the T800 and the Kevlar fiber to evaluate the fracture resistance. The distribution and behavior of fibers across fracture lines were examined by Hi-Scope Compact Microvision System. Through analyses of the data from this study, the following conclusions were obtained. 1. The flexural fatigue resistance, impact strength and transverse strength of high impact strength resin were higher than those of conventional heat polymerizing resin, but statistically there was no significant difference(p>0.05). 2. All specimens with and without the grid strengthener did not show significant differences in the flexural fatigue, the impact and the transverse strength test(p>0.05). 3. All specimens reinforced with the T300, the T800 and the Kevlar fiber showed significant increase of the fatigue resistance and the impact force(p<0.05). 4. All specimens reinforced with the T800 and the Kevlar fiber showed significant increase of the transverse strength(p<0.05). 5. All specimens reinforced with the T300, the T800 and the Kevlar fiber exhibited greenstick fractures. The fibers tended to remain enveloped in the resin, resisting pull-out.

  • PDF

수종 레진으로 의치상 조직면 개조시 의치상의 크기변화와 물리적 성질 및 표면상태 비교 연구 (AN EXPERIMENTAL STUDY ON THE DIMENSIONAL CHANGES OF RELINED DENTURES AND MECHANICAL PROPERTIES AND SURFACE TEXTURES OF SEVERAL RESINS USED IN DENTURE RELINING)

  • 이창한;김영수
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.25-41
    • /
    • 1990
  • The purpose of this study was to evaluate and compare the dimensional changes of relined dentures with a light-curing resin, a heat-curing resin, and a direct, hard reline resin. And also to measure the transverse strength, impact strength, surface hardness of the three resins used in relining. The surface textures of three resins also of evaluated by using scanning electron microscope. Through analyses on the data from this study, the following conclusions were obtained. 1. Impact strength of heat-curing resin was highest, and direct, hard reline resin higher, light-curing resin lowest. 2. Transverse strength of heat-curing resin was highest, and direct, hard reline resin and light-curing resin was lower and not signiicantly different. 3. Surface hardness of light-curing resin was lighest, heat-curing resin higher, and direct, hard reline resin was lowest. 4. After storage of the relined dentures for 1 day and 1 week in water at room temperature, linear shrinkage of distance between the reference points in the maxillary base relined with direct, hard reline resin was lowest, and those relined with light-curing resin and heat-curing resin were lower and were not significantly different. 5. After storage for 4 weeks in orator at room tempeature, linear shrinkage of distance between ridge crests of dentures relined with heat-curing resin was highest and that of distance between denture borders was not significantly different. 6. The dimensional changes of relined dentures during storage in water was not significant except those of distance between denture borders relined with light-curing resin at 1 day and 1 week storage in water. 7. At low magnification (x40) of SEM examination, the surface textures of three resins were similar except light-curing resin which had some defects. At high magnification (x200), the surface textures of hard, direct reline resin were smooth with little defects, but those of heat-curing resin and light-curing resin w ere irregular.

  • PDF

열가소성 의치상 레진과 첨상용 레진의 접착 강도에 저온플라즈마가 미치는 효과 (Nonthermal plasma on the shear bond strength of relining resin to thermoplastic denture base resin)

  • ;;송소연;박진홍;이정열;신상완
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.199-205
    • /
    • 2018
  • 목적: 이 연구는 저온 플라즈마가 자가중합형 재이장용 레진과 주입형 열가소성 의치상 레진의 결합 강도에 미치는 영향을 다른 표면 처리 방법에서 평가하기 위함이다. 재료 및 방법: 네 가지 열가소성 의치상이 이 연구에서 사용되었다: Acrylic Resin (Acrytone), Polyester (Estheshot-Bright), Polyamide (Valplast), Polypropylene (Weldenz)에 다양한 표면처리를 시행하였다: 대조군, 저온플라즈마, Sandblasting, Sandblasting와 저온플라즈마. 표면 처리 후 모든 시편은 Tokuyama Rebase II를 이용하여 원형의 테플론 관에 접착되었다. 전단강도는 Universal testing machine을 통해 crosshead speed 1 mm/min으로 측정되었다. 통계 분석 방법으로는 이원분산분석을, 사후 검정 방법으로는 Tukey's test가 사용되었다. 결과: Acrytone이 다른 열가소성 의치상 레진 그룹에 비하여 통계적으로 유의한 수준에서 더 높은 전단강도를 보인 반면 Weldenz는 가장 낮은 값을 나타냈다. Sandblast와 저온플라즈마를 순차적으로 시행한 조건에서 모든 레진 그룹 중 통계적으로 유의한 수준에서 가장 높은 전단강도 값을 나타냈다. 결론: 열경화성 의치상 레진과 재이장용 레진 사이의 전단강도에 저온플라즈마는 제한된 효과를 나타내었으며, sandblasting 처리와 함께 처리되었을 때 두 재료간 전단강도는 향상되었다.

타이타니움 의치상에 대한 다양한 금속표면처리제의 적용이 첨상레진과의 결합강도에 미치는 영향 (The Effects of Various Metal Surface Treatments on the Shear Bond Strength between Titanium Denture Base and Relined Resins)

  • 은준영;조인호;이종혁
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to evaluate the effect of various metal surface treatments on the shear bond strength between titanium denture base and relined resins. The surfaces of commercially pure(cp) titanium were sandblasted with $50{\mu}m$ $Al_2O_3$ for 20 seconds and each group was treated with MR $Bond^{(R)}$, Alloy $Primer^{(R)}$, and Super-Bond $C&B^{(R)}$ accordingly. The specimens were completed by application of relining resins. The specimens were stored in room temperature. And the shear bond strength of the specimens were measured with the MTS universal testing $machine^{(R)}$. The results were as follows: 1. In comparison with the relining materials, $Kooliner^{(R)}$ groups showed statistically higher shear bond strength than Tokuyama Rebase $II^{(R)}$ groups(p<0.05). 2. Comparing shear bond strength, according to surface treatment, Super-bond $C&B^{(R)}$ groups showed the highest bond strength and were significantly higher than the other three groups(p<0.05). Alloy $Primer^{(R)}$ groups showed no significant difference with the MR $Bond^{(R)}$ groups, but was significantly higher than the sandblasting-only groups(p<0.05). 3. Comparing surface treatment in each groups, for two types of relining resin, the group which applies $Kooliner^{(R)}$ and Super-bond $C&B^{(R)}$ showed the highest bond strength and showed significant difference compared to the other groups(p<0.05). When using Tokuyama Rebase $II^{(R)}$, Super-bond C&B group showed the highest bond strength, but there were no significant difference compared to the Alloy $Primer^{(R)}$ group. In this limited study, applying $Kooliner^{(R)}$ and Super-Bond $C&B^{(R)}$ after sandblasting is considered to be advantageous for relining of titanium base dentures.

광중합형 이장재와 금속의치상 간의 결합력에 관한 연구 (A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base)

  • 박인채;이준규;정재헌
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.161-170
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recomendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univasal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strengths than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strengths of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

적층가공과 절삭가공으로 제작한 의치상과 직접 첨상용 레진 간의 인장결합강도 비교 (Tensile bond strength of chairside reline resin to denture bases fabricated by subtractive and additive manufacturing)

  • 김효성;정지혜;배지명;김정미;김유리
    • 대한치과보철학회지
    • /
    • 제58권3호
    • /
    • pp.177-184
    • /
    • 2020
  • 목적:본 연구의 목적은 절삭가공과 적층가공으로 제작한 의치상과 직접 첨상용 레진과의 인장결합강도를 열중합형 의치상과 직접 첨상용 레진의 인장 결합강도와 비교 및 평가하여 절삭가공과 적층가공으로 제작한 의치상의 직접 첨상을 임상에 활용하고자 하는 것이다. 재료 및 방법:열중합형 의치상 레진(Lucitone 199), 절삭가공용 의치상 레진(VITA VIONIC BASE), 적층가공용 의치상 레진(NextDent Base)을 이용해 가로 25 mm × 세로 25 mm × 높이 3 mm의 직육면체 형태로 제작하였다. 제작한 의치상 레진 시편을 30일간 37℃ 증류수에 보관한 뒤, 건조하여 자가중합형 polyethyl methacrylate (PEMA) 직접 첨상용 레진(REBASE II Normal)을 사용해 결합하였다. 절삭가공과 적층가공용 의치상 레진을 실험군으로, 열중합형 의치상 레진을 대조군으로 설정하고 각 군 당 10개의 시편을 제작하였다. 모든 시편을 24시간 동안 37℃ 증류수에 보관한 뒤 꺼내어 만능시험기를 이용해 10 mm/min의 cross head speed로 인장결합강도를 측정하였고, 파절 양상을 관찰하여 접착 파절, 응집 파절, 혼합 파절로 분류하였다. 의치상의 제작 방법에 따른 직접 첨상용 레진과의 인장결합강도를 일원배치 분산분석으로 분석하였고 사후검정(Bonferroni's method)을 시행하였다 (α= .05). 결과:절삭가공용 의치상 레진과 직접 첨상용 레진과의 인장결합강도(2.33 ± 0.39 MPa)는 열중합형 의치상과 직접 첨상용 레진과의 인장결합강도(2.45 ± 0.39 MPa)와 통계적으로 유의성 있는 차이가 없었다 (P > .999). 적층가공한 의치상 레진과 직접 첨상용 레진과의 인장결합강도(1.23 ± 0.36 MPa)는 나머지 두 군보다 유의성 있게 낮았다 (P < .001). 열중합형과 절삭가공한 의치상에서는 혼합 파절이 가장 많이 나타났으며, 적층가공한 의치상에서는 혼합 파절과 접착 파절이 동일한 빈도로 나타났다. 결론:직접 첨상용 레진과 다양한 방법으로 제작한 의치상의 인장결합강도를 비교하였을 때 적층가공으로 제작한 의치상은 절삭가공으로 제작한 의치상, 열중합형 의치상보다 유의하게 낮은 인장결합강도를 보였다.

Adhesion of biofilm, surface characteristics, and mechanical properties of antimicrobial denture base resin

  • Ana Beatriz Vilela Teixeira;Mariana Lima da Costa Valente;Joao Pedro Nunes Sessa;Bruna Gubitoso;Marco Antonio Schiavon;Andrea Candido dos Reis
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권2호
    • /
    • pp.80-92
    • /
    • 2023
  • PURPOSE. This study incorporated the nanomaterial, nanostructured silver vanadate decorated with silver nanoparticles (AgVO3), into heat-cured resin (HT) at concentrations of 2.5%, 5%, and 10% and compared the adhesion of multispecies biofilms, surface characteristics, and mechanical properties with conventional heat-cured (HT 0%) and printed resins. MATERIALS AND METHODS. AgVO3 was incorporated in mass into HT powder. A denture base resin was used to obtain printed samples. Adhesion of a multispecies biofilm of Candida albicans, Candida glabrata, and Streptococcus mutans was evaluated by colony-forming units per milliliter (CFU/mL) and metabolic activity. Wettability, roughness, and scanning electron microscopy (SEM) were used to assess the physical characteristics of the surface. The mechanical properties of flexural strength and elastic modulus were tested. RESULTS. HT 10%-AgVO3 showed efficacy against S. mutans; however, it favored C. albicans CFU/mL (P < .05). The printed resin showed a higher metabolically active biofilm than HT 0% (P < .05). There was no difference in wettability or roughness between groups (P > .05). Irregularities on the printed resin surface and pores in HT 5%-AgVO3 were observed by SEM. HT 0% showed the highest flexural strength, and the resins incorporated with AgVO3 had the highest elastic modulus (P < .05). CONCLUSION. The incorporation of 10% AgVO3 into heat-cured resin provided antimicrobial activity against S. mutans in a multispecies biofilm did not affect the roughness or wettability but reduced flexural strength and increased elastic modulus. Printed resin showed higher irregularity, an active biofilm, and lower flexural strength and elastic modulus than heat-cured resin.

열중합(熱重合) 레진의치상(義齒床) 수리시(修理時) 파절면(破折面)에 대한 처리방법(處理方法)이 수리 후 Transverse strength에 미치는 영향(影響) (Effect of Surface Treatment on Transverse Strength of Denture Repair When Heat Cured Resin Denture Base is Repaired)

  • 정종현
    • 대한치과기공학회지
    • /
    • 제12권1호
    • /
    • pp.113-119
    • /
    • 1990
  • The purpose of this study was to investigate the effect of surface tretment on strength of denture repair as influenced by repair resin. Specimens were fabricated from VERTEX heat cured resin. Rectangular specimens($60\times10\times3mm$) were prepared according to the manufacturer's instruction for mixing and packing the resin into molds. Two methods of surface treatment were used and two methods of repair were also tested. The transverse strength of the resin was measured before repair and after repair by AUTOGRAPH testing machine. Six specimens of each category were prepared for testing for a total of 24 specimens. The mean value of the percent of recovery was calculated from the percent of recovery for six specimens. The results were as follows : 1. The mean value of the percent of recovery of each category makes a significant difference statistically one another(p<0.01), and "C" category, chloroform solvent-heat cured resin, has a better effect on repair srength than any other. 2. When no chloroform is used to treat the fractured surface there is no significant difference between the mean values of the percent of recovery influenced by the self curing resin and heat cured resin. But, when chloroform is used there is a significant difference between the two repair resins(p<0.01). 3. When self curing resin repair is used there is no significant difference between repair with and without the surface treatment of chloroform. But, when heat cured resin repair is used the use of chloroform treatment become significant statistically (p<0.01).

  • PDF

COBALT-CHROMIUM 합금의 표면처리방법에 따른 레진 의치상의 접착강도 및 표면상태에 대한 연구 (A STDUY ON THE SURFACE MORPHOLOGY AND BOND STRENGTH OF DENTURE BASE RESIN TO COBALT-CHROMIUM ALLOY AFTER VARYING MODES OF SURFACE TREATMENT)

  • 방몽숙;박영준
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.78-94
    • /
    • 1997
  • The purpose of this experiment was to determine the effects of various treatments on denture base resin to metal bond for cobalt-chromium alloy. The metal surface was treated as follows. Group 1 : Sandblasted with $50{\mu}m$ aluminum oxide. Group 2 : Sandblasted with $250{\mu}m$ aluminum oxide. Group 3 : Sandblasted with $250{\mu}m$ aluminum oxide and followed by silicoating. Group 4 : Electrochemically etched. Group 5 : treated with oxidizing solution. Group 6 : Beaded with $200{\mu}m$ retention structure and followed by silicoating. All specimens were applied with 4-META resin and were thermocycled 1000 times at temperature of $5^{\circ}C$ to $55^{\circ}C$. The effects of various surface treatments on the bond strength between 4-META resin and metal interface were measured by using the universal testing machine. All specimens were observed with SEM. The results were as follows 1. The bond strength of 4-META resin were significantly higher to Co-Cr alloy. 2. The bond strength decreased in the following orders : group 6, group 3, groups 1 and 2, group 4, group 5 and there was no statistically significant difference in bond strength among groups 1 and 2.(p>0.05) 3. The bond strength of cobalt-chromium alloy to 4-META resin were not significantly different.(p>0.05) 4. The treated surface of groups 1, 2 and 3 has more fine undercut than that of groups 4 and 5 with SEM. 5. Stable adhesion can be achieved when mechanically roughened metal surface by sandblasting than treating in an electrochemical etching and an oxidizing solution with potassium manganate.

  • PDF