• Title/Summary/Keyword: strength differences

Search Result 1,830, Processing Time 0.033 seconds

Isokinetic Muscle Strength and Muscle Endurance by the Types and Size of Rotator Cuff Tear in Men

  • Kim, In Bo;Kim, Do Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.4
    • /
    • pp.166-174
    • /
    • 2014
  • Background: Our study was to determine the effect on shoulder isokinetic muscle strength and muscle endurance in isolated full-thickness supraspinatus tendon tear and combined other rotator cuff tear. Methods: Total of 81 male patients (mean age $57.8{\pm}7.4$ years) who were diagnosed as a full-thickness supraspinatus tendon tear were included. They were classified into isolated or combined tear. The isokinetic muscle strength and muscle endurance were measured using the Biodex multi-joint system $PRO^{(R)}$ (Biodex Medical Systems, Shirley, NY, USA) in following movements: shoulder abduction, adduction, flexion, extension, external rotation, and internal rotation. Then, the difference in muscle function according to the type of tears were assessed. Fifty-seven patients had isolated supraspinatus tendon (mean age $56.9{\pm}7.3$ years). They were classified into either anteroposterior tear or modified mediolateral tear. The size were measured using T2-weighted magnetic resonance imaging scans in sagittal plane. Results: Between subjects categorized into the type of tear, we found significant inter-categorical differences in isokinetic muscle strength during abduction, adduction, flexion, extension, and internal rotation, and in muscle endurance during flexion, extension, and internal rotation. Anteroposterior diameter tear, we did not show significant differences in either isokinetic muscle strength or muscle endurance during any movements. However, with modified mediolateral diameter, we found significant differences with isokinetic muscle strength during adduction, and in muscle endurance the external rotation and internal rotation. Conclusions: We found that a supraspinatus tendon tear associated with more numbers of rotator cuff tears has lower isokinetic muscle strength and muscle endurance than a tear found alone.

DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING (의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구)

  • Choi Hoon-Dal;Kwon Kung-Rock;Kim Hyeong-Seob;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic

  • Kang, Suk-Ho;Chang, Juhea;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.134-140
    • /
    • 2013
  • Objectives: There has been a growing interest in glass ceramic systems with good esthetics, high fracture resistance and bonding durability, and simplified fabrication techniques using CAD/CAM. The aim of this study is to compare flexural strength before and after heat treatment of two lithium disilicate CAD/CAM blocks, IPS e.max CAD (Ivoclar Vivadent) and Rosetta SM (Hass), and to observe their crystalline structures. Materials and Methods: Biaxial flexural strength was tested according to ISO 6872 with 20 disc form specimens sliced from each block before and after heat treatment. Also, the crystalline structures were observed using field-emission scanning microscopy (FE-SEM, Hitachi) and x-ray diffraction (XRD, Rigaku) analysis. The mean values of the biaxial flexural strength were analyzed by the Mann-Whitney U test at a significance level of p = 0.05. Results: There were no statistically significant differences in flexural strength between IPS e.max CAD and Rosetta SM either before heat treatment or after heat treatment. For both ceramics, the initial flexural strength greatly increased after heat treatment, with significant differences (p < 0.05). The FE-SEM images presented similar patterns of crystalline structure in the two ceramics. In the XRD analysis, they also had similar patterns, presenting high peak positions corresponding to the standard lithium metasilicate and lithium disilicate at each stage of heat treatment. Conclusions: IPS e.max CAD and Rosetta SM showed no significant differences in flexural strength. They had a similar crystalline pattern and molecular composition.

Effects of Elbow Ulnar Collateral Ligament Injury on Differences in Maximal Isometric Strength of Upper body in Young Baseball Pitchers (주니어 투수들의 팔꿈치 안쪽 곁인대 손상이 상지 근육의 최대등척성수축력 차이에 미치는 영향)

  • Jang, Sehong;Kim, Donghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.628-634
    • /
    • 2016
  • Many pitchers suffer from various types of injury (distortion, sprain and so on). The rate of injury is increased if there are differences in strength between the extensor and flexor muscles when a joint movement is performed with maximum speed. However, there has been insufficient research into the injury caused by strength differences between the extensor and flexor muscles. Thus, the purpose of the study was to examine the effects of elbow ulnar collateral ligament injury on the maximal isometric strength in young baseball pitchers. The data collection was conducted for 2 weeks. The subjects (n=36) who participated in this study were placed into either the injury group (n = 18, IG) or normal group (n = 18, NG). The maximal isometric strength for the pectoralis major (PM), infraspintus (I), biceps brachii (BB), triceps brachii (TB), flexor carpi radialis (ECR) and extensor carpi radialis (FCR) muscles were determined by an isometric strength machine (K-DFX) and then the differences in strength were calculated by muscle group. All of the data were analyzed by SPSS 18.0 with the independent t-test. In the results, the maximal isometric strengths in the IG for the I (p=0.035), BB (p=0.031) and TB (p=0.041) were significantly lower than those in the NG, while that for the ECR (p=0.047) was significantly greater. In addition, the differences of the maximal isometric strength between the PM and I (p = 0.008), BB and TB (p = 0.002), and FCR and ECR (p = 0.032) in the IG were significantly greater than those in the NG. In conclusion, the differences in muscle strengths of the subjects in the IG were greater than those in the NG, which suggests that they might have a higher injury rate in the future. However, they might be able to recover from their injury and achieve better performance if the differences in strength were reduced by training.

A STUDY ON THE MARGINAL FIDELITY AND THE FRACTURE STRENGTH OF CEROMERS (수종Ceromer의 변연적합도와 파절강도에 관한 비교연구)

  • Chang Hee-Won;Lee Jong-Hyuk;Lim Heon-Song;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.438-452
    • /
    • 2005
  • Statement of problem: The use of Ceromer is increasing in dentistry. But, the research of Ceromer has not been conducted much. Purpose : This study was to evaluate the marginal fidelity and internal adaptation according to marginal position. Materials and Methods: In this study 60 resin crowns were fabricated. The measurements of the marginal fidelity were carried out using stereomicroscope $SZ-40^{(R)}$ (Olympus, Japan) and the measurements of fracture strength were done using Instron $8871^{(R)}$ (Instron Co., U.S.A.) at a cross head speed of 1mm/min. All of the measurements were statistically analyzed by ANOVA test, multiple range test and Weibull analysis. Statistical significance was set in advance at the probability level of less than 0.05. All of the measurements were analyzed with Window $SPSS^{(R)}$ Version 10.0 soft ware for the personal computer. Results : 1. There were no statistical differences of the marginal fidelity between $Targis^{(R)}$ and $Tescera^{(R)}$, but difference between these two and $BelleGlass^{(R)}$ according to materials. 2. There were no statistical differences of the marginal fidelity between no fiber group and fiber group. There were no interactions between each maerial and with/without fiber group in the marginal fidelity 3. There were statistical differences of the fracture strength between $Tescera^{(R)}$ and $BelleGlass^{(R)}$ but no statistical differences of the fracture strength between $Targis^{(R)}$ and $Tescera^{(R)}$, $Targis^{(R)}$ and $BelleGlass^{(R)}$ according to materials. 4 There were statistical differences of the fracture strength between no fiber group and fiber group. There were no interactions between each material and with/without fiber group in the fracture strength. 5. When comparing the fracture surface, no fiber group showed the resin which were fractured at the labial surface and separated from the adhesion surface. In fiber group, the fractures took a place in resin compartments. Conclusion. The marginal fidelity and the fracture strength were clinically acceptable. From these results, $Targis^{(R)}$ and $Tescera^{(R)}$ were superior than $BelleGlass^{(R)}$ in the marginal fidelity But, when applying these resin crowns in clinic, more careful consideration is needed and further study is recommended.

A STUDY ON THE PHYSICAL PROPERTIES AND COLOR STABILITY OF MAXILLOFACIAL PROSTHETIC SILICONE MATERIAL (악안면 보철용 실리콘의 물리적 특성 및 색조안정성에 관한 연구)

  • Park, Chan-Jin;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.330-343
    • /
    • 1997
  • Extraoral maxillofacial prostheses are essential for restoring facial structures that are lost as a result of congenital missing, injuries from accidents, surgical treatments of head and neck cancer. Recently, silicone is the most useful material for this purpose and is more advantageous than other maxillofacial prosthetic materials. However, there are some problems for long-term usage of silicone prostheses due to tear and color change. These are major contributing environmental factors to those problems that are such as ultraviolet light, cleansing agents, changes in humidity and successive adhesion and removal. The aim of this study is to evaluate the physical properties and color changes of maxillofacial prosthetic silicone material by those environmental factors using A-2186 silicone material (Factor II, USA) and two pigments, cadmium yellow medium and cosmetic red. Aluminium molds were fabricated according to the ASTM No. D412 & D624 specifications and resulted specimens from molds were fabicated and treated as follows. Control group and experimental I group were fabricated with 0.1% wt. pigment mixing in silicone elastomer and II-1 group, II-2 group of experimental II group were fabricated with 0.2%, 0.3% wt. pigment mixing in silicone elastomer, respectively. Control group was kept in darkroom at room temperature, I-1 group was kept under natural sunlight during 1week, I-2 group was soaked in 20% soap water during 1wk. I-3 group was successively adhered and removed 200 times on inner region of arm using Daro adhesive-33. Experimental II groups were kept in darkroom at room temperature. Instron universal testing machine was used to measure the % elongation, tensile strength, tear strength of control, experimental I, II groups and reflectance spectrophotometer(COLOR EYE-3000, Macbeth, USA) was used to measure the color differences between control group and experimental I group. The results were as follows : 1. When compared with control group, natural weathering group and 20% soap-water soaking group had no significant differences in % elongation(p>0.05). 2. 200 times successive adhesion and removal group, 0.2% wt. pigment group and 0.3% wt. pigment group had significant decreases in % elongation(p<0.05). 3. Natural weathering group, 20% soap-water soaking group and 200 times successive adhesion and removal group had no significant differences in tensile strength (p>0.05). 4. 0.2%, 0.3% wt. pigment groups had significant decreases in tensile strength(p<0.05). 5. Values of all experimental groups were decreased in tear strength. and 200 times successive adhesion and removal group had significant decrease in tear strength(p<0.05). 6. Natural weathering group and 20% soap-water soaking group had significant color differences(${\Delta}E$) and it could be detectable to naked eye(p<0.05). 7. Color differences between control group and 200 times adhesion and removal group were not detectable to the naked eye (${\Delta}E<1.0$).

  • PDF

The Influence on Ambulation of the Difference in Muscle Strength on Lower Extremity of Hemiplegic Patients (편마비 환자의 하지의 근력 차이가 보행에 미치는 영향)

  • Yoon, Jang-Soon
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.3
    • /
    • pp.47-58
    • /
    • 2005
  • The purpose of this study is to estimate how much the motility of affected and unaffected lower limb respectively would have effects on their ambulation through comparing the difference between their affected and unaffected lower limb and studying the correlation between such difference and their ambulation. In addition, the study also intends to find out remedial measures suitable for improving their ambulation with relevant physical treatment. To do this, a quantitative electromyogram(QEMG) test was done to both quadriceps and hamstring of affected and unaffected lower limb so as to yield IP values. Based on such IP values, RMS(root mean square) values as the total sum of IP values were found with QEMG analysis system (made by Medelec Co.) and then the ambulation depending on the difference in muscular strength were analyzed by ink-foot print method as well as the corresponding statistics were processed by T-test through SPSS. The effect of differences in muscular strength of quadriceps in affected and unaffected limb of hemiplegic patients on their ambulation was also different in each element of ambulation. However, there was not any statistically significant difference (p>.05). The differences in muscular strength of hamstring in unaffected limbs of hemiplegic patients only affect stride length. It was statistically significant. The effect of difference in muscular strength of the hamstring in affected limb of hemiplegic patients on their ambulation was very different between strong and weak group in terms of walking velocity, step per minute, stride and step length, showing statistically significant difference(p<.05). Although there was a difference in the step length of the affected limb, it was not statistically significant(p>.05). For the unaffected hamstring, there were significant differences of stride length between in unaffected limb and in affected limb. For the affected hamstring, there were also significant differences in walking velocity, step per minute, stride and step length. Besides, it was found that the difference of the muscular strength between strong and weak group was at the highest. Thus, the effect of difference in muscular strength on ambulatory factors such as walking velocity, step per minute, stride and step length did not show any statistical significance but differences in affected and unaffected quadriceps. However, it was found that both the difference of stride in unaffected hamstring and the difference of all ambulatory factors except from step length with affected limb had effects on ambulation depending upon muscular strength.

  • PDF

The Effect of Short-term Lumbar Stabilization Exercise for Lumbar Muscle Strength and Postural Balance on Chronic LBP (단기간의 요부안정화 운동이 만성요통환자의 근력과 자세균형에 미치는 영향)

  • Cho, Sung-Hak;Kim, Jin-Heem;Choi, Mun-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.3
    • /
    • pp.295-302
    • /
    • 2013
  • PURPOSE: The purpose of this study was to investigate the effect of short-term lumbar stabilization exercise to patients suffering from chronic low back pain(CLBP) on the strength of their lumbar flexor and extensor and the postural balance of them and to suggest effective treatment duration for them. METHODS: Study subjects were 20 patients with CLBP who's been reported the pain for more than 12 weeks. For these subjects, muscle strength of both extensor and flexor of lumbar and the balancing ability were measured before and after the intervention. Lumbar stabilization exercise was composed of matt, ball and sling exercise. The intervention was applied for total 12 sessions for 4 weeks (3 times a week) and each session was for 40 minutes. RESULT: For muscle strength of both extensor and flexor of lumbar, there was significant differences after the application of lumbar stabilization exercise(p<.05). For balancing ability, stabilization shows significant differences in all of the positions except PC(eyes closed on pillows)(p<.05). Distribution of weight shows no significant differences but it was generally distributed within normal range after the exercise and Fall index shows significant differences between before and after the exercise(p<.05). CONCLUSION: These results could have positive effect on deciding different periods of therapeutic intervention.

The Influence of Bonding Strength and Interface Characteristics to Bonding Agent and Veneer Ceramics on Metal-Ceramic Prosthetics (결합재와 베니어세라믹이 금속-세라믹 보철물의 전단결합강도와 계면특성에 미치는 영향)

  • Kim, Min-Jung;Choi, Sung-Min;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.349-357
    • /
    • 2011
  • Purpose: In this study, for the reasons of observing the changes when using bonding agent with Ni-Cr alloy and Co-Cr alloy and using VM13 and Vintage MP ceramic which have the disparity in coefficient of thermal expansion, it is carried out to evaluate the characteristics of the bonding agent through the analysis of the interface between metal and ceramic and the analysis of bond strength by variable. Methods: The surface treatment was performed on the two kinds of alloy(Ni-Cr alloy and Co-Cr alloy) specimens, which were sandblasted and were treated with bonder application. The metal-ceramic interfaces were analyzed with EPMA in order to ionic diffusion, and the shear test was performed. Results: As a result of observation of metal-ceramic interfacial properties, it was observed that Cr atoms were spread from the alloy body to the ceramic floor in the specimen of Group B. It was also seen that Cr, W atoms were spread from the alloy body to the ceramic floor in the specimen of Group S. In consequence of observing Shear bond strength, it was calculated that the specimen of BSV was 27.75(${\pm}11.21$)MPa, BSM was 27.02(${\pm}5.23$)MPa, BCV was 30.20(${\pm}5.99$)MPa, BCM was 27.94(${\pm}10.76$)MPa, SSV was 20.83(${\pm}2.58$)MPa, SSM was 23.98(${\pm}3.94$)MPa, SCV was 32.32(${\pm}4.68$)MPa, and SCM was 34.54(${\pm}10.63$)MPa. Conclusion: In the metal-ceramic interface of Bellabond plus sample group, diffusion of Cr atoms was incurred and diffusion of C Cr atoms and W atoms in the sample group of $Starloy{(R)}\;C$ was observed. Using bonding agent showed the higher bond strength than using the sand blasting treatment. In the Bellabond plus alloys, the specimen group with the use of binding materials showed higher shear bond strength, but didn't show statistically significant differences (p>0.05). In the $Starloy{(R)}\;C$ alloys, the specimen group with the use of binding materials showed higher shear bond strength and statistically significant differences(p<0.05). In terms of VM13 ceramic, it was in the Bellabond plus alloys that the high shear bond strength was showed, but there's no statistically significant differences(p>0.05). In terms of Vintage MP ceramic, it was in the $Starloy{(R)}\;C$ alloys that the high shear bond strength was showed and statistically significant differences(p<0.05). Metal-ceramic to fracture of the shear strength measurements and an analysis of all aspects of military usage fracture of the composite, respectively.

The Effects of Body Blade and Thera Band Exercise in Upper Extremity Muscle Strength, Grip Strength and Balance in University Students (바디블레이드와 세라밴드를 이용한 운동이 대학생의 상지근력 악력 및 균형에 미치는 영향)

  • Jo, Min-hyung;Kim, Dong-ho;Kim, In-ha;Lee, Seung-hee;Kim, Sun-kyo;Kim, Young-joo;Choi, Ban-seok;Lee, So-young;Cho, Eui-jin;Kim, Eun-jung;Choi, Hyo-jung;Lim, Kwang-mook;Lee, Yoo-jin;Kim, Kyung-hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.1
    • /
    • pp.22-34
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effects of body blade and Thera band exercise on upper extremity strength, grip strength and balance of university students. Design: Single Blind Randomized Controlled Trial. Method: twenty healthy adults, participated in this study, and were recruited by G University in Gimcheon Korea. The subjects were randomly divided into A group that went through Thera band exercise and B group that went through Body blade exercise. Each group had 10 subjects. All subjects did the experiment for 3 times a week for 3weeks. Spss was used for statistical analysis. Result: 1) Grip strength: After exercising, for the BE group, there were statistically significant differences in dominant and non-dominant hand. However, for the TE group, there were no significant statistical differences in both hands. 2) muscle strength: In the TE group there were no significant statistical differences in the dominant and non-dominant arm. But in the BE group there were differences which were found. 3) balance: After exercising, both groups had no significant statistical difference in medial lateral balance. In anterior and posterior balance, TE group had no statistical significant difference but BE group did. Conclusion: To improve muscle strength balance and grip strength, body blade exercise is more effective than Thera band exercise.