• Title/Summary/Keyword: strength decay

Search Result 107, Processing Time 0.026 seconds

Probabilistic seismic performance evaluation of non-seismic RC frame buildings

  • Maniyar, M.M.;Khare, R.K.;Dhakal, R.P.
    • Structural Engineering and Mechanics
    • /
    • v.33 no.6
    • /
    • pp.725-745
    • /
    • 2009
  • In this paper, probabilistic seismic performance assessment of a typical non-seismic RC frame building representative of a large inventory of existing buildings in developing countries is conducted. Nonlinear time-history analyses of the sample building are performed with 20 large-magnitude medium distance ground motions scaled to different levels of intensity represented by peak ground acceleration and 5% damped elastic spectral acceleration at the first mode period of the building. The hysteretic model used in the analyses accommodates stiffness degradation, ductility-based strength decay, hysteretic energy-based strength decay and pinching due to gap opening and closing. The maximum inter story drift ratios obtained from the time-history analyses are plotted against the ground motion intensities. A method is defined for obtaining the yielding and collapse capacity of the analyzed structure using these curves. The fragility curves for yielding and collapse damage levels are developed by statistically interpreting the results of the time-history analyses. Hazard-survival curves are generated by changing the horizontal axis of the fragility curves from ground motion intensities to their annual probability of exceedance using the log-log linear ground motion hazard model. The results express at a glance the probabilities of yielding and collapse against various levels of ground motion intensities.

Risk Assessment by Toluene Source Emission Model in Indoor Environments of New Houses (신축 주택의 톨루엔 발생량 모델을 이용한 건강위해성 평가)

  • Kim, Young-Hee;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.398-403
    • /
    • 2006
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.

A Research Trend on Space Charge Analysis in Polymer Irradiated by Electron Beam (온도 상승시에 전자빔 조사된 폴리머내의 전하 분포의 축퇴 현상 연구 동향)

  • Ko, Sung-Min;Kim, Nam-Yong;Kim, Dae-Yeol;Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1992-1993
    • /
    • 2007
  • Decay processes of accumulated charge in e-beam irradiated polymers during elevating temperature are observed using pulsed electro-acoustic measurement system. Since the polymeric materials have many superior properties such as light-weight, good mechanical strength, high flexibility and low cost, they are inevitable materials for spacecrafts. In space environment, however, the polymers sometimes have serious damage by irradiation of high energy charged particles. When the polymers of the spacecraft are irradiated by high energy charged particles, some of injected charges accumulate and remain for long time in the bulk of the polymers. Since the bulk charges sometimes cause the degradation or breakdown of the materials, the investigation of the charging and the decay processes in polymeric materials under change of temperature is important to decide an adequate material for the spacecrafts. By measuring the charge behavior in e-beam irradiated polymer, such as polyimide or polystyrene, it is found that the various accumulation and decay patterns are observed in each material. The results seem to be useful and be helpful to progress in the reliability of the polymers for the spacecraft.

  • PDF

Decay Damage of Japanese Larch(Larix leptolepis) Caused by Two Butt-Rot Fungi, Phaeolus schweinitzii and Sparassis crispa (해면버섯균(菌) 꽃송이버섯균(菌)에 의(依)한 낙엽송 생입목(生立木)의 심재부후피해(心材腐朽被害))

  • Kim, Hyun Joong;Kim, Jun Suob;Yi, Chang Keun
    • Journal of Korean Society of Forest Science
    • /
    • v.79 no.2
    • /
    • pp.138-143
    • /
    • 1990
  • In mature stand of Japanese larch (Larix leptolepis(S. et Z.) Gordon) planted in 1925, heartrot damage was investigated by felling some infected trees with fruit bodies of two butt-rot fungi, Phaeolus schweinitzii and Sparassis crispa. Percentage of heartrot area on basal area of decay trees was 19.2-74.4, and the height reached by the decay was 1.2-5.5m. Percentage of decay volume was in the range of 2.2-13.4%, but the loss wood to the height reached by the decay amounted to 27.2% (range 13.1-37.1%) of whole volume, Decay damage caused by S. crispa was much greater than that caused by P. schweinitzii. Compressive strength ($52-77kg/cm^2$) and specific gravity (0.40-0.47) of rot wood was reduced to 77% and 39% respectively in maximum as compared to sound wood of healthy tree, and those of sound-looking wood close by heartrot to 42% and 26%. The current annual growth of trees with decay was fallen behind that of sound tree from eight to fourteen years after planting in D. B. H. and from twelve to twenty-one years after in volume.

  • PDF

The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가)

  • 이병성;송일근;이재봉;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

Designing a Hydro-Structural Ship Model to Experimentally Measure its Vertical Bending and Torsional Vibrations

  • Houtani, Hidetaka;Komoriyama, Yusuke;Matsui, Sadaoki;Oka, Masayoshi;Sawada, Hiroshi;Tanaka, Yoshiteru;Tanizawa, Katsuji
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.4
    • /
    • pp.174-184
    • /
    • 2018
  • We herein propose a new design procedure of a flexible container ship model where the vertical bending and torsional vibration modes are similar to its prototype. To achieve similarity in torsional vibration mode shapes, the height of the shear center of the model must be located below the bottom hull, similar to an actual container ship with large opening decks. Therefore, we designed a ship model by imparting appropriate stiffness to the hull, using urethane foam without a backbone. We built a container ship model according to this design strategy and validated its dynamic elastic properties using a decay test. We measured wave-induced structural vibrations and present the results of tank experiments in regular and freak waves.

Sensitivity analysis of flexural strength of RC beams influenced by reinforcement corrosion

  • Hosseini, Seyed A.;Shabakhty, Naser;Khankahdani, Fardin Azhdary
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.479-489
    • /
    • 2019
  • The corrosion of reinforcement leads to a gradual decay of structural strength and durability. Several models for crack occurrence prediction and crack width propagation are investigated in this paper. Analytical and experimental models were used to predict the bond strength in the period of corrosion propagation. The manner of flexural strength loss is calculated by application of these models for different scenarios. As a new approach, the variation of the concrete beam neutral axis height has been evaluated, which shows a reduction in the neutral axis height for the scenarios without loss of bond. Alternatively, an increase of the neutral axis height was observed for the scenarios including bond and concrete section loss. The statistical properties of the parameters influencing the strength have been deliberated associated with obtaining the time-dependent bending strength during corrosion propagation, using Monte Carlo (MC) random sampling method. Results showed that the ultimate strain in concrete decreases significantly as a consequence of the bond strength reduction during the corrosion process, when the section reaches to its final limit. Therefore, such sections are likely to show brittle behavior.

Evaluation Method for Improvement Efficiency of Indoor Air Quality in Residence (주택의 실내공기질 개선 평가 방법)

  • Yang, Won-Ho;Son, Bu-Soon;Yim, Sung-Kuk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.255-263
    • /
    • 2007
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. The purposes of this study were to evaluate the alternative method for improvement of indoor air quality in house after coating titanium dioxide ($TiO_2$) photocatalyst for interior part of the house using nitrogen dioxide ($NO_2$) multiple measurements. To evaluate the alternative method in indoor environment, daily indoor and outdoor $NO_2$ concentrations of an apartment and a detached house were daily measured for consecutive 21 days in winter and summer, respectively, Another daily 21 measurements were carried out after $TiO_2$ coating on wall paper of interior part in houses. All $NO_2$ concentrations were measured by passive filter badges. Indoor air quality models using mass balance are useful tool to quantify the relationship between indoor air pollution levels, ambient concentrations, and explanatory variables. Using a mass balance model and linear regression analysis, penetration factor (ventilation rate divided by sum of ventilation rate and decay rate) and source strength factor (emission rate divided by sum of ventilation rate and decay rate) were calculated. Subsequently, the decay constants were estimated. In this study. magnitude of improvement of indoor air quality could be evaluated by decay constant.

Estimation of Source Strength and Deposition Constant of Nitrogen Dioxide Using Compartment Model (구획모델을 이용한 주택에서 이산화질소의 발생강도 및 감소상수 동시 추정)

  • Yang Won-Ho;Son Bu-Soon;Sohn Jong-Ryeul
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.260-265
    • /
    • 2005
  • Indoor air quality might be affected by source strength of indoor pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate the source strength and deposition constant by application of multiple measurements. For the total duration of 60 days, indoor and outdoor $NO_2$ concentrations every 3 days were measured in 30 houses in Seoul, Asan and Daegu. Using a compartment model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the source strength and deposition constant were estimated. Natural ventilation was $1.80{\pm}0.42\;ACH,\;1.11{\pm}0.50\;ACH,\;0.92{\pm}0.26\;ACH$ in Seoul, Asan and Daegu, respectively. Calculated deposition constant(K) and source strength of $NO_2,$ in this study were $0.98{\pm}0.28\;hr^{1}\;and\;16.28{\pm}7.47\;ppb/h,$ respectively.

Tensile Properties of Hybrid Fiber-Reinforced Reactive Powder Concrete After Exposure to Elevated Temperatures

  • Li, Haiyan;Liu, Gang
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • The paper presents a research project on the tensile properties of RPC mixed with both steel and polypropylene fibers after exposure to $20-900^{\circ}C$. The direct and the indirect tensile strength (in bending) were measured through tensile experiment on dog-bone specimens and bending experiment on $40{\times}40{\times}160mm$ prisms. RPC microstructure was analyzed using scanning electron microscope. The results indicate that, steel fibers can significantly improve the tensile performance of hybrid fiber-reinforced RPC, whereas polypropylene fibers have no obvious effect on the tensile performance. With increasing temperature, the flexural and axial tensile strength of hybrid fiber-reinforced RPC substantially decrease linearly, which attributes to the deteriorating microstructure. Based on the experimental results, equations are established to express the decay of the flexural and tensile strength with increasing temperature.